HP StorageWorks 2/16V HP StorageWorks Fabric OS 4.4.0F Release Notes (AA-RW89A - Page 46
Fixed., properly. Correct SNMP MIB
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
Table 9 Fabric OS 4.4.0e closed issues summary Closed defect Issue: Zone daemon (zoned) occasionally panics during zone changes. Status Fixed. Symptom: Switch panics with zoned when performing zoning changes and leaves behind a stack backtrace with cfgBufGetEnableSig as the top frame. Issue: With a 3rd party switch, when receiving an empty data record, the zone daemon (zoned) panics in interopmode. Fixed. Symptom: zoned assert in merge/zn_merge_dbg.c:452 Issue: Class3 frames could be dropped in session based zoning when a different port in the same zone goes off/on line. Fixed. Symptom: Customer's 3rd party box reports frame drop error. Issue: swFabricWatchTrap has Fixed #SUMMARY and #ARGUMENTS out of sync with OBJECTS order Solution: The new varbinding command swEventSeverityLevel was added in the varbind list but the argument list was not changed properly. Correct SNMP MIB to match the summary and argument list. 46 Closed issues from Fabric OS 4.4.0e