HP Integrity Superdome SX2000 Windows Integrity Management Agents Reference - Page 50

to the same XBC. Check CC, Check XBC, Contact HP Support Personnel. SNMP Trap

Page 50 highlights

Event ID Event Severity Event Description 8205 Warning Testing of correctable errors injected from the CC has failed Probable Cause: Either the CC failed to inject the errors, the XBC failed to detect them, or PDC could not access the XBC CSR. Recommended Action: Check results from other cells connected to the same XBC. Check CC, Check XBC, Contact HP Support Personnel. SNMP Trap: hpevtFabricLinkCorErrTestFailure - 8205 in HPIFPTRAP.MIB. 8206 Error A cabinet has been configured using an invalid cabinet number Probable Cause: Re-configure cabinet to use a valid cabinet number SNMP Trap: hpevtInvalidCabinetNumber - 8206 in HPIFPTRAP.MIB. 8207 Error Cells trying to join a PD are at incompatible firmware revisions Probable Cause: The reporting cell is at a different firmware revision than the cell reported in the data field. A PD cannot be established. Please reprogram the 2 cells to the same firmware revision. SNMP Trap: hpevtPdIncompatibleFwRevs - 8207 in HPIFPTRAP.MIB. 8212 Warning An attempt to write to a device on the PM's I2C bus has failed. Probable Cause: A hardware error has occurred. Recommended Action: Replace the UGUY board. SNMP Trap: hpevtPmI2cWriteFailed - 8212 in HPIFPTRAP.MIB. 8214 Warning An attempt to read from a device on the PM's I2C bus has failed. Probable Cause: A hardware error has occurred. Recommended Action: Replace the UGUY board. SNMP Trap: hpevtPmI2cReadFailed - 8214 in HPIFPTRAP.MIB. 8216 Warning An error was encountered updating the cell info structure in ICM Probable Cause: This should not happen. Contact engineering to diagnose the problem. SNMP Trap: hpevtCellInfoError - 8216 in HPIFPTRAP.MIB. 8218 Warning An error was encountered pointing the slave cell consoles to the diva Probable Cause: A CPU on the slave cell could not process an interrupt in time or establish the diva console. SNMP Trap: hpevtSlaveConsoleSetupError - 8218 in HPIFPTRAP.MIB. 8219 Error An error was encountered trying to relocate a slave cells registry Probable Cause: There could be a PD rendezvous error or a processor on the slave cell failed to respond to an interrupt in time. SNMP Trap: hpevtRegistryMoveToCoreCellError - 8219 in HPIFPTRAP.MIB. 8220 Error Complex Profile Group C CRC didn't match the expected value Probable Cause: Push out a new Group C complex profile. SNMP Trap: hpevtProfileGroupCCrcError - 8220 in HPIFPTRAP.MIB. 8238 Error Failure to identify a core cell during Global MCA. Probable Cause: This will lead to a system reset. SNMP Trap: hpevtMcCoreCellSelectFail - 8238 in HPIFPTRAP.MIB. 8239 Warning Unexpected fabric firmware error Probable Cause: An unanticipated error occurred. Contact HP Support personnel to analyze the IPMI FPL log. SNMP Trap: hpevtFabricAssertFabricUtils - 8239 in HPIFPTRAP.MIB. 8240 Error Internal firmware programming error in the PMI handler. Probable Cause: Report the IP to the firmware team. Reset the system. This cannot be worked around in the field. SNMP Trap: hpevtSalPmiFwError - 8240 in HPIFPTRAP.MIB. 8243 Error During a Cell On Line Add inconsistent number of cells discovered Probable Cause: This can be caused by inconsistent profile information. This can also occur when an expected cell did not make the original boot of the partition. Update the complex profile to all the cells with a correct view of the system and try to add the cell again. SNMP Trap: hpevtOlaWrongNumberCells - 8243 in HPIFPTRAP.MIB. 8257 Warning Error reading source cell port on XBC during data traversability test Probable Cause: A read error most likely occurred. Look for preceding chassis codes to determine exact cause. SNMP Trap: hpevtFabricXbcRouteSourceCellPortErr - 8257 in HPIFPTRAP.MIB. 8261 Warning OLA cell is incompatible with the existing partition Probable Cause: OLA cell has incompatible resources. Recommended Action: Change the resources on the cell to be compatible with the existing partition or attempt to OLA a different cell. SNMP Trap: hpevtBootOlaCellIncompatible - 8261 in HPIFPTRAP.MIB. 50 Management Agents Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

Event Description
Event Severity
Event ID
Testing of correctable errors injected from the CC has failed Probable Cause: Either
the CC failed to inject the errors, the XBC failed to detect them, or PDC could not
access the XBC CSR. Recommended Action: Check results from other cells connected
to the same XBC. Check CC, Check XBC, Contact HP Support Personnel. SNMP Trap:
hpevtFabricLinkCorErrTestFailure - 8205 in HPIFPTRAP.MIB.
Warning
8205
A cabinet has been configured using an invalid cabinet number Probable Cause:
Re-configure cabinet to use a valid cabinet number SNMP Trap:
hpevtInvalidCabinetNumber - 8206 in HPIFPTRAP.MIB.
Error
8206
Cells trying to join a PD are at incompatible firmware revisions Probable Cause: The
reporting cell is at a different firmware revision than the cell reported in the data
field. A PD cannot be established. Please reprogram the 2 cells to the same firmware
revision. SNMP Trap: hpevtPdIncompatibleFwRevs - 8207 in HPIFPTRAP.MIB.
Error
8207
An attempt to write to a device on the PM's I2C bus has failed. Probable Cause: A
hardware error has occurred. Recommended Action: Replace the UGUY board. SNMP
Trap: hpevtPmI2cWriteFailed - 8212 in HPIFPTRAP.MIB.
Warning
8212
An attempt to read from a device on the PM's I2C bus has failed. Probable Cause: A
hardware error has occurred. Recommended Action: Replace the UGUY board. SNMP
Trap: hpevtPmI2cReadFailed - 8214 in HPIFPTRAP.MIB.
Warning
8214
An error was encountered updating the cell info structure in ICM Probable Cause:
This should not happen. Contact engineering to diagnose the problem. SNMP Trap:
hpevtCellInfoError - 8216 in HPIFPTRAP.MIB.
Warning
8216
An error was encountered pointing the slave cell consoles to the diva Probable Cause:
A CPU on the slave cell could not process an interrupt in time or establish the diva
console. SNMP Trap: hpevtSlaveConsoleSetupError - 8218 in HPIFPTRAP.MIB.
Warning
8218
An error was encountered trying to relocate a slave cells registry Probable Cause:
There could be a PD rendezvous error or a processor on the slave cell failed to respond
to an interrupt in time. SNMP Trap: hpevtRegistryMoveToCoreCellError - 8219 in
HPIFPTRAP.MIB.
Error
8219
Complex Profile Group C CRC didn't match the expected value Probable Cause:
Push out a new Group C complex profile. SNMP Trap: hpevtProfileGroupCCrcError
- 8220 in HPIFPTRAP.MIB.
Error
8220
Failure to identify a core cell during Global MCA. Probable Cause: This will lead to
a system reset. SNMP Trap: hpevtMcCoreCellSelectFail - 8238 in HPIFPTRAP.MIB.
Error
8238
Unexpected fabric firmware error Probable Cause: An unanticipated error occurred.
Contact HP Support personnel to analyze the IPMI FPL log. SNMP Trap:
hpevtFabricAssertFabricUtils - 8239 in HPIFPTRAP.MIB.
Warning
8239
Internal firmware programming error in the PMI handler. Probable Cause: Report
the IP to the firmware team. Reset the system. This cannot be worked around in the
field. SNMP Trap: hpevtSalPmiFwError - 8240 in HPIFPTRAP.MIB.
Error
8240
During a Cell On Line Add inconsistent number of cells discovered Probable Cause:
This can be caused by inconsistent profile information. This can also occur when an
expected cell did not make the original boot of the partition. Update the complex
profile to all the cells with a correct view of the system and try to add the cell again.
SNMP Trap: hpevtOlaWrongNumberCells - 8243 in HPIFPTRAP.MIB.
Error
8243
Error reading source cell port on XBC during data traversability test Probable Cause:
A read error most likely occurred. Look for preceding chassis codes to determine
exact cause. SNMP Trap: hpevtFabricXbcRouteSourceCellPortErr - 8257 in
HPIFPTRAP.MIB.
Warning
8257
OLA cell is incompatible with the existing partition Probable Cause: OLA cell has
incompatible resources. Recommended Action: Change the resources on the cell to
be compatible with the existing partition or attempt to OLA a different cell. SNMP
Trap: hpevtBootOlaCellIncompatible - 8261 in HPIFPTRAP.MIB.
Warning
8261
50
Management Agents Event Tables