Appendix D Technical Specifications Switch Specifications Send documentation comments to [email protected]. Table D-3 Physical Specifications for the Cisco MDS 9509 Director (continued) Description Specification Power supply Airflow 4000-W, AC input 3000-W, AC input 2500-W, AC input 2500-W, DC input 300 lfm2 through system fan module, or 80 cfm3 per supervisor, switching, or services module. Total of 720 cfm if all slots are filled. Spacing requirements: • If installed in a cabinet, a minimum clearance of 2.5 in. (6.4 cm) is required between the chassis air vents and the cabinet walls. • If installed in an open rack (no side panels), the horizontal distance required between the chassis and any devices that exhaust air towards the chassis is a minimum of 6 in. (15.2 cm), and the distance required between the chassis air vents and any walls is a minimum of 2.5 in. (6.4 cm). 1. RU = rack unit; 1 RU = 1.75 in. (4.45 cm) 2. lfm = linear feet per minute 3. cfm = cubic feet per minute Table D-4 lists the physical specifications for the Cisco MDS 9506 Director. Table D-4 Physical Specifications for the Cisco MDS 9506 Director Description Dimensions (HxWxD) Weight Specification 12.25 x 17.37 x 21.75 in. (31.1 x 44.1 x 55.2 cm). Chassis requires 7 RU1. Chassis depth including cable guides is 26.75 inches (67.9 cm). Chassis only: 46 lb (20.9 kg). Chassis configured with two supervisor modules, fan module, and two power supplies: 86 lb (39 kg). System fan tray: 7.70 lbs (3.49 kg) 1900W AC power supply: 11 lbs (4.99 kg) OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide D-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288

Send documentation comments to [email protected].
D-3
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Appendix D
Technical Specifications
Switch Specifications
Table D-4
lists the physical specifications for the Cisco MDS 9506 Director.
Power supply
4000-W, AC input
3000-W, AC input
2500-W, AC input
2500-W, DC input
Airflow
300 lfm
2
through system fan module, or 80 cfm
3
per supervisor,
switching, or services module. Total of 720 cfm if all slots are
filled.
Spacing requirements:
If installed in a cabinet, a minimum clearance of 2.5 in.
(6.4 cm) is required between the chassis air vents and the
cabinet walls.
If installed in an open rack (no side panels), the horizontal
distance required between the chassis and any devices that
exhaust air towards the chassis is a minimum of 6 in.
(15.2 cm), and the distance required between the chassis air
vents and any walls is a minimum of 2.5 in. (6.4 cm).
1.
RU = rack unit; 1 RU = 1.75 in. (4.45 cm)
2.
lfm = linear feet per minute
3.
cfm = cubic feet per minute
Table D-3
Physical Specifications for the Cisco MDS 9509 Director (continued)
Description
Specification
Table D-4
Physical Specifications for the Cisco MDS 9506 Director
Description
Specification
Dimensions
(HxWxD)
12.25 x 17.37 x 21.75 in. (31.1 x 44.1 x 55.2 cm).
Chassis requires 7 RU
1
.
Chassis depth including cable guides is 26.75 inches (67.9 cm).
Weight
Chassis only: 46 lb (20.9 kg).
Chassis configured with two supervisor modules, fan module,
and two power supplies: 86 lb (39 kg).
System fan tray: 7.70 lbs (3.49 kg)
1900W AC power supply: 11 lbs (4.99 kg)