Drive Array Controller Status Change. The Drive Array Controller in %7 has a new

Page 123 highlights

Event ID Event Severity Event Description 1189 Warning Storage System Temperature Status Change. An enclosure attached to port %5 of storage system "%4" has a new temperature status of %7. The enclosure model is "%6". %n(Temperature status values: 1=other, 2=noTemp, 3=ok, 4=degraded, 5=failed) %n [SNMP TRAP: 8023 in CPQSTSYS.MIB] 1190 Warning Storage System Power Supply Status Change. An enclosure attached to port %5 of storage system "%4" has a new power supply status of %7. The enclosure model is "%6". %n(Power supply status values: 1=other, 2=noFltTolPower, 3=ok, 4=degraded, 5=failed, 6=notSupported, 7=noFltTolPower-Bay1Missing, 8=noFltTolPower-Bay2Missing) %n [SNMP TRAP: 8024 in CPQSTSYS.MIB] 1191 Warning SCSI Tape Library Status Change.%nThe tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a new status of %7.%n(Tape library status values: 1=other, 2=ok, 3=degraded, 4=failed, 5=offline)%n [SNMP TRAP: 5018 in CPQSCSI.MIB] 1192 Warning SCSI Tape Drive Status Change.%nThe tape drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.%n(Tape drive status values: 1=other, 2=ok, 3=failed, 5=offline, 6=missingWasOk, 7=missingWasFailed, 8=missingWasOffline)%n [SNMP TRAP: 5019 in CPQSCSI.MIB] 1193 Warning External Tape Drive Status Change. The tape drive at location "%4", has a new status of %7.%n(Tape drive status values: 1=other, 2=ok, 3=degraded, 4=failed, 5=offline, 6=missingWasOk, 7=missingWasOffline)%n [SNMP TRAP: 16023 in CPQFCA.MIB] 1194 External Tape Drive Cleaning Required. The tape drive at location "%4" requires Warning cleaning.%n [SNMP TRAP: 16024 in CPQFCA.MIB] 1195 External Tape Drive Replace Cleaning Tape. The cleaning tape in the tape drive at Warning location "%4" needs to be replaced.%n [SNMP TRAP: 16025 in CPQFCA.MIB] 1196 Warning Storage System Recovery Server Option Status Change. Storage system "%4" has a new RSO status of %5.%n(RSO status values: 1=other, 2=notSupported, 3=notConfigured, 4=disabled, 5=daemonDownDisabled, 6=ok, 7=daemonDownActive, 8=noSecondary, 9=daemonDownNoSecondary, 10=linkDown, 11=daemonDownLinkDown, 12=secondaryRunningAuto, 13=secondaryRunningUser, 14=evTimeoutError) %n [SNMP TRAP: 8025 in CPQSTSYS.MIB] 1197 Warning External Tape Library Status Change. The tape library at location "%4", has a new status of %7.%n(Library status values: 1=other, 2=ok, 3=degraded, 4=failed, 5=offline)%n [SNMP TRAP: 16026 in CPQFCA.MIB] 1198 Warning External Tape Library Door Status Change. The tape library at location "%4", has a new door status of %7.%n(Library door status values: 1=other, 2=notSupported, 3=closed, 4=open)%n [SNMP TRAP: 16027 in CPQFCA.MIB] 1199 Warning Drive Array Controller Status Change. The Drive Array Controller in %7 has a new status of %5.%n(Controller status values: 1=other, 2=ok, 3=generalFailure, 4=cableProblem, 5=poweredOff)%n [SNMP TRAP: 3033 in CPQIDA.MIB] 1200 Warning Drive Array Logical Drive Status Change. Logical drive number %5 on the array controller in %4 has a new status of %2.%n(Logical Drive status values: 1=other, 2=ok, 3=failed, 4=unconfigured, 5=recovering, 6=readyForRebuild, 7=rebuilding, 8=wrongDrive, 9=badConnect, 10=overheating, 11=shutdown, 12=expanding, 13=notAvailable, 14=queuedForExpansion)%n [SNMP TRAP: 3034 in CPQIDA.MIB] 1201 Warning Drive Array Spare Drive Status Change. The spare drive in %4, port %5, bay %6 has a new status of %2.%n(Spare status values: 1=other, 2=invalid, 3=failed, 4=inactive, 5=building, 6=active)%n [SNMP TRAP: 3035 in CPQIDA.MIB] 1202 Warning Drive Array Physical Drive Status Change. The physical drive in %4, port %5, bay %6 with serial number "%7", has a new status of %2.%n(Drive status values: 1=other, 2=ok, 3=failed, 4=predictiveFailure)%n [SNMP TRAP: 3036 in CPQIDA.MIB] 1203 Warning Drive Array Physical Drive Threshold Exceeded. The physical drive in %4, port %5, bay %6 with serial number "%7", has exceeded a drive threshold.%n [SNMP TRAP: 3037 in CPQIDA.MIB] Storage Agent Events 123

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

Event Description
Event Severity
Event ID
Storage System Temperature Status Change. An enclosure attached to port %5 of
storage system "%4" has a new temperature status of %7. The enclosure model is
"%6". %n(Temperature status values: 1=other, 2=noTemp, 3=ok, 4=degraded, 5=failed)
%n [SNMP TRAP: 8023 in CPQSTSYS.MIB]
Warning
1189
Storage System Power Supply Status Change. An enclosure attached to port %5 of
storage system "%4" has a new power supply status of %7. The enclosure model is
"%6". %n(Power supply status values: 1=other, 2=noFltTolPower, 3=ok, 4=degraded,
5=failed, 6=notSupported, 7=noFltTolPower-Bay1Missing,
8=noFltTolPower-Bay2Missing) %n [SNMP TRAP: 8024 in CPQSTSYS.MIB]
Warning
1190
SCSI Tape Library Status Change.%nThe tape library with SCSI target %6 connected
to SCSI bus %5 of the controller in slot %4 has a new status of %7.%n(Tape library
status values: 1=other, 2=ok, 3=degraded, 4=failed, 5=offline)%n [SNMP TRAP: 5018
in CPQSCSI.MIB]
Warning
1191
SCSI Tape Drive Status Change.%nThe tape drive with SCSI target %6 connected to
SCSI bus %5 of the controller in slot %4 has a new status of %2.%n(Tape drive status
values: 1=other, 2=ok, 3=failed, 5=offline, 6=missingWasOk, 7=missingWasFailed,
8=missingWasOffline)%n [SNMP TRAP: 5019 in CPQSCSI.MIB]
Warning
1192
External Tape Drive Status Change. The tape drive at location "%4", has a new status
of %7.%n(Tape drive status values: 1=other, 2=ok, 3=degraded, 4=failed, 5=offline,
6=missingWasOk, 7=missingWasOffline)%n [SNMP TRAP: 16023 in CPQFCA.MIB]
Warning
1193
External Tape Drive Cleaning Required. The tape drive at location "%4" requires
cleaning.%n [SNMP TRAP: 16024 in CPQFCA.MIB]
Warning
1194
External Tape Drive Replace Cleaning Tape. The cleaning tape in the tape drive at
location "%4" needs to be replaced.%n [SNMP TRAP: 16025 in CPQFCA.MIB]
Warning
1195
Storage System Recovery Server Option Status Change. Storage system "%4" has a
new RSO status of %5.%n(RSO status values: 1=other, 2=notSupported,
3=notConfigured, 4=disabled, 5=daemonDownDisabled, 6=ok, 7=daemonDownActive,
8=noSecondary, 9=daemonDownNoSecondary, 10=linkDown,
11=daemonDownLinkDown, 12=secondaryRunningAuto, 13=secondaryRunningUser,
14=evTimeoutError) %n [SNMP TRAP: 8025 in CPQSTSYS.MIB]
Warning
1196
External Tape Library Status Change. The tape library at location "%4", has a new
status of %7.%n(Library status values: 1=other, 2=ok, 3=degraded, 4=failed,
5=offline)%n [SNMP TRAP: 16026 in CPQFCA.MIB]
Warning
1197
External Tape Library Door Status Change. The tape library at location "%4", has a
new door status of %7.%n(Library door status values: 1=other, 2=notSupported,
3=closed, 4=open)%n [SNMP TRAP: 16027 in CPQFCA.MIB]
Warning
1198
Drive Array Controller Status Change. The Drive Array Controller in %7 has a new
status of %5.%n(Controller status values: 1=other, 2=ok, 3=generalFailure,
4=cableProblem, 5=poweredOff)%n [SNMP TRAP: 3033 in CPQIDA.MIB]
Warning
1199
Drive Array Logical Drive Status Change. Logical drive number %5 on the array
controller in %4 has a new status of %2.%n(Logical Drive status values: 1=other, 2=ok,
3=failed, 4=unconfigured, 5=recovering, 6=readyForRebuild, 7=rebuilding,
8=wrongDrive, 9=badConnect, 10=overheating, 11=shutdown, 12=expanding,
13=notAvailable, 14=queuedForExpansion)%n [SNMP TRAP: 3034 in CPQIDA.MIB]
Warning
1200
Drive Array Spare Drive Status Change. The spare drive in %4, port %5, bay %6 has
a new status of %2.%n(Spare status values: 1=other, 2=invalid, 3=failed, 4=inactive,
5=building, 6=active)%n [SNMP TRAP: 3035 in CPQIDA.MIB]
Warning
1201
Drive Array Physical Drive Status Change. The physical drive in %4, port %5, bay
%6 with serial number "%7", has a new status of %2.%n(Drive status values: 1=other,
2=ok, 3=failed, 4=predictiveFailure)%n [SNMP TRAP: 3036 in CPQIDA.MIB]
Warning
1202
Drive Array Physical Drive Threshold Exceeded. The physical drive in %4, port %5,
bay %6 with serial number "%7", has exceeded a drive threshold.%n [SNMP TRAP:
3037 in CPQIDA.MIB]
Warning
1203
Storage Agent Events