Casio QT 6000 Service Manual - Page 48
] Time setting / [ 22 ] Time display, 23 ] Drawer open test
View all Casio QT 6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
[ 21 ] Time setting / [ 22 ] Time display [Function] This sets the time and date. When setting the time, the time and date will be displayed without inputting the fixed value. [Operation] * Date and time setting Operation : x1 x2 x3 x4 x5 x6 0 a 7 0 ST a: 0: time setting x1/x2: time, x3/x4: minutes, x5/x6: second 1: time setting x1/x2: year, x3/x4: month, x5/x6: day The test will be done one time. * Date and time display Operation : 7 0 ST To stop the operation, press "ESC" key. [LCD] DATE/TIME DATE/TIME END 70 YY/MM/DD HH:MM-SS 70 Each data will be printed only when setting the date and time. [PRINT] DATE/TIME DATE END YYMMDD0170 YY/MM/DD YYMMDD0170 [ 23 ] Drawer open test [Function] This test will check the drawer open function. The test ends by the judgment of the operator either by OK or NG only when the one time check is selected. [Operation] Operation : x n 0 9 1 ST x: 0 = All drawers open (can be omitted), 1 = Drawer 1 open, 2 = Drawer 2 open n: 0 = One time check (can be omitted) not 0 = Continuous check (To stop the test, press "ESC" key) * When the continuous check is selected, the drawer opens every 2 seconds. * The following "OK" or "NG" key can be used in case of one time check. "OK" = 1, "NG" = 9 [LCD] The status signal from the drawers appears in the status display position of the LCD. In case of continuous check as well as when all drawers are open, the status appears after all the drawers open. [PRINT] DRW DRW ALL END xn091 OK xn091 DRW DRW ALL END xn091 OK xn091 - 46 -