HP Integrity Superdome SX2000 Windows Integrity Management Agents Reference - Page 25
Failure to install a Partition level PDT. Probable Cause: Reset SNMP Trap
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Event ID Event Severity Event Description 5456 Error LBA Fatal Parity error encountered. Probable Cause: An LBA fatal parity error encountered. Recommended Action: Repair/replace the faulty hardware. SNMP Trap: hpevtIoLbaFatalParityErr - 5456 in HPIFPTRAP.MIB. 5457 Error LBA Fatal Timeout Error Encountered. Probable Cause: LBA fatal timeout error encountered. Recommended Action: Repair/replace the faulty hardware. SNMP Trap: hpevtIoLbaFatalTimeoutErr - 5457 in HPIFPTRAP.MIB. 5458 Error Misc Uncorrectable Error encountered. Probable Cause: A PCI card uncorrectable error was encountered. Recommended Action: Replace the faulty PCI card. SNMP Trap: hpevtIoDevAdapterMiscUncErr - 5458 in HPIFPTRAP.MIB. 5459 Error Misc fatal error discovered on PCI card Probable Cause: A fatal error was detected on a PCI card. Recommended Action: Repair/replace the faulty PCI card. SNMP Trap: hpevtIoDevAdapterMiscFatalErr - 5459 in HPIFPTRAP.MIB. 5464 Error DIMM SPD Extended Checksum Failure Probable Cause: Replace any bad dimms. SNMP Trap: hpevtMemDimmSpdExtendedChecksum - 5464 in HPIFPTRAP.MIB. 5467 Warning Options header checksum error encountered. Probable Cause: Reinitialize the options data. SNMP Trap: hpevtOptsHdrCksumError - 5467 in HPIFPTRAP.MIB. 5468 Warning Options data checksum error was encountered. Probable Cause: Verify options data and reinitialize if necessary. SNMP Trap: hpevtOptsDataCksumError - 5468 in HPIFPTRAP.MIB. 5473 Error Internal inconsistency in the interleave tables. Probable Cause: Reconfigure and Reset. SNMP Trap: hpevtPdMemIntlvWaysMismatch - 5473 in HPIFPTRAP.MIB. 5474 Warning CellInfoList is not NULL. Probable Cause: Reset. SNMP Trap: hpevtPdMemUnintlvdMemory - 5474 in HPIFPTRAP.MIB. 5478 Error Error in constructing the Memory Descriptor. Probable Cause: Reset. SNMP Trap: hpevtPdMemNoMemoryDesc - 5478 in HPIFPTRAP.MIB. 5479 Error Unable to update the local memory layout Probable Cause: Reset SNMP Trap: hpevtPdMemUpdateLocalCellFailed - 5479 in HPIFPTRAP.MIB. 5483 Error A required address was not found within a mapped address. Probable Cause: Reset SNMP Trap: hpevtPdMemPdtAddrNotFound - 5483 in HPIFPTRAP.MIB. 5485 Error Failure to install a Partition level PDT. Probable Cause: Reset SNMP Trap: hpevtPdMemPdtInstallFail - 5485 in HPIFPTRAP.MIB. 5490 Error A critical resource could not be found or is unusable Probable Cause: Determine the failing component or hardware from the data field as described and replace. SNMP Trap: hpevtUnusableResource - 5490 in HPIFPTRAP.MIB. 5491 Error Internal firmware programming error. Probable Cause: Report the IP to the firmware team. Reset the system. This cannot be worked around in the field. SNMP Trap: hpevtFwError - 5491 in HPIFPTRAP.MIB. 5492 Error NVRam test failed with a data compare error Probable Cause: Bad NVRam, replace the bad chip. SNMP Trap: hpevtNvramDataCmpError - 5492 in HPIFPTRAP.MIB. 5493 Error An NVRam CRC Error was detected Probable Cause: Firmware/software error Recommended Action: Check for new version of firmware/OS Contact HP Support SNMP Trap: hpevtNvramCrcError - 5493 in HPIFPTRAP.MIB. 5494 Warning The Error Response Mode has been determined Probable Cause: Decode the hex vales to ASCII to determine the mode. Other errors will determine action. SNMP Trap: hpevtErm - 5494 in HPIFPTRAP.MIB. 5496 Error A semaphore could not be obtained Probable Cause: Recommended Action: Reset system to clear the semaphore Try reinitializing NVRAM. If problem persists, contact engineering. SNMP Trap: hpevtErrorObtainingSemaphore - 5496 in HPIFPTRAP.MIB. Platform Agent Events 25