HP Cisco MDS 9020 Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 28

Cisco MDS 9509 Director

Page 28 highlights

Chassis Chapter 1 Product Overview Send documentation comments to [email protected]. Cisco MDS 9509 Director The Cisco MDS 9509 Director has a 9-slot chassis as shown in Figure 1-3, and it supports the following: • Redundant Supervisor-2 modules with associated internal crossbar modules. • Up to two Supervisor-1 modules that provide a switching fabric, plus a console port, COM1 port, and a MGMT 10/100 Ethernet port on each module. Slots 5 and 6 are reserved for the supervisor modules. • Seven slots for optional modules that can include up to seven switching modules or six IPS modules. • Two power supplies located in the front of the chassis. The power supplies are redundant by default and can be configured to be combined if desired. • One hot-swappable fan module with redundant fans. Figure 1-3 Cisco MDS 9509 Chassis 1 2 3 4 5 6 78 1 Switching or services modules in slots 1-4 2 Supervisor module in slot 5 3 Redundant supervisor module in slot 6 4 Switching or services modules in slots 7-9 5 Fan module 6 Power supply 1 7 ESD socket 8 Power supply 2 (redundant) Cisco MDS 9500 Series Hardware Installation Guide 1-6 91692 OL-17467-02

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288

Send documentation comments to [email protected].
1-6
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1
Product Overview
Chassis
Cisco MDS 9509 Director
The Cisco MDS 9509 Director has a 9-slot chassis as shown in
Figure 1-3
, and it supports the following:
Redundant Supervisor-2 modules with associated internal crossbar modules.
Up to two Supervisor-1 modules that provide a switching fabric, plus a console port, COM1 port,
and a MGMT 10/100 Ethernet port on each module. Slots 5 and 6 are reserved for the supervisor
modules.
Seven slots for optional modules that can include up to seven switching modules or six IPS modules.
Two power supplies located in the front of the chassis. The power supplies are redundant by default
and can be configured to be combined if desired.
One hot-swappable fan module with redundant fans.
Figure 1-3
Cisco MDS 9509 Chassis
1
Switching or services modules in
slots 1–4
5
Fan module
2
Supervisor module in slot 5
6
Power supply 1
3
Redundant supervisor module in
slot 6
7
ESD socket
4
Switching or services modules in
slots 7–9
8
Power supply 2 (redundant)
91692
1
4
5
6
8
7
2
3