HP StorageWorks 2/16V HP StorageWorks Fabric OS 4.4.0F Release Notes (AA-RW89A - Page 44
Closed issues from Fabric OS 4.4.0e, Fixed
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Closed issues from Fabric OS 4.4.0e Table 9 lists issues resolved with the release of Fabric OS version 4.4.0e. Table 9 Fabric OS 4.4.0e closed issues summary Closed defect Issue: Found memory leaks in Asynchronous Response Router (ARR) and Management Server Daemon (MSD). Issue: Fabric Watch no longer reports contribution ports for port fault marginal condition in FOS 4.4.0. Status Fixed Fixed Symptom: 005/03/29-18:16:33, [FW-1437], 157,, WARNING, brocade2, Switch status change contributing factor Faulty ports: 1 faulty ports. Issue: fspfd experiences ASSERT while processing Link State Update record (LSU) during fabric merge. Fixed Symptom: The fspfd experienced an ASSERT while processing the LSU. The fabric is in interop mode; the lsr is generated by domain 4; and domain 5 is connected to domain 4 through port 1. The supportshow contains the fabricshow, and domains 4 and 5 are not present. Issue: Switch reboot with Time Service Daemon (tsd) panic while setting hardware clock due to I2C contention with another process. Fixed. Symptom: tsd panic in hardware clock set code. When contention occurs, the process blocked from I2C access could go beyond the time limit set by the software watchdog. The process is then killed by the software watchdog. 44 Closed issues from Fabric OS 4.4.0e