The Stable Complex Profile Sequence Id is invalid Probable Cause: Push out a new
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Event ID Event Severity Event Description 5569 Error This indicates the failure in updating the GNI info of the cell with CLM. Probable Cause: The partition level memory will fail at this point. SNMP Trap: hpevtPdMemUpdateCellGniFailed - 5569 in HPIFPTRAP.MIB. 5570 Error This indicates the failure in adjusting the mem info with Minimum ZI req. Probable Cause: This will cause the partition level memory to exit cell interleaving. SNMP Trap: hpevtPdMemAdjustMinZiFailed - 5570 in HPIFPTRAP.MIB. 5572 Error Complex Profile A has a checksum error Probable Cause: Reconfigure the system get a new complex profile distributed and reset. SNMP Trap: hpevtStableProfileXsumError - 5572 in HPIFPTRAP.MIB. 5573 Warning A Checksum error was encountered in the dynamic profile Probable Cause: Push out a new complex profile and reset. SNMP Trap: hpevtDynamicProfileXsumError - 5573 in HPIFPTRAP.MIB. 5574 Warning A checksum error occurred on the Partition Profile. Probable Cause: Push out a new complex profile and reboot. SNMP Trap: hpevtPartitionProfileXsumError - 5574 in HPIFPTRAP.MIB. 5575 Error The Stable Complex Profile Sequence Id is invalid Probable Cause: Push out a new complex profile and reset the system. The cell will be waiting for reconfiguration. SNMP Trap: hpevtStableProfileSeqidInvalid - 5575 in HPIFPTRAP.MIB. 5577 Warning The Dynamic Complex Profile Sequence ID is invalid Probable Cause: Push out a new complex profile. SNMP Trap: hpevtDynamicProfileSeqidInvalid - 5577 in HPIFPTRAP.MIB. 5578 Error The Partition Profile Sequence ID is invalid Probable Cause: Push out a new complex profile and reset. The cell will be waiting for reconfiguration. SNMP Trap: hpevtPartitionProfileSeqidInvalid - 5578 in HPIFPTRAP.MIB. 5579 Error Internal Firmware Programming Error from the EFI portion of the firmware Probable Cause: Report the IPF to the firmware team. Reset the system. This cannot be worked around in the field. SNMP Trap: hpevtEfiFwError - 5579 in HPIFPTRAP.MIB. 5580 Error The PD numbers in Group A and Group C of the complex profile are inconsistent. Probable Cause: Push out consistent Complex profiles and reset the system. The cell will be waiting for reconfiguration. SNMP Trap: hpevtCmplxProfilePdNumMismatch - 5580 in HPIFPTRAP.MIB. 5581 Error The PD number specified in the complex profile is out of range. Probable Cause: Reconfigure the partition number, push out a new profile and reset. SNMP Trap: hpevtCmplxProfilePdNumInvalid - 5581 in HPIFPTRAP.MIB. 5583 Warning Could not obtain the crossbar port semaphore Probable Cause: No action required SNMP Trap: hpevtXbcPortSm4Error - 5583 in HPIFPTRAP.MIB. 5584 Warning Could not release the crossbar port semaphore. Probable Cause: No action required. SNMP Trap: hpevtXbcPortSm4NotReleased - 5584 in HPIFPTRAP.MIB. 5594 Error BMC token upload failure Probable Cause: Problem accessing the BMC. Recommended Action: AC power cycle or update BMC and System FW. If problem persists contact your HP representative for support. SNMP Trap: hpevtBootBmcTokenUploadFailure - 5594 in HPIFPTRAP.MIB. 5595 Warning NVM token access failure Probable Cause: NVM Error, or incorrect permissions to read token. Recommended Action: Retry, AC power cycle if necessary, if problem persists contact your HP representative for support. SNMP Trap: hpevtBootNvmTokenAccessFailure - 5595 in HPIFPTRAP.MIB. 5596 Warning BMC token download failure Probable Cause: Problem accessing the BMC. Recommended Action: AC power cycle or update BMC and System FW. If problem persists contact your HP representative for support. SNMP Trap: hpevtBootBmcTokenDownloadError - 5596 in HPIFPTRAP.MIB. 28 Management Agents Event Tables