Troubleshooting Identifying LCD-Indicated Conditions Table 3-1. Chassis Codes for J5000 and J7000 Workstations Ostat Code FLT 7890 FRU DIMM Message MBE overwrt SBE FLT 7891 DIMM dup entry in PDT FLT 7892 SYS BD PDT write error FLT 7893 SYS BD PDT is full FLT 7900 SYS BD no DMT entry FLT 7901 SYS BD no rank entry FLT 7902 SYS BD bad refrsh intvl FLT 7903 SYS BD mem intrlv fail FLT 7904 SYS BD mem reloc failed FLT 7905 SYS BD mem intrlv error FLT 79FF SYS BD mem firmware err WRN 80F3 SYS BD err rd IODC byte WRN 80F4 EXT IO boot read error WRN 80F5 EXT IO boot exec error WRN 80F6 EXT IO boot read error WRN 80F7 EXT IO boot IO error WRN 80F8 EXT IO invalid boot dev WRN 80FC EXT IO invalid boot dev INI 8800 IOCARD PCI BusWlk start INI 88r1 IOCARD PCI Rope r walk INI 8802 IOCARD PCI BusWalk done INI 8803 SYS BD PCI alloc done INI 8804 SYS BD PCI config done Description Firmware replaced a correctable memory error entry in the PDT with an uncorrectable memory error entry at the same address. The PDT already contains an entry at that address. Error adding the entry to the PDT. The PDT is full--cannot add new entry. Internal error--cannot find DIMM entry. Internal error--cannot find rank entry. Computed refresh interval is invalid. Cannot generate memory interleave. Cannot interleave with relocated range (3.75GB - 4.0GB). Undefined memory interleave failure. Internal error--never expected this to happen. Cannot read IODC from ROM or card. Cannot load IODC entry_init for boot device. Error initializing boot device. Cannot load IODC entry_io for boot device. Error detected during boot device I/O. Invalid boot device class; bad IODC? Unexpected error; bad IODC? Starting PCI bus and device discovery. Starting PCI bus and device discovery on Rope r. PCI bus and device discovery complete. Done allocating address space for PCI devices. Done configuring PCI devices. Chapter 3 65

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

Chapter 3
65
Troubleshooting
Identifying LCD-Indicated Conditions
FLT
7890
DIMM
MBE overwrt SBE
Firmware replaced a correctable memory
error entry in the PDT with an
uncorrectable memory error entry at the
same address.
FLT
7891
DIMM
dup entry in PDT
The PDT already contains an entry at
that address.
FLT
7892
SYS BD
PDT write error
Error adding the entry to the PDT.
FLT
7893
SYS BD
PDT is full
The PDT is full--cannot add new entry.
FLT
7900
SYS BD
no DMT entry
Internal error--cannot find DIMM entry.
FLT
7901
SYS BD
no rank entry
Internal error--cannot find rank entry.
FLT
7902
SYS BD
bad refrsh intvl
Computed refresh interval is invalid.
FLT
7903
SYS BD
mem intrlv fail
Cannot generate memory interleave.
FLT
7904
SYS BD
mem reloc failed
Cannot interleave with relocated range
(3.75GB - 4.0GB).
FLT
7905
SYS BD
mem intrlv error
Undefined memory interleave failure.
FLT
79FF
SYS BD
mem firmware err
Internal error--never expected this to
happen.
WRN
80F3
SYS BD
err rd IODC byte
Cannot read IODC from ROM or card.
WRN
80F4
EXT IO
boot read error
Cannot load IODC entry_init for boot
device.
WRN
80F5
EXT IO
boot exec error
Error initializing boot device.
WRN
80F6
EXT IO
boot read error
Cannot load IODC entry_io for boot
device.
WRN
80F7
EXT IO
boot IO error
Error detected during boot device I/O.
WRN
80F8
EXT IO
invalid boot dev
Invalid boot device class; bad IODC?
WRN
80FC
EXT IO
invalid boot dev
Unexpected error; bad IODC?
INI
8800
IOCARD
PCI BusWlk start
Starting PCI bus and device discovery.
INI
88
r
1
IOCARD
PCI Rope
r
walk
Starting PCI bus and device discovery on
Rope
r
.
INI
8802
IOCARD
PCI BusWalk done
PCI bus and device discovery complete.
INI
8803
SYS BD
PCI alloc done
Done allocating address space for PCI
devices.
INI
8804
SYS BD
PCI config done
Done configuring PCI devices.
Table 3-1. Chassis Codes for J5000 and J7000 Workstations
Ostat
Code
FRU
Message
Description