HIOPB_VOLT_MRGN_FAIL entries as well as SYS_BKP_VOLT_MRGN_FAIL, it is

Page 44 highlights

Event ID Event Severity Event Description 7856 Error Invalid checksum from EEPROM Probable Cause: Problem with I2C bus. Recommended Action: If every entity with a FRUID logs an error, the problem is probably with the CLU portion of the Utilities Board. Replace the Utilities Board following the Utilities Board Remove and Replace Procedures. If there are a few entities reporting checksum errors, but several have reported in properly, chances are one device is causing the problem with the I2C bus. This will take a more concerted effort to find and correct that problem. Probably wish to take the bus to a minimum configuration and test, add, test until the failure is verified. SNMP Trap: hpevtEepromInvalidCksm - 7856 in HPIFPTRAP.MIB. 7858 Warning System Backplane Power Board Fault Probable Cause: A DC-DC converter on the named power board failed. Recommended Action: Contact HP Support personnel to troubleshoot the problem Caution: The 1.8 volt converters are N+1. The 3.3 volt converters are N+2.If there is a situation where a 1.8 fails at the same time as a 3.3 on a different power board, replace the failed 1.8 board first. SNMP Trap: hpevtHbpbBoardPowerFault - 7858 in HPIFPTRAP.MIB. 7863 Warning Read of EEPROM failed Probable Cause: The I2C controller on the Utilities Board (CLU section) is bad. This will be shown by many I2C failure codes in the Error Log. These codes should identify entities on both the System Backplane and the Master IO Backplane. Recommended Action: Contact HP Support personnel to troubleshoot the problem. SNMP Trap: hpevtHiobEepromRdFail - 7863 in HPIFPTRAP.MIB. 7864 Warning Read of EEPROM failed Probable Cause: The cable from the Utilities Backplane to the Master IO Backplane is bad, or is not properly connected. Recommended Action: Check and reseat the Master IO Backplane Utilities cable. If no help, contact HP Support personnel to troubleshoot the problem. SNMP Trap: hpevtHiopbEepromRdFail - 7864 in HPIFPTRAP.MIB. 7865 Warning Read of LPM Fault failed Probable Cause: The cable from the Utilities Backplane to the Master IO Backplane is bad, or is not properly connected. Recommended Action: Check and reseat the Master IO Backplane Utilities cable. If no help, contact HP Support personnel to troubleshoot the problem. SNMP Trap: hpevtHiopbLpmFltRdFail - 7865 in HPIFPTRAP.MIB. 7866 Error IO Power Board Over temperature Probable Cause: The ambient air is too warm. Recommended Action: Check the Error Log for other Overtemp Warnings to confirm the environmental problem. SNMP Trap: hpevtHiopbOvertemp - 7866 in HPIFPTRAP.MIB. 7867 Error IO Power Board Fault Probable Cause: The named power brick on the named IO Chassis has failed. Recommended Action: Contact HP Support personnel to troubleshoot the problem. SNMP Trap: hpevtHiopbPowerFault - 7867 in HPIFPTRAP.MIB. 7871 Warning Voltage Margin on IO Power Board failed Probable Cause: The IO Power Board LPM is not communicating with the CLU. Recommended Action: Some troubleshooting will be involved here. Is it the IO Power Board LPM, or the CLU. You'll have to check the Error Log for other entries related to either CLU communications problems or the IO Power Board LPM. If there are messages about other HIOPB_VOLT_MRGN_FAIL entries as well as SYS_BKP_VOLT_MRGN_FAIL, it is pointing to the CLU. SNMP Trap: hpevtHiopbVoltMrgnFail - 7871 in HPIFPTRAP.MIB. 7873 Warning Failure to read data from a SBCH FRUID EEPROM Probable Cause: The CLU cannot read the data contained in the EEPROM on the SBCH board in the same cabinet. Recommended Action: Contact HP Support personnel to troubleshoot the problem. If this is the only READ failure in this timeframe, replace the SBCH board following the SBCH Board Remove + Replace Procedures as soon as possible. If there are other READ failures in this same cabinet, replace the Utilities Board following the Utilities Board Remove and Replace Procedures. SNMP Trap: hpevtSbchEepromRdFail - 7873 in HPIFPTRAP.MIB. 44 Management Agents Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

Event Description
Event Severity
Event ID
Invalid checksum from EEPROM Probable Cause: Problem with I2C bus.
Recommended Action: If every entity with a FRUID logs an error, the problem is
probably with the CLU portion of the Utilities Board. Replace the Utilities Board
following the Utilities Board Remove and Replace Procedures. If there are a few
entities reporting checksum errors, but several have reported in properly, chances
are one device is causing the problem with the I2C bus. This will take a more concerted
effort to find and correct that problem. Probably wish to take the bus to a minimum
configuration and test, add, test until the failure is verified. SNMP Trap:
hpevtEepromInvalidCksm - 7856 in HPIFPTRAP.MIB.
Error
7856
System Backplane Power Board Fault Probable Cause: A DC-DC converter on the
named power board failed. Recommended Action: Contact HP Support personnel
to troubleshoot the problem Caution: The 1.8 volt converters are N+1. The 3.3 volt
converters are N+2.If there is a situation where a 1.8 fails at the same time as a 3.3 on
a different power board, replace the failed 1.8 board first. SNMP Trap:
hpevtHbpbBoardPowerFault - 7858 in HPIFPTRAP.MIB.
Warning
7858
Read of EEPROM failed Probable Cause: The I2C controller on the Utilities Board
(CLU section) is bad. This will be shown by many I2C failure codes in the Error Log.
These codes should identify entities on both the System Backplane and the Master
IO Backplane. Recommended Action: Contact HP Support personnel to troubleshoot
the problem. SNMP Trap: hpevtHiobEepromRdFail - 7863 in HPIFPTRAP.MIB.
Warning
7863
Read of EEPROM failed Probable Cause: The cable from the Utilities Backplane to
the Master IO Backplane is bad, or is not properly connected. Recommended Action:
Check and reseat the Master IO Backplane Utilities cable. If no help, contact HP
Support personnel to troubleshoot the problem. SNMP Trap:
hpevtHiopbEepromRdFail - 7864 in HPIFPTRAP.MIB.
Warning
7864
Read of LPM Fault failed Probable Cause: The cable from the Utilities Backplane to
the Master IO Backplane is bad, or is not properly connected. Recommended Action:
Check and reseat the Master IO Backplane Utilities cable. If no help, contact HP
Support personnel to troubleshoot the problem. SNMP Trap:
hpevtHiopbLpmFltRdFail - 7865 in HPIFPTRAP.MIB.
Warning
7865
IO Power Board Over temperature Probable Cause: The ambient air is too warm.
Recommended Action: Check the Error Log for other Overtemp Warnings to confirm
the environmental problem. SNMP Trap: hpevtHiopbOvertemp - 7866 in
HPIFPTRAP.MIB.
Error
7866
IO Power Board Fault Probable Cause: The named power brick on the named IO
Chassis has failed. Recommended Action: Contact HP Support personnel to
troubleshoot the problem. SNMP Trap: hpevtHiopbPowerFault - 7867 in
HPIFPTRAP.MIB.
Error
7867
Voltage Margin on IO Power Board failed Probable Cause: The IO Power Board LPM
is not communicating with the CLU. Recommended Action: Some troubleshooting
will be involved here. Is it the IO Power Board LPM, or the CLU. You'll have to check
the Error Log for other entries related to either CLU communications problems or
the IO Power Board LPM. If there are messages about other
HIOPB_VOLT_MRGN_FAIL entries as well as SYS_BKP_VOLT_MRGN_FAIL, it is
pointing to the CLU. SNMP Trap: hpevtHiopbVoltMrgnFail - 7871 in
HPIFPTRAP.MIB.
Warning
7871
Failure to read data from a SBCH FRUID EEPROM Probable Cause: The CLU cannot
read the data contained in the EEPROM on the SBCH board in the same cabinet.
Recommended Action: Contact HP Support personnel to troubleshoot the problem.
If this is the only READ failure in this timeframe, replace the SBCH board following
the SBCH Board Remove + Replace Procedures as soon as possible. If there are other
READ failures in this same cabinet, replace the Utilities Board following the Utilities
Board Remove and Replace Procedures. SNMP Trap: hpevtSbchEepromRdFail - 7873
in HPIFPTRAP.MIB.
Warning
7873
44