HP Integrity Superdome SX2000 Windows Integrity Management Agents Reference - Page 37

OS legacy PA hex fault code Bxxx Probable Cause: fault/panic SNMP Trap

Page 37 highlights

Event ID Event Severity Event Description 5800 Error CPUs running at different speeds were detected during rendezvous Probable Cause: Reconfigure the PD so that all cells have processors running at the same speed. SNMP Trap: hpevtPdIncompatibleCpuSpeeds - 5800 in HPIFPTRAP.MIB. 5802 Error The link between the local CC and the local XBC is unexpectedly not initialized. Probable Cause: An error initializing fabric Recommended Action: A previously reported event may provide exact detailsReboot, if failure persists, then either replace the CC chip or the system backplane. SNMP Trap: hpevtFabricCellLinkNotInit - 5802 in HPIFPTRAP.MIB. 5803 Error An invalid XBC number was given. Probable Cause: Firmware error Recommended Action: Reset cell SNMP Trap: hpevtFabricInvalidXbcNum - 5803 in HPIFPTRAP.MIB. 5804 Error An invalid XBC port number was given. Probable Cause: Firmware error Recommended Action: Reset cell SNMP Trap: hpevtFabricInvalidXbcPortNum - 5804 in HPIFPTRAP.MIB. 5805 Warning A bad parameter was passed to the LED function in the utilities component Probable Cause: Contact FW engineering. This is a bug. SNMP Trap: hpevtUtilitiesLedParamError - 5805 in HPIFPTRAP.MIB. 5806 Error An unexpected neighbor type was read from a XBC PORT_NEIGHBOR_INFO CSR. Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset cell. SNMP Trap: hpevtFabricUnexpectedNtype - 5806 in HPIFPTRAP.MIB. 5807 Error A given XBC port is not a valid XBC-CC port. Probable Cause: Firmware error. Recommended Action: Reset cell SNMP Trap: hpevtFabricPortNotCc - 5807 in HPIFPTRAP.MIB. 5808 Error A XBC port was unexpectedly found to be an invalid XBC-XBC port. Probable Cause: Firmware error. Recommended Action: Reset cell. SNMP Trap: hpevtFabricPortNotXbc - 5808 in HPIFPTRAP.MIB. 5809 Error The XBC neighbor chip number does not match the expected value for this topology Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset cell. SNMP Trap: hpevtFabricUnexpectedNChip - 5809 in HPIFPTRAP.MIB. 5810 Error The XBC neighbor port number does not match the expected value for this topology Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset cell. SNMP Trap: hpevtFabricUnexpectedNPort - 5810 in HPIFPTRAP.MIB. 5811 Warning Write through to BMC token failed Probable Cause: Problem accessing the BMC. Recommended Action: Reset BMC or reboot. Upgrade BMC FW and System FW. If problem persists, contact your HP representative for support. SNMP Trap: hpevtBootNvmWriteToBmcTokenFailure - 5811 in HPIFPTRAP.MIB. 5812 Warning Utilities reported an error while trying to manipulate the LED Probable Cause: It is likely the GSP is not present or the device specified is not present. Solve these problems and try again. SNMP Trap: hpevtUtilitiesLedError - 5812 in HPIFPTRAP.MIB. 5813 Error Duplicate Cpu Ids were detected within a cell. Probable Cause: Most likely cause is a bad cpu module connection on the cell board. Replace the cell board. SNMP Trap: hpevtDuplicateCpuIds - 5813 in HPIFPTRAP.MIB. 5823 Warning OS crashdump started (D700) Probable Cause: panic occurred SNMP Trap: hpevtHp-uxCrashdumpStarted - 5823 in HPIFPTRAP.MIB. 5824 Error OS legacy PA hex fault code (Bxxx) Probable Cause: fault/panic SNMP Trap: hpevtHp-uxHexFaultCode - 5824 in HPIFPTRAP.MIB. 5825 Warning OS dump status (EFxx) Probable Cause: panic, mca, or INIT path: attempt to write out the dump is complete Recommended Action: No action required SNMP Trap: hpevtHp-uxDumpStatus - 5825 in HPIFPTRAP.MIB. 5827 Warning Setting processor response timeout failed Probable Cause: A PAL call made by SFW has failed. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. SNMP Trap: hpevtSettingProcTimeoutFail - 5827 in HPIFPTRAP.MIB. Platform Agent Events 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

Event Description
Event Severity
Event ID
CPUs running at different speeds were detected during rendezvous Probable Cause:
Reconfigure the PD so that all cells have processors running at the same speed. SNMP
Trap: hpevtPdIncompatibleCpuSpeeds - 5800 in HPIFPTRAP.MIB.
Error
5800
The link between the local CC and the local XBC is unexpectedly not initialized.
Probable Cause: An error initializing fabric Recommended Action: A previously
reported event may provide exact detailsReboot, if failure persists, then either replace
the CC chip or the system backplane. SNMP Trap: hpevtFabricCellLinkNotInit - 5802
in HPIFPTRAP.MIB.
Error
5802
An invalid XBC number was given. Probable Cause: Firmware error Recommended
Action: Reset cell SNMP Trap: hpevtFabricInvalidXbcNum - 5803 in HPIFPTRAP.MIB.
Error
5803
An invalid XBC port number was given. Probable Cause: Firmware error
Recommended Action: Reset cell SNMP Trap: hpevtFabricInvalidXbcPortNum - 5804
in HPIFPTRAP.MIB.
Error
5804
A bad parameter was passed to the LED function in the utilities component Probable
Cause: Contact FW engineering. This is a bug. SNMP Trap:
hpevtUtilitiesLedParamError - 5805 in HPIFPTRAP.MIB.
Warning
5805
An unexpected neighbor type was read from a XBC PORT_NEIGHBOR_INFO CSR.
Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset
cell. SNMP Trap: hpevtFabricUnexpectedNtype - 5806 in HPIFPTRAP.MIB.
Error
5806
A given XBC port is not a valid XBC-CC port. Probable Cause: Firmware error.
Recommended Action: Reset cell SNMP Trap: hpevtFabricPortNotCc - 5807 in
HPIFPTRAP.MIB.
Error
5807
A XBC port was unexpectedly found to be an invalid XBC-XBC port. Probable Cause:
Firmware error. Recommended Action: Reset cell. SNMP Trap:
hpevtFabricPortNotXbc - 5808 in HPIFPTRAP.MIB.
Error
5808
The XBC neighbor chip number does not match the expected value for this topology
Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset
cell. SNMP Trap: hpevtFabricUnexpectedNChip - 5809 in HPIFPTRAP.MIB.
Error
5809
The XBC neighbor port number does not match the expected value for this topology
Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset
cell. SNMP Trap: hpevtFabricUnexpectedNPort - 5810 in HPIFPTRAP.MIB.
Error
5810
Write through to BMC token failed Probable Cause: Problem accessing the BMC.
Recommended Action: Reset BMC or reboot. Upgrade BMC FW and System FW. If
problem persists, contact your HP representative for support. SNMP Trap:
hpevtBootNvmWriteToBmcTokenFailure - 5811 in HPIFPTRAP.MIB.
Warning
5811
Utilities reported an error while trying to manipulate the LED Probable Cause: It is
likely the GSP is not present or the device specified is not present. Solve these
problems and try again. SNMP Trap: hpevtUtilitiesLedError - 5812 in
HPIFPTRAP.MIB.
Warning
5812
Duplicate Cpu Ids were detected within a cell. Probable Cause: Most likely cause is
a bad cpu module connection on the cell board. Replace the cell board. SNMP Trap:
hpevtDuplicateCpuIds - 5813 in HPIFPTRAP.MIB.
Error
5813
OS crashdump started (D700) Probable Cause: panic occurred SNMP Trap:
hpevtHp-uxCrashdumpStarted - 5823 in HPIFPTRAP.MIB.
Warning
5823
OS legacy PA hex fault code (Bxxx) Probable Cause: fault/panic SNMP Trap:
hpevtHp-uxHexFaultCode - 5824 in HPIFPTRAP.MIB.
Error
5824
OS dump status (EFxx) Probable Cause: panic, mca, or INIT path: attempt to write
out the dump is complete Recommended Action: No action required SNMP Trap:
hpevtHp-uxDumpStatus - 5825 in HPIFPTRAP.MIB.
Warning
5825
Setting processor response timeout failed Probable Cause: A PAL call made by SFW
has failed. Recommended Action: Reboot if necessary, if problem persists contact
your HP representative for support. SNMP Trap: hpevtSettingProcTimeoutFail - 5827
in HPIFPTRAP.MIB.
Warning
5827
Platform Agent Events
37