HP Integrity Superdome SX1000 Windows Integrity Management Agents Reference - Page 76
In Hpifptrap.mib.
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
Event ID Event Severity Event Description 10402 Warning Arches Fabric Traversability code unexpectedly found the local cell link not connected. Data field: linkState (0 = connected, 1 = link pending, 2 = not connected, -1 = error) Probable Cause: A previously healthy link was found to have fatal errors. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtArchFabFndLocCelLnkNotConn - 10402 in HPIFPTRAP.MIB. 10403 Warning Error reading the ROUTEx CSR on the XBC. Data field: route index | (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtXbcErrRdRoutCsr - 10403 in HPIFPTRAP.MIB. 10404 Warning Unable to read the ALB ALREC_ALB_ID CSR for an XBC port. Data field: (xbcNum 32) | (portNum 48). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtXbcUnablRdAlrecAlbIdCsr - 10404 in HPIFPTRAP.MIB. 10405 Warning An XBC port has an unexpected neighbor chip type. Data field: expected neighbor chip type | (actual neighbor chip type 32). Probable Cause: System firmware found a discrepancy in the expected system topology. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtXbcPrtHasUnxpctNgbrChptype - 10405 in HPIFPTRAP.MIB. 10406 Warning A Cell-Cell link has an unexpected neighbor chip type. Data field: expected neighbor chip type | (actual neighbor chip type 32). Probable Cause: System firmware has found a discrepancy in the expected system topology. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtCelToCelLnkHasUnxpctNgbrChpType 10406 in HPIFPTRAP.MIB. 10407 Warning The cell/port pair does not exist in the Arches Fabric expected graph data. Data field: CC port | (cellNum 32). Probable Cause: System firmware was unable to read a fabric hardware register. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtCelPrtPairNotExstGrphDat - 10407 in HPIFPTRAP.MIB. 10408 Warning A Cell-Cell link is connected to an unexpected neighbor port. Data field: expected neighbor port | (actual neighbor port 32). Probable Cause: System firmware found a discrepancy in the expected system topology. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtCelToCelLnkConnUnxpctNgbrPrt - 10408 in HPIFPTRAP.MIB. 10409 Warning A Cell-Cell link is connected to an unexpected cell. Data field: expected neighbor ID | (actual neighbor ID 16) | (target cell 32) | (local cell 48). Probable Cause: System firmware found a discrepancy in the expected system topology. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtCelToCelLnkConnUnxpctCel - 10409 in HPIFPTRAP.MIB. 10412 Warning An EFI driver failed to load. Probable Cause: A reflashable EFI Driver has failed a checksum test. Recommended Action: Reflash the system firmware to correct this error. SNMP Trap: hpevtEFIDrvrFailLoad - 10412 in HPIFPTRAP.MIB. 10413 Warning VM_FindAllRoutes returned an unexpected error during Non-Coherent table setup. Data field: (return value) | (source cell 32) | (target cell 48). Probable Cause: Internal firmware error or data corruption. Recommended Action: Capture IPMI event logs, look for additional errors. Contact your HP Support Representative to analyze the fabric SNMP Trap: hpevtVmRetErrNonCohTbl - 10413 in HPIFPTRAP.MIB. 76 Management Agents Event Tables