Casio QT 6000 Service Manual - Page 41

] Remote Cust DISP test, REMOTE DISP]

Page 41 highlights

[ 14 ] Remote Cust DISP test [Function] This test will check whether REMOTE DISP can be displayed. Make sure to connect REMOTE DISP to COM3. In case of one time check only, the test can be ended by the judgment (OK or NG) of the operator. Pastel green (white plus green) appears as the backlight, which turns off upon the end of the test. * When changing the baud rate, make sure to change the REMOTE DISP setting. [Operation] Press [OK] key or [NG] key to end the test when performing one time check. "OK" = 1, "NG" = 9 Operation : b n 0 2 3 ST b: Baud rate selection 0 = 19.2 Kbps, 1 = 9600 bps n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) When performing continuous check, the same test character data is sent at a certain interval. When the test is ended manually upon the input of [ESC] key, the display is cleared and the backlight turns off. In case of one time check, the display is cleared and the backlight turns off after the judgment ([OK] or [NG]) of the operator. [LCD] REMOTE DISP REMOTE DISP END na23 OK na23 [REMOTE DISP] ABCDEFGHIJKLMNOP QRSTUVWXYZabcdef 0,1,2,3,4,5,6,7,8,9, [PRINT] REMOTE DISP REMOTE DISP END na23 OK na23 - 39 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154

— 39 —
[ 14 ] Remote Cust DISP test
[Function]
This test will check whether REMOTE DISP can be displayed.
Make sure to connect REMOTE DISP to COM3.
In case of one time check only, the test can be ended by the judgment (OK or NG) of the operator.
Pastel green (white plus green) appears as the backlight, which turns off upon the end of the test.
* When changing the baud rate, make sure to change the REMOTE DISP setting.
[Operation]
Press [OK] key or [NG] key to end the test when performing one time check.
"OK" = 1, "NG" = 9
Operation :
b
n
0
2
3
ST
b:
Baud rate selection
0 = 19.2 Kbps, 1 = 9600 bps
n:
0 = One time check (can be omitted)
not 0 = Continuous check (To stop the test, press "ESC" key)
When performing continuous check, the same test character data is sent at a certain interval. When
the test is ended manually upon the input of [ESC] key, the display is cleared and the backlight turns
off.
In case of one time check, the display is cleared and the backlight turns off after the judgment ([OK]
or [NG]) of the operator.
[LCD]
REMOTE DISP
na23
REMOTE DISP
OK
END
na23
REMOTE DISP
na23
REMOTE DISP
OK
END
na23
[REMOTE DISP]
ABCDEFGHIJKLMNOP
QRSTUVWXYZabcdef
0,1,2,3,4,5,6,7,8,9,
[PRINT]