Honeywell HNVE1 Reference Guide - Page 72
Board Setup View, Table 5-7, PTZ Configuration Settings, Protocol, Baud Rate, Stop Bit
View all Honeywell HNVE1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
Encoder and Device Configuration Figure 5-10 Board Setup View 1. Select the Board Setup tab. 2. Select from six PTZ dome protocols preconfigured for the dome you have connected to the encoder. Each PTZ dome has specific baud rate, stop bit, and parity settings. • Baud Rate settings range from 2400 to 115200. • Stop Bits settings range from 1 to 2. • Parity Bits settings range from None, Odd, Even. Note For the PTZ dome and the HNVE1 to be able to communicate, the PTZ switch settings on the PTZ dome and the HNVE1 encoder must be the same. See Configuring a PTZ Dome on page 62 for more information about PTZ switches. The encoder provides the option of six protocols. The preconfigured values of the baud rate, stop bit, and parity for each protocol are listed in this table: Table 5-7 PTZ Configuration Settings Protocol Pelco P Pelco D Diamond IntelliBusTM VCL MAXPRO-Net Baud Rate 4800 2400 9600 38400 9600 9600 Stop Bit 1 1 1 2 2 2 Parity None None Even None None Even 72