HP Integrity Superdome SX1000 Windows Integrity Management Agents Reference - Page 53

LBA phase data Recommended Action: Replace the I/O backplane SNMP Trap

Page 53 highlights

Event ID Event Severity Event Description 8715 Warning There was an error initializing the LBA Probable Cause: The LBA component initialization routine failed. Recommended Action: This is an internal system firmware error. Update system firmware or contact a system firmware representative. SNMP Trap: hpevtIodiscLbaInitnodeError - 8715 in HPIFPTRAP.MIB. 8716 Error There was an error querying the LBA width Probable Cause: Error while writing the LBA phase data Recommended Action: Replace the I/O backplane SNMP Trap: hpevtIodiscLbaWidthError - 8716 in HPIFPTRAP.MIB. 8717 Warning There was an error with the LBA phase Probable Cause: Error while writing the LBA phase data Recommended Action: Replace the I/O backplane SNMP Trap: hpevtIodiscLbaPhaseError - 8717 in HPIFPTRAP.MIB. 8718 Warning There was an error clearing the LBA Probable Cause: Unable to clear an error in the LBA Recommended Action: Check other events for the error being generated replace either the PCI card or the I/O backplane SNMP Trap: hpevtIodiscLbaClearError 8718 in HPIFPTRAP.MIB. 8719 Error There was an error with the LBA log Probable Cause: The LBA component could not generate error logs. Recommended Action: This is an internal system firmware error. Update system firmware or contact a system firmware representative. SNMP Trap: hpevtIodiscLbaLogError - 8719 in HPIFPTRAP.MIB. 8720 Error There was an error discovering the LBA Probable Cause: The wrong backplane type was detected Recommended Action: replace I/O backplane SNMP Trap: hpevtIodiscLbaDiscoverError - 8720 in HPIFPTRAP.MIB. 8721 Warning There was an error configuring the LBA Probable Cause: Unable to configure the LBA Recommended Action: replace I/O backplane SNMP Trap: hpevtIodiscLbaConfigError - 8721 in HPIFPTRAP.MIB. 8722 Error There was an error scanning the PCI bus Probable Cause: Could not scan the card in a populated slot. Typically caused by an improperly installed or faulty PCI card. Recommended Action: Reseat or replace the faulty card. SNMP Trap: hpevtIodiscLbaPciscanError - 8722 in HPIFPTRAP.MIB. 8723 Error There was an error configuring PCI space through the LBA Probable Cause: Unable to obtain semaphore Recommended Action: reset Update to latest recipe SNMP Trap: hpevtIodiscLbaPciconfigError - 8723 in HPIFPTRAP.MIB. 8745 Warning The OLA cell failed accessing the complex profile Probable Cause: System firmware was unable to lock either the global or the micro semaphore. Recommended Action: Allow the OLA cell to reboot to BIB, then try the OLA operation again. Or, collect IPMI event logs and contact HP Customer Support for assistance. SNMP Trap: hpevtBootOlaCellErrAccessCmplxProfile - 8745 in HPIFPTRAP.MIB. 8747 Error Firmware was unable to find a suitable block of main memory to relocate ROM Probable Cause: Probably caused by lots of PDT entries, or no main memory present. SNMP Trap: hpevtBootFwRelocMemErr - 8747 in HPIFPTRAP.MIB. 8752 Warning Cell started OLA but is not configured in the complex profile of the partition. Probable Cause: Cell was issued an OLA command without first updating the complex profile to reflect its slot as configured in the partition. Recommended Action: Update the complex profile to include the new cell. SNMP Trap: hpevtBootOlaCellNotConfigInCmplxProfile - 8752 in HPIFPTRAP.MIB. 8756 Error The Options service received an NVRAM allocation error. Probable Cause: Invalidate NVRAM and reset. SNMP Trap: hpevtOptsNvmAllocError - 8756 in HPIFPTRAP.MIB. 8757 Warning failure on OLA cell during attempt to synch its real-time clock Probable Cause: Couldn't communicate with OLA cell. Recommended Action: Collect IPMI events and contact HP Support. SNMP Trap: hpevtBootOlaUpdateRtcFailedOlaCell - 8757 in HPIFPTRAP.MIB. 8758 Warning SAL errlog access timeout Probable Cause: Firmware is taking too long to process requests. SNMP Trap: hpevtSalInfoTimeout - 8758 in HPIFPTRAP.MIB. Platform Agent Events 53

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

Event Description
Event Severity
Event ID
There was an error initializing the LBA Probable Cause: The LBA component
initialization routine failed. Recommended Action: This is an internal system firmware
error. Update system firmware or contact a system firmware representative. SNMP
Trap: hpevtIodiscLbaInitnodeError - 8715 in HPIFPTRAP.MIB.
Warning
8715
There was an error querying the LBA width Probable Cause: Error while writing the
LBA phase data Recommended Action: Replace the I/O backplane SNMP Trap:
hpevtIodiscLbaWidthError - 8716 in HPIFPTRAP.MIB.
Error
8716
There was an error with the LBA phase Probable Cause: Error while writing the LBA
phase data Recommended Action: Replace the I/O backplane SNMP Trap:
hpevtIodiscLbaPhaseError - 8717 in HPIFPTRAP.MIB.
Warning
8717
There was an error clearing the LBA Probable Cause: Unable to clear an error in the
LBA Recommended Action: Check other events for the error being generated replace
either the PCI card or the I/O backplane SNMP Trap: hpevtIodiscLbaClearError -
8718 in HPIFPTRAP.MIB.
Warning
8718
There was an error with the LBA log Probable Cause: The LBA component could not
generate error logs. Recommended Action: This is an internal system firmware error.
Update system firmware or contact a system firmware representative. SNMP Trap:
hpevtIodiscLbaLogError - 8719 in HPIFPTRAP.MIB.
Error
8719
There was an error discovering the LBA Probable Cause: The wrong backplane type
was detected Recommended Action: replace I/O backplane SNMP Trap:
hpevtIodiscLbaDiscoverError - 8720 in HPIFPTRAP.MIB.
Error
8720
There was an error configuring the LBA Probable Cause: Unable to configure the
LBA Recommended Action: replace I/O backplane SNMP Trap:
hpevtIodiscLbaConfigError - 8721 in HPIFPTRAP.MIB.
Warning
8721
There was an error scanning the PCI bus Probable Cause: Could not scan the card
in a populated slot. Typically caused by an improperly installed or faulty PCI card.
Recommended Action: Reseat or replace the faulty card. SNMP Trap:
hpevtIodiscLbaPciscanError - 8722 in HPIFPTRAP.MIB.
Error
8722
There was an error configuring PCI space through the LBA Probable Cause: Unable
to obtain semaphore Recommended Action: reset Update to latest recipe SNMP Trap:
hpevtIodiscLbaPciconfigError - 8723 in HPIFPTRAP.MIB.
Error
8723
The OLA cell failed accessing the complex profile Probable Cause: System firmware
was unable to lock either the global or the micro semaphore. Recommended Action:
Allow the OLA cell to reboot to BIB, then try the OLA operation again. Or, collect
IPMI event logs and contact HP Customer Support for assistance. SNMP Trap:
hpevtBootOlaCellErrAccessCmplxProfile - 8745 in HPIFPTRAP.MIB.
Warning
8745
Firmware was unable to find a suitable block of main memory to relocate ROM
Probable Cause: Probably caused by lots of PDT entries, or no main memory present.
SNMP Trap: hpevtBootFwRelocMemErr - 8747 in HPIFPTRAP.MIB.
Error
8747
Cell started OLA but is not configured in the complex profile of the partition. Probable
Cause: Cell was issued an OLA command without first updating the complex profile
to reflect its slot as configured in the partition. Recommended Action: Update the
complex profile to include the new cell. SNMP Trap:
hpevtBootOlaCellNotConfigInCmplxProfile - 8752 in HPIFPTRAP.MIB.
Warning
8752
The Options service received an NVRAM allocation error. Probable Cause: Invalidate
NVRAM and reset. SNMP Trap: hpevtOptsNvmAllocError - 8756 in HPIFPTRAP.MIB.
Error
8756
failure on OLA cell during attempt to synch its real-time clock Probable Cause:
Couldn't communicate with OLA cell. Recommended Action: Collect IPMI events
and contact HP Support. SNMP Trap: hpevtBootOlaUpdateRtcFailedOlaCell - 8757
in HPIFPTRAP.MIB.
Warning
8757
SAL errlog access timeout Probable Cause: Firmware is taking too long to process
requests. SNMP Trap: hpevtSalInfoTimeout - 8758 in HPIFPTRAP.MIB.
Warning
8758
Platform Agent Events
53