HP Cisco MDS 9020 Cisco MDS 9000 Family System Messages Reference (OL-15956-01 - Page 467
VHBAD-3, show process cpu, show system internal sysmgr service all, show flash, VSAN_get_global_value
View all HP Cisco MDS 9020 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 467 highlights
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family Send documentation comments to [email protected] Error Message VHBAD-2-PROC_WWNM_GET_WWN_FAIL: Failed to get local controller pwwn from WWN Manager error: [hex] response: [hex]. Explanation SCSI target process used the wwnm_bwt_get_local_controller_wwn() API for the port WWN and it failed because of the error and response code shown in the error message. No SCSI discovery can be performed. Recommended Action Enter the show process cpu and show system internal sysmgr service all CLI commands or use a similar Fabric Manager/Device Manager procedure to collect more information. See the WWN manager system error codes for the reason. Introduced Cisco MDS SAN-OS Release 1.2(2a). VHBAD-3 Error Message VHBAD-2-PSS_INIT_FAIL: pss initialization failed due to error: [hex]. Explanation SCSI target process persistent storage service (PSS) initialization failed because of the error shown in the error message. No SCSI discovery can be performed. Recommended Action Enter the show flash CLI command or use a similar Fabric Manager/Device Manager procedure to collect more information. See PSS system error codes for the reason. Introduced Cisco MDS SAN-OS Release 1.2(2a). Error Message VHBAD-3-PROC_VSAN_GET_RATOV_FAIL: Failed to get VSAN attribute RATOV from VSAN Manager, error: [hex]. Explanation SCSI target process used the VSAN_get_global_value() API for RATOV and it failed because of the error shown in the error message. Recommended Action This is a non-fatal error. The default value for RATOV is used. Enter the show process cpu and show system internal sysmgr service all CLI commands or use a similar Fabric Manager/Device Manager procedure to collect more information. See the VSAN Manager system error codes for reason. Introduced Cisco MDS SAN-OS Release 1.2(2a). Error Message VHBAD-3-PSS_CREATE_FAIL: pss create runtime database failed due to error: [hex]. Explanation SCSI target process persistent storage service (PSS) create runtime database failed because of the error shown in the error message. No SCSI discovery can be performed. Recommended Action Enter the show flash CLI command or use a similar Fabric Manager/Device Manager procedure to collect more information. See PSS system error codes for the reason. Introduced Cisco MDS SAN-OS Release 1.2(2a). OL-15956-01 Cisco MDS 9000 Family System Messages Reference 2-431