HP Integrity Superdome SX2000 Windows Integrity Management Agents Reference - Page 56
Could not initialize the CC to CC link upon boot. Probable Cause: CC CSR Access
View all HP Integrity Superdome SX2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
Event ID Event Severity Event Description 8860 Warning This means that the registry sanity check failed during MCA error handling. Probable Cause: The cells will independently log errors and reset. SNMP Trap: hpevtMcRegistryCheckFailed - 8860 in HPIFPTRAP.MIB. 8861 Warning This means that MCA occurred while OS_MCA was performing error recovery. Probable Cause: The cells will log information and reset. SNMP Trap: hpevtMcDuringOsMca - 8861 in HPIFPTRAP.MIB. 8864 Warning One of the BT errors occurred that results in abandoning memory dump. Probable Cause: A machine check has occurred and cells have not rendezvoused. Recommended Action: Cells will reset themselves. SNMP Trap: hpevtMcMemDumpAbandon - 8864 in HPIFPTRAP.MIB. 8865 Warning The firmware tree is not complete and hence there will be no PD rendezvous. Probable Cause: The cell will log errors and reset SNMP Trap: hpevtMcFwTreeNotComplete - 8865 in HPIFPTRAP.MIB. 8872 Error ACPI configuration mismatch across cells in the partition Probable Cause: Set the ACPI configuration parameter again to ensure that all cells have a consistent value. SNMP Trap: hpevtAcpiConfigMismatch - 8872 in HPIFPTRAP.MIB. 8873 Error Failed clearing of the XIN_ERR_ORDER_STATUS CSR Probable Cause: Failure to access the register or the write did not work. Recommended Action: Contact HP Support personnel to check the CC. SNMP Trap: hpevtFabricXinErrOrderStatusClrFailed - 8873 in HPIFPTRAP.MIB. 8876 Warning Unexpected fabric firmware error Probable Cause: An unanticipated error occurred. Contact HP Support personnel to analyze the IPMI FPL log. SNMP Trap: hpevtFabricAssertFabricInit - 8876 in HPIFPTRAP.MIB. 8877 Warning Invalid data read from a CPU module's Processor Information ROM. Probable Cause: The CPU module's Processor Information ROM is unprogrammed. Recommended Action: Contact HP support personnel to troubleshoot the CPU module pointed to by the physical location portion of this event. SNMP Trap: hpevtInvalidPiromData - 8877 in HPIFPTRAP.MIB. 8882 Warning Invalid parameter when setting cpu frequency ratios Probable Cause: Specify a valid parameter. SNMP Trap: hpevtSettingFreqRatiosError - 8882 in HPIFPTRAP.MIB. 8883 Warning Option block in nvram has a checksum error Probable Cause: Clear NVRAM. SNMP Trap: hpevtOptsBlockCksumError - 8883 in HPIFPTRAP.MIB. 8894 Warning CC to CC link did not initialize on the local cell Probable Cause: link failure between the XBC and the CC Recommended Action: Check CC. SNMP Trap: hpevtFabricColaLocalCcLinkNotInit - 8894 in HPIFPTRAP.MIB. 8895 Warning Failed to write the CC link disable register Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to analyze the fabric. SNMP Trap: hpevtFabricXinInitDisableWrError - 8895 in HPIFPTRAP.MIB. 8896 Warning An unknown backplane type was found Probable Cause: CSR Read/Write error Recommended Action: Contact HP Support personnel to analyze the fabric. SNMP Trap: hpevtFabricXinErrMaskUnknownBkp - 8896 in HPIFPTRAP.MIB. 8897 Warning Error writing the CC link error mask Probable Cause: Fabric Access Error. Recommended Action: Contact HP Support personnel to analyze the fabric. SNMP Trap: hpevtFabricXinWrErrMaskError - 8897 in HPIFPTRAP.MIB. 8898 Warning Failed to read the CC's fabric link error mask Probable Cause: CC CSR access failure. Recommended Action: Contact HP Support personnel to analyze the fabric. SNMP Trap: hpevtFabricXinRdErrMaskError - 8898 in HPIFPTRAP.MIB. 8900 Error Could not initialize the CC to CC link upon boot. Probable Cause: CC CSR Access Failure. Recommended Action: Contact HP Support personnel to analyze the fabric. SNMP Trap: hpevtFabricInitCcLinkFailure - 8900 in HPIFPTRAP.MIB. 8906 Warning An Error occurred trying to notify the MP of the attempted reset. Probable Cause: The MP is not functioning or the PDHC cannot communicate with it. Reset the MP. SNMP Trap: hpevtResetCommandError - 8906 in HPIFPTRAP.MIB. 56 Management Agents Event Tables