HP Integrity Superdome SX1000 Windows Integrity Management Agents Reference - Page 71
Event Description, Event Severity, Event ID
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
Event ID Event Severity Event Description 9867 Warning CPU deconfigured during FSB interface initialization Probable Cause: internal error. Recommended Action: the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. SNMP Trap: hpevtDcnfgFsbInit - 9867 in HPIFPTRAP.MIB. 9868 Warning CPU deconfigured due to error obtaining parameters from PAL Probable Cause: internal error. Recommended Action: the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. SNMP Trap: hpevtDcnfgCpuParams - 9868 in HPIFPTRAP.MIB. 9869 Warning CPU deconfigured due to failure retrieving icache parameters from PAL Probable Cause: internal error. Recommended Action: during system boot the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. SNMP Trap: hpevtDcnfgCpuIcache - 9869 in HPIFPTRAP.MIB. 9870 Warning CPU deconfigured during initialization process Probable Cause: internal error. Recommended Action: during system boot the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. SNMP Trap: hpevtDcnfgCpuDcache - 9870 in HPIFPTRAP.MIB. 9871 Warning CPU deconfigured during dcache init Probable Cause: internal error. Recommended Action: the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. SNMP Trap: hpevtDcnfgCpuCacheState - 9871 in HPIFPTRAP.MIB. 9872 Warning CPU deconfigured due to internal error Probable Cause: internal error. Recommended Action: the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. SNMP Trap: hpevtDcnfgCpuCacheMonitor - 9872 in HPIFPTRAP.MIB. 9873 Warning CPU deconfigured due to machine check Probable Cause: internal error. Recommended Action: the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. SNMP Trap: hpevtDcnfgCpuMca - 9873 in HPIFPTRAP.MIB. 9874 Warning CPU deconfigured due to error while disabling machine check Probable Cause: internal error. Recommended Action: the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. SNMP Trap: hpevtDcnfgCpuDisableMca - 9874 in HPIFPTRAP.MIB. 9875 Warning CPU deconfigured due to failure in late self tests Probable Cause: internal error. Recommended Action: the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. SNMP Trap: hpevtDcnfgCpuSelfTest - 9875 in HPIFPTRAP.MIB. 9876 Warning CPU deconfigured while enabling L2 shared cache Probable Cause: internal error. Recommended Action: the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. SNMP Trap: hpevtDcnfgCpuL2Cache - 9876 in HPIFPTRAP.MIB. 9877 Warning CPU deconfigured while retrieving default values from PAL Probable Cause: internal error. Recommended Action: the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. SNMP Trap: hpevtDcnfgCpuDefValue - 9877 in HPIFPTRAP.MIB. 9878 Warning CPU deconfigured getting an address for a CPU internal register within a buffer from the CPU abstraction layer Probable Cause: internal error. Recommended Action: the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. SNMP Trap: hpevtDcnfgCpuInReg - 9878 in HPIFPTRAP.MIB. 9879 Warning CPU deconfigured while getting an address for a CPU internal register within a buffer from the CPU abstraction layer Probable Cause: internal error. Recommended Action: the CPU will be deconfigured. If the error persists after a powercycle, contact HP Support. SNMP Trap: hpevtDcnfgCpuProgReg - 9879 in HPIFPTRAP.MIB. 9896 Error Not enough error free memory to run late sefltests Probable Cause: Due to excessive memory subsystem or DIMM errors, the late selftests could not be run. DIMMs or memory extenders have caused excessive errors and will need to be replaced. Consult the memory test events regarding memory errors or view the Page Deallocation Table from BCH. SNMP Trap: hpevtNoMemSelfTest - 9896 in HPIFPTRAP.MIB. Platform Agent Events 71