HP Integrity Superdome SX2000 Windows Integrity Management Agents Reference - Page 78
System FW was unable to access the XBC semaphore. Probable Cause: System FW
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
Event ID Event Severity Event Description 10481 Warning System Firmware was unable to access the configured set stored in the complex profile. Probable Cause: SFW was unable to access the configured set stored in the complex profile. Recommended Action: Collect IPMI events and contact your HP Support Representative. SNMP Trap: hpevtSysFwUnAccesComplxProf - 10481 in HPIFPTRAP.MIB. 10482 Warning System Firmware detected an error during Fabric Init. Probable Cause: Error detected by SFW during Fabric Init. Recommended Action: Collect IMPI events and contact your HP Support Representative for assistance. SNMP Trap: hpevtSysFwDetctErrFabInit - 10482 in HPIFPTRAP.MIB. 10483 Warning System Firmware detected a failure during Fabric Init. Probable Cause: Failure detected by SFW during Fabric Init. Recommended Action: Collect IPMI events and contact your HP Support Representative for assistance. SNMP Trap: hpevtSysFwDetctFailFabInit - 10483 in HPIFPTRAP.MIB. 10487 Warning System Firmware detected an error during Fabric Optimize. Probable Cause: Error detected by SFW during Fabric Optimize. Recommended Action: Collect IMPI events and contact your HP Support Representative for assistance. SNMP Trap: hpevtSysFwDetctErrFabOptimz - 10487 in HPIFPTRAP.MIB. 10489 Warning Input power to the specified UPS has failed. SNMP Trap: hpevtInPwrUPSFail - 10489 in HPIFPTRAP.MIB. 10490 Warning Input power to the specified UPS has been restored. SNMP Trap: hpevtUpsRestored - 10490 in HPIFPTRAP.MIB. 10495 Error UPS power exhausted. The system is being powered down. SNMP Trap: hpevtUpsExhausted - 10495 in HPIFPTRAP.MIB. 10509 Warning During Machine Check handling, SAL failed to rendezvous all the processors. Probable Cause: System firmware cannot roundup the processors during the machine check handler. Recommended Action: Check for faulty processor, possibly the one(s) that failed to rendezvous. Contact your HP representative for support. SNMP Trap: hpevtSALFailRedzvsProcs - 10509 in HPIFPTRAP.MIB. 10510 Warning SAL failed to clear the CEC logs during Machine check handling. Probable Cause: System firmware failed to clear the CEC logs. Recommended Action: Check for multiple errors or bad CEC. Contact your HP representative for support. SNMP Trap: hpevtSALFailClrCECLog - 10510 in HPIFPTRAP.MIB. 10516 Warning System FW was unable to access the XBC semaphore. Probable Cause: System FW was unable to access the XBC semaphore. Recommended Action: Collect IPMI events, look for additional errors events, and contact HP support for assistance. SNMP Trap: hpevtSysFwUnAccesXBCSemphr - 10516 in HPIFPTRAP.MIB. 10518 Warning System Firmware detected an error while trying to release the XBC Global Semaphore. Probable Cause: Error detected by SFW while trying to release the XBC Global Semaphore. Recommended Action: Collect IPMI events and contact your HP Support Representative. SNMP Trap: hpevtSysFwDetctErrRelXBCGlobSemphr - 10518 in HPIFPTRAP.MIB. 10519 Warning System Firmware detected an Error while checking the owner of the XBC Global Semaphore. Probable Cause: Error detected by SFW while checking the owner of the XBC Global Semaphore. Recommended Action: Collect IMPI events and contact your HP Support Representative. SNMP Trap: hpevtSysFwDetctErrOwnXBCGlobSemphr - 10519 in HPIFPTRAP.MIB. 10520 Warning An error occurred while forming the XBC semaphore address Probable Cause: Couldn't determine the proper address of the XBC semaphore Recommended Action: Save IPMI event codes, contact HP Support Representative to analyze the fabric SNMP Trap: hpevtErrFormXbcSemphrAddr - 10520 in HPIFPTRAP.MIB. 10521 Warning Error reading the XBC Global Semaphore Probable Cause: Couldn't read the XBC semaphore Recommended Action: Look for additional IPMI event logs, contact your HP support representative to analyze the fabric SNMP Trap: hpevtErrRdXbcGlobSemphr - 10521 in HPIFPTRAP.MIB. 78 Management Agents Event Tables