An invalid XBC to XBC port was found. Probable Cause: Loss of Lockstep
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Event ID Event Severity Event Description 5832 Warning Unable to validate blank password during EFI security initialization Probable Cause: BMC failed. Recommended Action: Reset the BMC. Update BMC FW. Contact your HP representative to check the BMC. SNMP Trap: hpevtEfiSecInitVerifyErr - 5832 in HPIFPTRAP.MIB. 5833 Warning Unable to enter Guest mode during EFI security initialization Probable Cause: BMC failure. Recommended Action: Reset the BMC. Update BMC FW. Contact your HP representative to check the BMC. SNMP Trap: hpevtEfiSecInitCloseErr - 5833 in HPIFPTRAP.MIB. 5834 Warning Unable to increase privilege during EFI security initialization Probable Cause: SAL failure. Recommended Action: Reset the system. Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. SNMP Trap: hpevtEfiSecInitOpenErr - 5834 in HPIFPTRAP.MIB. 5836 Warning EFI unable to write privilege level during security initialization Probable Cause: SAL failure. Recommended Action: Reboot the system. Update SFW. If problem persists, contact HP support to troubleshoot the problem. SNMP Trap: hpevtEfiSecInitWriteErr - 5836 in HPIFPTRAP.MIB. 5837 Warning EFI was denied permission to write the privilege level during security init Probable Cause: SAL is not in ADMIN or USER mode. Recommended Action: Reboot the system. Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. SNMP Trap: hpevtEfiSecInitWriteDenied - 5837 in HPIFPTRAP.MIB. 5853 Warning OS dump, error writing image area to disk (E055) Probable Cause: panic path forward progress SNMP Trap: hpevtHp-uxDumpWriteError - 5853 in HPIFPTRAP.MIB. 5896 Error Coherency controller (CC) registers indicate a Deadlock Recovery Reset Probable Cause: Coherency controller (CC) resources are deadlocked and the CC is resetting the cell. Recommended Action: Analyze the Deadlock Recovery logs (like MCA logs) to determine the cause of the failure. SNMP Trap: hpevtErrDeadlockResetDetected - 5896 in HPIFPTRAP.MIB. 6002 Error A memory address parity error has been detected. The physical location can be located in the data field. Probable Cause: Poorly seated memory extender Recommended Action: Reseat memory extender SNMP Trap: hpevtMemParityErr - 6002 in HPIFPTRAP.MIB. 6074 Error A DIMM loading order error has occurred Probable Cause: Incorrect loading of the DIMMs on the cell Recommended Action: Install the DIMMs in the correct order. DIMMs are installed in ranks of DIMMs , starting with DIMM 0A, 0B, etc. Subsequent ranks are loaded in ascending order , i.e., rank 1, 2, 3, 4, 5, 6 and 7. SNMP Trap: hpevtMemDimmLoadOrdErr - 6074 in HPIFPTRAP.MIB. 6146 Warning Refresh Control Error Timeout Probable Cause: At start of memory refresh, timing out waiting for ready bit to be set Recommended Action: Contact HP Support personnel to troubleshoot the problem SNMP Trap: hpevtMemRefreshStartError 6146 in HPIFPTRAP.MIB. 6180 Warning memory extender/baseboard FRU mismatch Probable Cause: Memory extender and baseboard are incompatible Recommended Action: Contact HP support to troubleshoot the problem SNMP Trap: hpevtMemExtBaseboardIncompatible - 6180 in HPIFPTRAP.MIB. 6730 Error Fabric topology mismatch with XBCs in complex Probable Cause: There is a fabric topology mismatch with XBC in complex. Recommended Action: Contact HP Support personnel to analyze the cell, XBC flex cables, system backplane SNMP Trap: hpevtFabricDifferentTopologies - 6730 in HPIFPTRAP.MIB. 6795 Warning An invalid XBC to XBC port was found. Probable Cause: Loss of Lockstep Recommended Action: Reset SNMP Trap: hpevtFabricInvalidXbc2XbcPort - 6795 in HPIFPTRAP.MIB. 38 Management Agents Event Tables