HP StorageWorks 2/16V HP StorageWorks Fabric OS 4.4.0F Release Notes (AA-RW89A - Page 37
Closed issues from Fabric OS 4.4.0c, Closed defect, Status
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Closed issues from Fabric OS 4.4.0c Table 7 lists issues resolved with the release of Fabric OS version 4.4.0c. Table 7 Fabric OS 4.4.0c closed issues summary Closed defect Status Issue: In switches running Fabric OS 4.x, the blade faults when it encounters BLOOM parity errors in the following SRAMs: R2T, TFR, STATS, SMI, FLT, PHAN Fixed Issue: In PID Format 2 configuration, host lost communication with device when another host reboot on a different port. For example: When port x is reset, traffic on port x +16 is lost. Fixed Issue: Path lost during storage virtualization device nodes reboot with SAN Switch 4/32 Fixed Example: At a high level, path loss during node reset on a storage virtualization device. The finisar trace and internal trace log identified multiple symptoms: • Many soft port faults due to the node not cutting off light during reboot. • PRLI dropped by switch due to duplicate SID cam entries • Route for a port was not set up correctly on the switch. Fabric OS 4.4.0f release notes 37