HP Integrity Superdome SX1000 Windows Integrity Management Agents Reference - Page 103

Foundation Agent Events, Recommended Action: Make sure to have HP supported DIMMs installed. SNMP

Page 103 highlights

Event ID Event Severity Event Description 12557 Warning HP unsupported DIMM(s) has been detected on this partition. Probable Cause: HP PFM service has detected one or more HP unsupported DIMMs on this partition. Recommended Action: Make sure to have HP supported DIMMs installed. SNMP Trap: hpevtUnSupprtDimmInPartition - 12557 in HPIFPTRAP.MIB. 12560 Error OS run-time critical shutdown occurred. Probable Cause: The OS has caused the system to shut down. Recommended Action: Look at OS logs and crash data to determine why the system shut down. SNMP Trap: hpevtRuntimeCritShtDwn 12560 in HPIFPTRAP.MIB. 12586 Error The amount of power expected to be drawn by the currently operating hardware is greater than the rating of the currently operating Bulk Power Supplies (BPS). Probable Cause: A bulk power supply has failed or was removed when the system had the minimal number of required bulk power supplies. Recommended Action: Replace the failed or removed bulk power supply. SNMP Trap: hpevtPwrExptGreatrPwrBulk - 12586 in HPIFPTRAP.MIB. 12589 Error Bulk power supply (BPS) redundancy has been lost on one or more row(s) of power supplies in the complex. The further loss of a single BPS or an AC grid will most likely result in the shutdown of partitions. Probable Cause: An AC source has been lost. Recommended Action: Verify that the chassis is connected to working power grid(s). SNMP Trap: hpevtBulkPwrReduncLost - 12589 in HPIFPTRAP.MIB. 12591 Error AC redundancy has been lost on one or more power supplies in the complex. The further loss of a single Bulk Power Supply (BPS) or the other AC grid will most likely result in the shutdown of partitions. Probable Cause: A configuration change has been made to the system that changes the amount of power used. Recommended Action: Relook at the configuration changes. SNMP Trap: hpevtACReduncLost 12591 in HPIFPTRAP.MIB. 12593 Error The fans that cool a region of the system are not redundant. If an additional fan fails or is removed from this cooling domain, the partitions on this system will be shut down to prevent damage. Probable Cause: One or more fans in the cooling domain have been removed or are not functioning properly. Recommended Action: Removed failed fan (if any) and insert working fan. SNMP Trap: hpevtFanCoolNotRedunc 12593 in HPIFPTRAP.MIB. 12595 Error An insufficient number of fans are working in a cooling domain to permit system operation. Running partitions will be shut down immediately to prevent damage due to excessive heat. Probable Cause: More than one fan in a cooling domain have been removed or are not functioning properly. Recommended Action: Remove failed fan(s), if any, and insert working fans. SNMP Trap: hpevtFanInsufficientInCoolDomain - 12595 in HPIFPTRAP.MIB. 12627 Warning Operating system is not using all available processors for the current system Probable Cause: Operating system license doesn't allow all processors to be used, or some processors are disabled / deconfigured. Recommended Action: Verify the correct operating system license to be used; Verify if all processors are enabled. SNMP Trap: hpevtOSNotUseAllProcs - 12627 in HPIFPTRAP.MIB. Foundation Agent Events Event ID Event Severity Event Description 256 Warning The Foundation Agents service detected an error. The insertion string is: %1. The data contains the error code. 257 Warning The Foundation Agents service could not allocate memory. The data contains the error code. 258 Warning The Foundation Agents service could not register with the Service Control Manager. The data contains the error code. 259 Warning The Foundation Agents service could not set the service status with the Service Control Manager. The data contains the error code. Foundation Agent Events 103

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

Event Description
Event Severity
Event ID
HP unsupported DIMM(s) has been detected on this partition. Probable Cause: HP
PFM service has detected one or more HP unsupported DIMMs on this partition.
Recommended Action: Make sure to have HP supported DIMMs installed. SNMP
Trap: hpevtUnSupprtDimmInPartition - 12557 in HPIFPTRAP.MIB.
Warning
12557
OS run-time critical shutdown occurred. Probable Cause: The OS has caused the
system to shut down. Recommended Action: Look at OS logs and crash data to
determine why the system shut down. SNMP Trap: hpevtRuntimeCritShtDwn -
12560 in HPIFPTRAP.MIB.
Error
12560
The amount of power expected to be drawn by the currently operating hardware is
greater than the rating of the currently operating Bulk Power Supplies (BPS). Probable
Cause: A bulk power supply has failed or was removed when the system had the
minimal number of required bulk power supplies. Recommended Action: Replace
the failed or removed bulk power supply. SNMP Trap: hpevtPwrExptGreatrPwrBulk
- 12586 in HPIFPTRAP.MIB.
Error
12586
Bulk power supply (BPS) redundancy has been lost on one or more row(s) of power
supplies in the complex. The further loss of a single BPS or an AC grid will most
likely result in the shutdown of partitions. Probable Cause: An AC source has been
lost. Recommended Action: Verify that the chassis is connected to working power
grid(s). SNMP Trap: hpevtBulkPwrReduncLost - 12589 in HPIFPTRAP.MIB.
Error
12589
AC redundancy has been lost on one or more power supplies in the complex. The
further loss of a single Bulk Power Supply (BPS) or the other AC grid will most likely
result in the shutdown of partitions. Probable Cause: A configuration change has
been made to the system that changes the amount of power used. Recommended
Action: Relook at the configuration changes. SNMP Trap: hpevtACReduncLost -
12591 in HPIFPTRAP.MIB.
Error
12591
The fans that cool a region of the system are not redundant. If an additional fan fails
or is removed from this cooling domain, the partitions on this system will be shut
down to prevent damage. Probable Cause: One or more fans in the cooling domain
have been removed or are not functioning properly. Recommended Action: Removed
failed fan (if any) and insert working fan. SNMP Trap: hpevtFanCoolNotRedunc -
12593 in HPIFPTRAP.MIB.
Error
12593
An insufficient number of fans are working in a cooling domain to permit system
operation. Running partitions will be shut down immediately to prevent damage
due to excessive heat. Probable Cause: More than one fan in a cooling domain have
been removed or are not functioning properly. Recommended Action: Remove failed
fan(s), if any, and insert working fans. SNMP Trap:
hpevtFanInsufficientInCoolDomain - 12595 in HPIFPTRAP.MIB.
Error
12595
Operating system is not using all available processors for the current system Probable
Cause: Operating system license doesn't allow all processors to be used, or some
processors are disabled / deconfigured. Recommended Action: Verify the correct
operating system license to be used; Verify if all processors are enabled. SNMP Trap:
hpevtOSNotUseAllProcs - 12627 in HPIFPTRAP.MIB.
Warning
12627
Foundation Agent Events
Event Description
Event Severity
Event ID
The Foundation Agents service detected an error. The insertion string is: %1. The
data contains the error code.
Warning
256
The Foundation Agents service could not allocate memory. The data contains the
error code.
Warning
257
The Foundation Agents service could not register with the Service Control Manager.
The data contains the error code.
Warning
258
The Foundation Agents service could not set the service status with the Service
Control Manager. The data contains the error code.
Warning
259
Foundation Agent Events