Epson WorkForce Pro GT-S80 User Manual - Page 105

Electrical, Environmental, Scanner, GT-S80, AC Adapter, 240 V model

Page 105 highlights

Weight Approx. 10.1 lb (4.6 kg) Top Electrical Note: Check the label on the AC adapter or on the back of the scanner for voltage information. Scanner Rated voltage Rated input current Power consumption AC Adapter Operating mode Ready mode Sleep mode Power off mode AC adapter model Rated input voltage Rated input current Rated input frequency Rated output voltage Rated output current Note: The AC adapter model varies in certain locations. GT-S80 45 W DC 24.0 V 2.0 A 13 W 4.2 W 1 W GT-S50 40 W 100-240 V model A421H AC 100 to 240 V 1.2 A 50 to 60 Hz DC 24.0 V 2.0 A Top Environmental Temperature Humidity Operating conditions Operating Storage Operating Storage 50 to 95 ˚F (10 to 35 ˚C) -13 to 140 ˚F (-25 to 60 ˚C) 10 to 80%, without condensation 10 to 85%, without condensation Ordinary office or home conditions. Avoid operating the scanner in direct sunlight, near a strong light source, or in extremely dusty conditions.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

Weight
Approx. 10.1 lb (4.6 kg)
Top
Electrical
Note:
Check the label on the AC adapter or on the back of the scanner for voltage information.
Scanner
GT-S80
GT-S50
Rated voltage
DC 24.0 V
Rated input current
2.0 A
Power consumption
Operating mode
45 W
40 W
Ready mode
13 W
Sleep mode
4.2 W
Power off mode
1 W
AC Adapter
100-240 V model
AC adapter model
A421H
Rated input voltage
AC 100 to 240 V
Rated input current
1.2 A
Rated input frequency
50 to 60 Hz
Rated output voltage
DC 24.0 V
Rated output current
2.0 A
Note:
The AC adapter model varies in certain locations.
Top
Environmental
Temperature
Operating
50 to 95 ˚F (10 to 35 ˚C)
Storage
–13 to 140 ˚F (–25 to 60 ˚C)
Humidity
Operating
10 to 80%, without condensation
Storage
10 to 85%, without condensation
Operating conditions
Ordinary office or home conditions.