Windows: Predictive Failure in Memory Warning Probable Cause: You will receive

Page 68 highlights

Event ID Event Severity Event Description 9710 Warning The core cell selected is not in the rendezvoused partition Probable Cause: Configuration error, main backplane failure; the intended core cell failed during boot. Recommended Action: check partition configuration, check for failed cells, check for additional chassis codes indicating more failure detail. SNMP Trap: hpevtBootFindCoreCellNotInRendez - 9710 in HPIFPTRAP.MIB. 9711 Warning The local cell is not viable Probable Cause: Configuration error, main backplane failure; no viable core cell. Recommended Action: check partition configuration, attach core I/O to local cell, make sure a viable core cell is configured within the partition. SNMP Trap: hpevtBootFindCoreCellLclNotViable - 9711 in HPIFPTRAP.MIB. 9712 Warning cell cannot reach the fabric, partition contains 3 or more cells Probable Cause: configuration combined with main backplane problems. Recommended Action: Contact HP Support to confirm the main backplane is functioning properly. Change the partition configuration to only contain 1 or 2 cells. SNMP Trap: hpevtBootFindCoreCellFabriclessPdErr - 9712 in HPIFPTRAP.MIB. 9719 Warning The RTC is providing inconsistent data. Probable Cause: there is a known issue with some Dallas Semiconductor DS1501 RTC parts that can cause read data anomalies but they should never be this consistent, this event indicates faulty PDH hardware. Recommended Action: replace the PDH hardware. SNMP Trap: hpevtRtcAccessError - 9719 in HPIFPTRAP.MIB. 9727 Error PDC failed to read the processor architecture for another cell in the partition Probable Cause: PDC was unable to read a data structure for another cell in the partition. This should never happen unless there is an intermittent problem with the main backplane. Recommended Action: Contact HP support to confirm that the main backplane is functioning properly. SNMP Trap: hpevtBootAccessCellArchErr - 9727 in HPIFPTRAP.MIB. 9740 Error The buffer size is too small for the XBC error log Probable Cause: Firmware error. Recommended Action: Reset cell. SNMP Trap: hpevtXbcLogSizeErr - 9740 in HPIFPTRAP.MIB. 9741 Error System firmware was unable to clear an XBC error Probable Cause: The particular XBC and port could have a persistent error. Recommended Action: Check flex cable indicated by event data. SNMP Trap: hpevtXbcLogClearErr - 9741 in HPIFPTRAP.MIB. 9744 Error Error encountered while collecting PCI error logs Probable Cause: An error occurred while collecting the PCI error logs Recommended Action: No action can be taken. The result is some or all PCI error logs will be unavailable. SNMP Trap: hpevtIodiscPciLogError - 9744 in HPIFPTRAP.MIB. 9745 Error Error encountered while collecting SBA error logs Probable Cause: An error occurred while collecting the SBA error logs Recommended Action: No action can be taken. The result is some or all SBA error logs will be unavailable. SNMP Trap: hpevtIodiscSbaLogError - 9745 in HPIFPTRAP.MIB. 9746 Error Fabric is unable to route the crossbar after multiple retry attempts Probable Cause: Hardware problem. Possible bad XBC or Cell Controller Recommended Action: Check for hardware failures. Reset backplane to re-initialize fabric. SNMP Trap: hpevtXbcInitMaxRetries - 9746 in HPIFPTRAP.MIB. 9750 Warning Windows: Predictive Failure in Memory (Warning) Probable Cause: You will receive this message if the system is correcting a lot of ECC single bit errors. It may mean that the module is about to fail, or environmental conditions in the server are causing more errors than usual. This event message will be generated for one of the following conditions 1000 single-bit errors on the same address in a 48 hour time period. 50 single-bit errors on the same DIMM (not the same address) in a 24 hour time period. 100 single-bit errors on the same DIMM (not the same address) in a 1 week time period. Recommended Action: If you receive this message, contact your support provider to determine if a predictive repair should be made. SNMP Trap: hpevtWinAgtPredictMemFailWarning - 9750 in HPIFPTRAP.MIB. 68 Management Agents Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

Event Description
Event Severity
Event ID
The core cell selected is not in the rendezvoused partition Probable Cause:
Configuration error, main backplane failure; the intended core cell failed during
boot. Recommended Action: check partition configuration, check for failed cells,
check for additional chassis codes indicating more failure detail. SNMP Trap:
hpevtBootFindCoreCellNotInRendez - 9710 in HPIFPTRAP.MIB.
Warning
9710
The local cell is not viable Probable Cause: Configuration error, main backplane
failure; no viable core cell. Recommended Action: check partition configuration,
attach core I/O to local cell, make sure a viable core cell is configured within the
partition. SNMP Trap: hpevtBootFindCoreCellLclNotViable - 9711 in
HPIFPTRAP.MIB.
Warning
9711
cell cannot reach the fabric, partition contains 3 or more cells Probable Cause:
configuration combined with main backplane problems. Recommended Action:
Contact HP Support to confirm the main backplane is functioning properly. Change
the partition configuration to only contain 1 or 2 cells. SNMP Trap:
hpevtBootFindCoreCellFabriclessPdErr - 9712 in HPIFPTRAP.MIB.
Warning
9712
The RTC is providing inconsistent data. Probable Cause: there is a known issue with
some Dallas Semiconductor DS1501 RTC parts that can cause read data anomalies
but they should never be this consistent, this event indicates faulty PDH hardware.
Recommended Action: replace the PDH hardware. SNMP Trap: hpevtRtcAccessError
- 9719 in HPIFPTRAP.MIB.
Warning
9719
PDC failed to read the processor architecture for another cell in the partition Probable
Cause: PDC was unable to read a data structure for another cell in the partition. This
should never happen unless there is an intermittent problem with the main backplane.
Recommended Action: Contact HP support to confirm that the main backplane is
functioning properly. SNMP Trap: hpevtBootAccessCellArchErr - 9727 in
HPIFPTRAP.MIB.
Error
9727
The buffer size is too small for the XBC error log Probable Cause: Firmware error.
Recommended Action: Reset cell. SNMP Trap: hpevtXbcLogSizeErr - 9740 in
HPIFPTRAP.MIB.
Error
9740
System firmware was unable to clear an XBC error Probable Cause: The particular
XBC and port could have a persistent error. Recommended Action: Check flex cable
indicated by event data. SNMP Trap: hpevtXbcLogClearErr - 9741 in HPIFPTRAP.MIB.
Error
9741
Error encountered while collecting PCI error logs Probable Cause: An error occurred
while collecting the PCI error logs Recommended Action: No action can be taken.
The result is some or all PCI error logs will be unavailable. SNMP Trap:
hpevtIodiscPciLogError - 9744 in HPIFPTRAP.MIB.
Error
9744
Error encountered while collecting SBA error logs Probable Cause: An error occurred
while collecting the SBA error logs Recommended Action: No action can be taken.
The result is some or all SBA error logs will be unavailable. SNMP Trap:
hpevtIodiscSbaLogError - 9745 in HPIFPTRAP.MIB.
Error
9745
Fabric is unable to route the crossbar after multiple retry attempts Probable Cause:
Hardware problem. Possible bad XBC or Cell Controller Recommended Action:
Check for hardware failures. Reset backplane to re-initialize fabric. SNMP Trap:
hpevtXbcInitMaxRetries - 9746 in HPIFPTRAP.MIB.
Error
9746
Windows: Predictive Failure in Memory (Warning) Probable Cause: You will receive
this message if the system is correcting a lot of ECC single bit errors. It may mean
that the module is about to fail, or environmental conditions in the server are causing
more errors than usual. This event message will be generated for one of the following
conditions 1000 single-bit errors on the same address in a 48 hour time period. 50
single-bit errors on the same DIMM (not the same address) in a 24 hour time period.
100 single-bit errors on the same DIMM (not the same address) in a 1 week time
period. Recommended Action: If you receive this message, contact your support
provider to determine if a predictive repair should be made. SNMP Trap:
hpevtWinAgtPredictMemFailWarning - 9750 in HPIFPTRAP.MIB.
Warning
9750
68