Table12: WWN Bezel LED Patterns continued, Power is OK.
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
Table12: WWN Bezel LED Patterns (continued) LED location and purpose LED Color Status Recommended Action NOTE: Check the individual port card (see Figure 15 on page 81) or CP card status LEDs (see Figure 16 on page 85) on the port side of the chassis to confirm the LED patterns. Power supply/ Power/Status Steady green Power is OK. No action required. Steady amber Power supply is faulty. Ensure that the correct AC power switch is on and the power supply is seated. If LED remains on, replace the power supply. Slow-flashing FRU header (SEEPROM cannot Replace power supply. amber be read) due to I2C problem. Fast-flashing amber Power supply is about to fail due Replace power supply. to failing fan inside the power supply. No light (LED is off) No power supply present or is not inserted or seated properly, or power source is unavailable. Insert power supply module, ensure it is seated properly, or check AC switch and power source. NOTE: Check the individual power supply LEDs on the port side of the chassis to confirm the LED patterns (see Figure 17 on page 72). NOTE: If a port card slot or power supply bay has a filler panel installed, the corresponding LEDs on the WWN card do not light up. Fabric OS 4.4.0f release notes 35