HP Cisco MDS 9020 Cisco MDS 9000 Family System Messages Reference (OL-15956-01 - Page 443
affected module., Compact Flash CRC checksum initializations failed.
View all HP Cisco MDS 9020 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 443 highlights
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family Send documentation comments to [email protected] Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_CRC_INIT_ERRORS: Compact Flash firmware CRC checksum procedure encountered an error during initialization on module [dec] Reason: [chars]. Explanation Compact Flash CRC checksum initializations failed. Recommended Action Check the compact flash on the board and any relevant system(mis) configurations. Introduced Cisco MDS SAN-OS Release 3.1(3). Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_CRC_INTERN_ERRORS: Compact Flash firmware CRC checksum procedure cannot proceed due to internal errors on module [dec]. Explanation Compact Flash CRC checksum procedure was terminated due to internal errors. Recommended Action Restarting the cf-crc-check using system health clear-errors module cf-crc-check. If the condition persists, schedule a downtime and replace the compact flash on the affected module. Introduced Cisco MDS SAN-OS Release 3.1(3). Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_RECALLED: Compact Flash on module [dec] is healthy at this time. But this has been identified a recalled part. Please replace it soon since it can go bad anytime. Explanation Compact Flash model has data retention issues and needs to be replaced. Recommended Action Schedule a downtime and replace the compact flash on the affected module. Introduced Cisco MDS SAN-OS Release 3.1(3). Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_UNRESPONSIVE: Recalled Compact Flash on module [dec] is unresponsive. Explanation The compact flash model has data retention issues and needs to be replaced. Recommended Action Schedule a downtime and replace the compact flash on the affected module. Introduced Cisco MDS SAN-OS Release 3.1(3). Error Message SYSTEMHEALTH-4-OHMS_SUP_CF_REFLASH_INTERN_ERRORS: Compact Flash firmware re-flash procedure cannot proceed due to internal errors on module [dec]. Explanation Compact Flash firmware reflash procedure terminated due to internal errors. Recommended Action Restarting the test using system health clear-errors module cf-re-flash. If the condition persists, schedule a downtime and replace the compact flash on the affected module. Introduced Cisco MDS SAN-OS Release 3.3(1a). OL-15956-01 Cisco MDS 9000 Family System Messages Reference 2-407