HP Cisco MDS 9020 Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 33
Status, Description, Table 1-2, LEDs for the Cisco MDS 9513 Director Power Supplies
View all HP Cisco MDS 9020 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Chapter 1 Product Overview Power Supplies Send documentation comments to [email protected]. Table 1-2 describes the LEDs for the Cisco MDS 9513 Director power supplies. Table 1-2 LEDs for the Cisco MDS 9513 Director Power Supplies LED Input 1 OK Status Green Input 2 OK Off Green Off INPUT 1 = 220VAC Green Off INPUT 2 = 220VAC Green Off FAN OK OUTPUT FAIL Green Off Red Off Description AC input at greater than 85 V is good and power supply is functioning normally if two single 110 V or one single 220 V are connected. Power supply is turned off or power is not connected. AC input at greater than 85 V is good and power supply is functioning normally if two single 110 V or one single 220 V are connected. Power supply is turned off or power is not connected. AC input is good at greater than 168 V and power supply should function normally. AC input is 163 V or less or power is not connected. AC input is good at greater than 168 V and power supply should function normally. AC input is 163 V or less or power is not connected. Power supply fans are operating properly. Fan is not operating or power supply is off. Power supply is not in a stable state. If this indication continues after initial power on, check that all connections are secure, including the system fan tray. Normal operation or power supply is turned off. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-11