Cisco ATA188-I2-A Administration Guide - Page 121
Cadence with Three On-Off Pairs, to the order
View all Cisco ATA188-I2-A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 121 highlights
Chapter 5 Parameters and Defaults Tone Configuration Parameters • TFreq1, TFreq2, and TFreq3 are the transformed frequencies of the first, second, and third frequencies, respectively. Calculate each value with the following formula: 32767 * cos (2 * pi * F/8000) where F is the desired frequency in Hz. Set this value to 0 if the frequency does not exist. The range of each value is -32768 to 32767. For negative values, use the 16-bit 2's complement value. For example, enter -1 as 65535 or as 0xffff. • Tamp1, Tamp2 and Tamp3 are the transformed amplitudes of the first, second and third frequencies, respectively. Their values are calculated with the following formula: 32767 * A * sin(2*pi*F/8000) A (amplitude factor) = 0.5 * 10^((k+10-(n-1)*3)/20) where F is the desired frequency in Hz, k is the desired volume in dBm, and n is the number of frequencies (If Sequential is set to 101, n is equal to 1). The ^ symbol means to the order of. • NumOfOnOffPairs is the number of on-off pairs in the cadences of the tone (0, 1, 2, or 3). For a steady tone, use 0. If this value is 0, the OnTime1, OnTime2, OnTime 3, OffTime1, OffTime2, and OffTime3 values must also be 0. • OnTime1, OnTime2, and OnTime3 are the lengths of time that the first, second, and third on-off pairs of a cadence play a sound, respectively. (See Figure 5-2 for a graphical representation.) Specify each value as a number of samples with the sampling rate of 8 kHz. The range of each value is 0 to 0xffff. For example, for a length of 0.3 seconds, set a value to 2400. • OffTime1, OffTime2, and OffTime3 are the lengths of silence after the sound of the first, second, and third on-off pairs of a cadence, respectively. Specify each value as a number of samples with the sampling rate of 8 kHz. The range of each value is 0 to 0xffff. For example, for a length of 0.3 seconds, set a value to 2400. (See Figure 5-2 for a graphical representation.) Figure 5-2 Cadence with Three On-Off Pairs Sound OnTime_1 OnTime_2 OnTime_3 99267 Silence OffTime_1 OffTime_2 OffTime_3 • NumOfRepeats is the number of times that the first on-off pair of the cadence (specified by OnTime1, OffTime1) repeats before the second on-off pair (specified by OnTime2, OffTime2) plays. For example, if NumOfRepeats is 2, the first on-off pair will play three times (it will play once and then repeat two times), then the second on-off pair will play. • TotalToneTime is the total length of time that the tone plays. If this value is 0, the tone will play until another call event stops the tone. This value is in 10 ms units (100 ms = 1 second). OL-4804-01 Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator's Guide for H.323 (version 3.0) 5-45