HP Cisco MDS 9020 Cisco MDS 9500 Series Hardware Installation Guide (OL-17467- - Page 61

Switching Module Features

Page 61 highlights

Chapter 1 Product Overview Switching Modules Send documentation comments to [email protected]. Switching Module Features Each switching module draws its power from the 42 V supplied on the backplane with local DC/DC power converters and regulators. The control processor on the switching module provides power-on, offline, and online diagnostics. The control processor can be used for configuring devices on the switching module and to gather statistical data from each port. The control processor can determine which slot it is plugged into, and it can monitor its DC/DC power source and temperature. The control processor signals the supervisor module and displays an alarm on its front panel when a problem is detected. The front panel on the switching module provides basic status information, such as power-on, self-test running, self-test passed, alarm, and ready. The binary image for the switching module is downloaded from the supervisor module. Prior to the image download, the control processor on the switching module runs from code stored on its local CompactFlash card. Note Routine software downloads are not required. The supervisor module can force a reset on the switching module and controls whether power is applied to the switching module. If a single component or a set of components on the switching module fails, this does not disable other switching modules if that is the only failure in the system. Each switching module has a hardware watchdog timer for detecting most component failures. This watchdog resets the card if is not serviced periodically. OL-17467-02 Cisco MDS 9500 Series Hardware Installation Guide 1-39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288

Send documentation comments to [email protected].
1-39
Cisco MDS 9500 Series Hardware Installation Guide
OL-17467-02
Chapter 1
Product Overview
Switching Modules
Switching Module Features
Each switching module draws its power from the 42 V supplied on the backplane with local DC/DC
power converters and regulators.
The control processor on the switching module provides power-on, offline, and online diagnostics. The
control processor can be used for configuring devices on the switching module and to gather statistical
data from each port.
The control processor can determine which slot it is plugged into, and it can monitor its DC/DC power
source and temperature. The control processor signals the supervisor module and displays an alarm on
its front panel when a problem is detected.
The front panel on the switching module provides basic status information, such as power-on, self-test
running, self-test passed, alarm, and ready.
The binary image for the switching module is downloaded from the supervisor module. Prior to the
image download, the control processor on the switching module runs from code stored on its local
CompactFlash card.
Note
Routine software downloads are not required.
The supervisor module can force a reset on the switching module and controls whether power is applied
to the switching module.
If a single component or a set of components on the switching module fails, this does not disable other
switching modules if that is the only failure in the system.
Each switching module has a hardware watchdog timer for detecting most component failures. This
watchdog resets the card if is not serviced periodically.