HP Visualize J5000 hp Visualize J5000, J7000 workstations service handbook (a4 - Page 101

Floppy Disk Drive Optional, Removing a Floppy Disk Drive, Replacing a Floppy Disk Drive,

Page 101 highlights

Field Replaceable Units (FRUs) FRU Removal and Replacement Floppy Disk Drive (Optional) This subsection describes how to remove and replace the optional floppy disk drive. NOTE The carrier assembly and drive bay may be used for either one DDS-3 tape drive, or one floppy disk drive. Removing a Floppy Disk Drive: 1. Remove the front panel bezel from the workstation. 2. Remove the two T-15 Torx screws securing the floppy disk drive to the front panel of the workstation chassis. 3. Slide the DDS-3 tape/floppy disk drive carrier assembly part way out of the chassis guide rails. Disconnect the the power and ribbon cables from the floppy disk drive. 4. Slide the carrier assembly the rest of the way out of the drive bay. 5. To remove the floppy disk drive from the carrier, remove the four T-10 Torx screws (two on each side) securing the floppy disk drive to the carrier. Replacing a Floppy Disk Drive: 1. Remove the front panel bezel and the top panel from the workstation.. 2. If you are installing a new floppy disk drive into the empty DDS-3 tape/floppy disk drive bay: a. Remove the two T-15 Torx screws securing the DDS-3 tape/floppy disk drive carrier to the front panel of the workstation. b. Slide the DDS-3 tape/floppy disk drive carrier out of the chassis guide rails. c. Remove the filler panels from the DDS-3 tape/floppy disk drive carrier as shown in Figure 4-9 on the next page. Figure 4-9. Removing the Filler Panels from the Carrier Chapter 4 97

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

Chapter 4
97
Field Replaceable Units (FRUs)
FRU Removal and Replacement
Floppy Disk Drive (Optional)
This subsection describes how to remove and replace the optional floppy disk drive.
NOTE
The carrier assembly and drive bay may be used for either one DDS-3 tape
drive, or one floppy disk drive.
Removing a Floppy Disk Drive:
1.
Remove the front panel bezel from the workstation.
2.
Remove the two T-15 Torx screws securing the floppy disk drive to the front panel of the
workstation chassis.
3.
Slide the DDS-3 tape/floppy disk drive carrier assembly part way out of the chassis
guide rails. Disconnect the the power and ribbon cables from the floppy disk drive.
4.
Slide the carrier assembly the rest of the way out of the drive bay.
5.
To remove the floppy disk drive from the carrier, remove the four T-10 Torx screws (two
on each side) securing the floppy disk drive to the carrier.
Replacing a Floppy Disk Drive:
1.
Remove the front panel bezel and the top panel from the workstation..
2.
If you are installing a new floppy disk drive into the empty DDS-3 tape/floppy disk drive
bay:
a.
Remove the two T-15 Torx screws securing the DDS-3 tape/floppy disk drive carrier
to the front panel of the workstation.
b.
Slide the DDS-3 tape/floppy disk drive carrier out of the chassis guide rails.
c.
Remove the filler panels from the DDS-3 tape/floppy disk drive carrier as shown in
Figure 4-9 on the next page.
Figure 4-9. Removing the Filler Panels from the Carrier