HP Integrity Superdome SX1000 Windows Integrity Management Agents Reference - Page 22

OS INIT address not registered Probable Cause: The OS has not registered an OS_INIT

Page 22 highlights

Event ID Event Severity Event Description 5260 Warning OS INIT address not registered Probable Cause: The OS has not registered an OS_INIT vector. Recommended Action: No action is required. The OS has failed to register the vector or has chosen not to. SNMP Trap: hpevtOsInitNotRegistered - 5260 in HPIFPTRAP.MIB. 5263 Warning OS MCA address not registered Probable Cause: The OS has not registered an OS_MCA vector. Recommended Action: None, the OS has failed to register the vector or has chosen not to. SNMP Trap: hpevtOsMcaNotRegistered - 5263 in HPIFPTRAP.MIB. 5264 Warning OS MCA did not correct the Machine Check Probable Cause: Uncorrected Machine Check. Recommended Action: Analyze cause of Machine Check using diagnostic and EFI tools. SNMP Trap: hpevtOsMcaUncorrectedMc - 5264 in HPIFPTRAP.MIB. 5266 Error Found bad miscellaneous register Probable Cause: A PDH register has failed. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. SNMP Trap: hpevtPdhMiscRegFail - 5266 in HPIFPTRAP.MIB. 5268 Warning SAL_CHECK failed for an unknown reason Probable Cause: The handler for SAL_CHECK has failed for an unknown reason. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. SNMP Trap: hpevtSalCheckUnknownFail - 5268 in HPIFPTRAP.MIB. 5270 Warning SAL_INIT failed for an unknown reason Probable Cause: The handler for SAL_INIT has failed for an unknown reason. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. SNMP Trap: hpevtSalInitUnknownFail - 5270 in HPIFPTRAP.MIB. 5278 Warning Unspecified memory interleave error Probable Cause: FW encountered a fatal interleaving error. Recommended Action: Update SFW Recommended Action: Contact HP support to troubleshoot the problem SNMP Trap: hpevtUndefinedSmcInterleaveErr - 5278 in HPIFPTRAP.MIB. 5279 Error Unexpected return to SAL_CHECK Probable Cause: Unexpected return to SAL_CHECK. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. SNMP Trap: hpevtUnexpectedRetToSalCheck - 5279 in HPIFPTRAP.MIB. 5280 Error Unexpected return to SAL_INIT Probable Cause: SAL_INIT has been unexpectedly returned to. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. SNMP Trap: hpevtUnexpectedRetToSalInit 5280 in HPIFPTRAP.MIB. 5335 Warning Firmware is adding a DEGRADED cpu node to the device tree. Probable Cause: A CPU that is not fully functional is installed in the cell board. Recommended Action: Replace cpu indicated in data field of event. SNMP Trap: hpevtFwInstalledCpuDegraded - 5335 in HPIFPTRAP.MIB. 5354 Error PD rendezvous will fail do to a Firmware Tree error Probable Cause: Decode the ASCII string in the data field to determine what resource is missing. Examine earlier chassis codes to determine why that resource is unavailable. SNMP Trap: hpevtPdRendezTreeError - 5354 in HPIFPTRAP.MIB. 5359 Error The current cell is not configured as part of the expected set Probable Cause: A bad complex profile exists. Correct and redistribute. SNMP Trap: hpevtPdCellConfigError - 5359 in HPIFPTRAP.MIB. 5360 Error A remote CSR could not be read Probable Cause: Either a hardware connection problem exists, or fabric was unable to be routed. Verify hardware and reset. SNMP Trap: hpevtPdRemoteCsrReadError - 5360 in HPIFPTRAP.MIB. 5361 Error The current cell is too late to rendezvous with other cells Probable Cause: This cell took to long completing previous steps to rendezvous. A bad complex profile could also cause this problem. SNMP Trap: hpevtPdCellLateForRendez - 5361 in HPIFPTRAP.MIB. 22 Management Agents Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

Event Description
Event Severity
Event ID
OS INIT address not registered Probable Cause: The OS has not registered an OS_INIT
vector. Recommended Action: No action is required. The OS has failed to register
the vector or has chosen not to. SNMP Trap: hpevtOsInitNotRegistered - 5260 in
HPIFPTRAP.MIB.
Warning
5260
OS MCA address not registered Probable Cause: The OS has not registered an
OS_MCA vector. Recommended Action: None, the OS has failed to register the vector
or has chosen not to. SNMP Trap: hpevtOsMcaNotRegistered - 5263 in
HPIFPTRAP.MIB.
Warning
5263
OS MCA did not correct the Machine Check Probable Cause: Uncorrected Machine
Check. Recommended Action: Analyze cause of Machine Check using diagnostic
and EFI tools. SNMP Trap: hpevtOsMcaUncorrectedMc - 5264 in HPIFPTRAP.MIB.
Warning
5264
Found bad miscellaneous register Probable Cause: A PDH register has failed.
Recommended Action: Reboot if necessary, if problem persists contact your HP
representative for support. SNMP Trap: hpevtPdhMiscRegFail - 5266 in
HPIFPTRAP.MIB.
Error
5266
SAL_CHECK failed for an unknown reason Probable Cause: The handler for
SAL_CHECK has failed for an unknown reason. Recommended Action: Reboot if
necessary, if problem persists contact your HP representative for support. SNMP
Trap: hpevtSalCheckUnknownFail - 5268 in HPIFPTRAP.MIB.
Warning
5268
SAL_INIT failed for an unknown reason Probable Cause: The handler for SAL_INIT
has failed for an unknown reason. Recommended Action: Reboot if necessary, if
problem persists contact your HP representative for support. SNMP Trap:
hpevtSalInitUnknownFail - 5270 in HPIFPTRAP.MIB.
Warning
5270
Unspecified memory interleave error Probable Cause: FW encountered a fatal
interleaving error. Recommended Action: Update SFW Recommended Action: Contact
HP support to troubleshoot the problem SNMP Trap:
hpevtUndefinedSmcInterleaveErr - 5278 in HPIFPTRAP.MIB.
Warning
5278
Unexpected return to SAL_CHECK Probable Cause: Unexpected return to
SAL_CHECK. Recommended Action: Reboot if necessary, if problem persists contact
your HP representative for support. SNMP Trap: hpevtUnexpectedRetToSalCheck
- 5279 in HPIFPTRAP.MIB.
Error
5279
Unexpected return to SAL_INIT Probable Cause: SAL_INIT has been unexpectedly
returned to. Recommended Action: Reboot if necessary, if problem persists contact
your HP representative for support. SNMP Trap: hpevtUnexpectedRetToSalInit -
5280 in HPIFPTRAP.MIB.
Error
5280
Firmware is adding a DEGRADED cpu node to the device tree. Probable Cause: A
CPU that is not fully functional is installed in the cell board. Recommended Action:
Replace cpu indicated in data field of event. SNMP Trap:
hpevtFwInstalledCpuDegraded - 5335 in HPIFPTRAP.MIB.
Warning
5335
PD rendezvous will fail do to a Firmware Tree error Probable Cause: Decode the
ASCII string in the data field to determine what resource is missing. Examine earlier
chassis codes to determine why that resource is unavailable. SNMP Trap:
hpevtPdRendezTreeError - 5354 in HPIFPTRAP.MIB.
Error
5354
The current cell is not configured as part of the expected set Probable Cause: A bad
complex profile exists. Correct and redistribute. SNMP Trap: hpevtPdCellConfigError
- 5359 in HPIFPTRAP.MIB.
Error
5359
A remote CSR could not be read Probable Cause: Either a hardware connection
problem exists, or fabric was unable to be routed. Verify hardware and reset. SNMP
Trap: hpevtPdRemoteCsrReadError - 5360 in HPIFPTRAP.MIB.
Error
5360
The current cell is too late to rendezvous with other cells Probable Cause: This cell
took to long completing previous steps to rendezvous. A bad complex profile could
also cause this problem. SNMP Trap: hpevtPdCellLateForRendez - 5361 in
HPIFPTRAP.MIB.
Error
5361
22
Management Agents Event Tables