HP Integrity Superdome SX2000 Windows Integrity Management Agents Reference - Page 72
Uncorrectable PAA fault on MX2 Probable Cause: An uncorrectable PAA fault has
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
Event ID Event Severity Event Description 10060 Warning The left cell latch is open. SNMP Trap: hpevtCellLatchOpen - 10060 in HPIFPTRAP.MIB. 10061 Warning Right ejector latch is open Probable Cause: The right ejector latch is open. Recommended Action: Close the right ejector latch on the specified cell. SNMP Trap: hpevtDcnfgRightCellLatch - 10061 in HPIFPTRAP.MIB. 10062 Warning The optical emitters on the cell latch sensors are not functioning Probable Cause: There is a hardware failure. Recommended Action: The cell board must be repaired or replaced. SNMP Trap: hpevtCellLatchSensorBad - 10062 in HPIFPTRAP.MIB. 10063 Warning The vrm on the specified cell is reporting a voltage fault. Probable Cause: The specified vrm is reporting a fault. Recommended Action: Replace the specified VRM. The datafield contains the physical location. Byte 16 is the cabinet, byte 13 is the cell slot, and byte 11 is the vrm slot. The vrm slot in byte 11 matches the vrm number silkscreened on the cell board. SNMP Trap: hpevtVrmVltFault - 10063 in HPIFPTRAP.MIB. 10064 Warning The vrm on the specified cell is reporting a temperature fault. SNMP Trap: hpevtVrmTempFlt - 10064 in HPIFPTRAP.MIB. 10065 Warning The rail on a cell is reporting a fault. SNMP Trap: hpevtVrmFlt - 10065 in HPIFPTRAP.MIB. 10068 Warning A I/O backplane vrm is reporting a voltage fault. SNMP Trap: hpevtVrmIoVltFlt 10068 in HPIFPTRAP.MIB. 10069 Warning A I/O backplane power brick is reporting a voltage fault. SNMP Trap: hpevtPwrBrickVltFlt - 10069 in HPIFPTRAP.MIB. 10070 Warning A I/O backplane vrm is reporting a temperature fault. SNMP Trap: hpevtVrmBkPlaneTempFlt - 10070 in HPIFPTRAP.MIB. 10071 Warning A I/O backplane power brick is reporting a temperature fault. SNMP Trap: hpevtBkPlanePwrBrickTempFlt - 10071 in HPIFPTRAP.MIB. 10072 Warning A I/O backplane vrm rail is reporting a fault. SNMP Trap: hpevtBkPlanVrmRailFlt - 10072 in HPIFPTRAP.MIB. 10073 Warning A I/O backplane power brick is reporting a rail fault. SNMP Trap: hpevtBkPlanePwrBrkFlt - 10073 in HPIFPTRAP.MIB. 10103 Warning The specified system backplane vrm is reporting a module voltage fault. SNMP Trap: hpevtBkPlaneVrmVltFlt - 10103 in HPIFPTRAP.MIB. 10104 Warning The specified system backplane vrm is reporting a temperature fault. SNMP Trap: hpevtBkPlaneVrmTempFlt - 10104 in HPIFPTRAP.MIB. 10105 Warning The specified system backplane rail is reporting a fault SNMP Trap: hpevtBkPlaneFlt - 10105 in HPIFPTRAP.MIB. 10115 Warning Master MP failure. Slave MP has taken control SNMP Trap: hpevtMstrMpFailed 10115 in HPIFPTRAP.MIB. 10116 Error The NVRAM service was unable to satisfy an NVRAM allocation request Probable Cause: NVRAM is full. This is extremely unlikely. Recommended Action: Clear NVRAM and reset. SNMP Trap: hpevtNvramAlloc - 10116 in HPIFPTRAP.MIB. 10132 Error The RTC not updating its internal time registers Probable Cause: Bad RTC chip on the PDH daughtercard. Recommended Action: Replace PDH daughtercard SNMP Trap: hpevtRtcTimeReg - 10132 in HPIFPTRAP.MIB. 10159 Warning Uncorrectable PAA fault on MX2 Probable Cause: An uncorrectable PAA fault has occurred on the MX2 module and PAA firmware has halted. Recommended Action: Contact your HP support personnel. SNMP Trap: hpevtPAAFltMx2 - 10159 in HPIFPTRAP.MIB. 72 Management Agents Event Tables