Casio QT 6000 Service Manual - Page 32

DIAG command input system, 4. Status Display, However, when performing a test

Page 32 highlights

7-3. DIAG command input system Input a command according to the following code. XXXXXXn a g d XXXXXX : additional action n : number of times a : action g : group d : device number 7-4. Status Display With the EX820, the following display is displayed on the LCD (SVGA). (In this DIAG, the display area is divided into a display for register entry and a display of DIAG results and so forth. DALLAS DRW1 CLOSE 0000 MENU SHEET 1 DRW2 CLOSE CLR ESC 7 8 9 4 5 6 1 2 3 0 ST [Functions] Status is displayed for those devices having status information. The devices and status displayed are as shown below. Device Status Information (Displayed Information) Dallas key Dallas key no. Dallas key 2 Drawer Dallas key no. Open/close status MAC address MAC address CF Insertion status DISP ON/OFF switch Switch status TEMP Poxwer supply A/D conversion value * Display only updated when DISP ON/OFF switch is ON [LCD Display] MAC ADRS XX-XX-XX-XX-XX-XX CF INSERT DISP ON/OFF ON TEMP 20 Status information is displayed continuously (in ordinary characters). However, when performing a test, the status at completion of a test is displayed following completion of that test. Diag Ver : XXXXXX XXXX DALLAS DRW1 CLOSE 0000 DRW2 CLOSE 1234 Register: Characters enlarged 1.5 times (max. 10 digits) Counter display * Addition of TEMP information and DISP ON/OFF status The TEMP status is acquired preferentially when the DISP ON/OFF switch is ON. When measuring other status information or when starting each test mode, always make sure to begin after switching off the DISP ON/OFF switch. - 30 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154

— 30 —
7-3. DIAG command input system
Input a command according to the following code.
X
X
X
X
X
X
n
a
g
d
XXXXXX : additional action
n : number of times
a : action
g : group
d : device number
7-4. Status Display
With the EX820, the following display is displayed on
the LCD (SVGA).
(In this DIAG, the display area is
divided into a display for register entry and a display
of DIAG results and so forth.
ESC
CLR
7
8
9
4
5
6
1
2
3
0
ST
DALLAS
DRW1 CLOSE
MENU SHEET 1
DRW2 CLOSE
0000
[Functions]
Status is displayed for those devices having status information.
The devices and status displayed
are as shown below.
Device
Status Information (Displayed Information)
Dallas key
Dallas key no.
Dallas key 2
Dallas key no.
Drawer
Open/close status
MAC address
MAC address
CF
Insertion status
DISP ON/OFF switch
Switch status
TEMP
Poxwer supply A/D conversion value
* Display only updated when DISP ON/OFF switch is ON
DALLAS
DRW1 CLOSE
MAC ADRS
XX-XX-XX-XX-XX-XX
CF INSERT
DISP ON/OFF
ON
TEMP 20
Diag Ver
:
XXXXXX
XXXX
DRW2 CLOSE
0000
1234
Status information is displayed continuously (in ordinary characters).
However, when performing a test, the status at completion of a test is
displayed following completion of that test.
Register: Characters enlarged 1.5 times (max. 10 digits)
Counter display
[LCD Display]
*
Addition of TEMP information and DISP ON/OFF status
The TEMP status is acquired preferentially when the DISP ON/OFF switch is ON.
When measuring
other status information or when starting each test mode, always make sure to begin after switching
off the DISP ON/OFF switch.