IBM 8479 Hardware Maintenance Manual

IBM 8479 - Eserver xSeries 200 Manual

IBM 8479 manual content summary:

  • IBM 8479 | Hardware Maintenance Manual - Page 1
    xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 2
  • IBM 8479 | Hardware Maintenance Manual - Page 3
    xSeries 200 Type 8479 and xSeries 200VL Type 8481 Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 4
    Note Before using this information and the product it supports, read "Notices" on page 137. Third Edition ( time. This publication was developed for products and services offered in the United States of America. IBM may not offer the products, services, or features discussed in this document in other
  • IBM 8479 | Hardware Maintenance Manual - Page 5
    , service information, error codes, error messages, and configuration information for the IBM® xSeries 200™ Type 8479 server and xSeries 200VL Type 8481 server. Eserver Important: This manual is intended for trained servicers who are familiar with IBM PC Server products. Before servicing an IBM
  • IBM 8479 | Hardware Maintenance Manual - Page 6
    y peligro ante de llevar a cabo cualquier operación. Online support Use the World Wide Web (WWW) to download Diagnostic, BIOS Flash, Device Driver files and documents. The Web address is: http://www.ibm.com/pc/support iv xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 7
    used in this book . . . . . 5 Reliability, availability, and serviceability . . . . . 5 Server controls and indicators 7 Turning on the server 8 Turning off the server 8 Diagnostics 9 Diagnostic tools overview 9 POST 9 POST beep code descriptions 9 POST error messages 9 Small computer system
  • IBM 8479 | Hardware Maintenance Manual - Page 8
    87 Symptom-to-FRU index 89 Beep symptoms 89 No beep symptoms 90 Diagnostic error codes 90 Error symptoms 92 POST error messages 95 ServeRAID 97 Undetermined problems 97 Parts listing 99 System 100 Keyboards 101 Power cords 102 Related service information . . . . . 103 Safety information
  • IBM 8479 | Hardware Maintenance Manual - Page 9
    programs are stored on the IBM Enhanced Diagnostics CD. These programs code displayed. 3. If the computer hangs with a POST error, go to the "Symptom-to-FRU index" on page 89. 4. If the computer hangs and no error is displayed, go to "Undetermined problems" on page 97. 5. Power supply problems
  • IBM 8479 | Hardware Maintenance Manual - Page 10
    " on page 10. v Check for the following responses: a. One beep. b. Readable instructions or the Main Menu. 3. DID YOU RECEIVE BOTH OF THE CORRECT RESPONSES suspect a problem, see "Undetermined problems" on page 97. 2 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 11
    General information The IBM xSeries 200 server delivers performance and affordability for general server applications. It is ideally suited for networking environments that require superior microprocessor performance, efficient memory management, flexibility, and large amounts of reliable data
  • IBM 8479 | Hardware Maintenance Manual - Page 12
    error code correction (ECC) support for up to three industry-standard PC133, 3.3 V, 168-pin, 133 megahertz (MHz), unregistered, synchronous dynamic random access memory (SDRAM) dual in-line memory modules (DIMMs). 4 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 13
    LAN). These controllers support Alert on LAN 2 technology. v IBM ServerGuide™ CDs programs and device drivers. In addition, the problem situations. v Attention: These notices indicate possible damage to programs, devices, or data. An attention notice is placed just before the instruction
  • IBM 8479 | Hardware Maintenance Manual - Page 14
    - Wake on LAN capability v Serviceability features - Adaptec 29160 built-in self-test (BIST) - Alert on LAN 2 - CD-ROM-based diagnostics - Diagnostic support of Ethernet adapters - Error codes and messages - Processor serial number access - Read-only memory (ROM) checksums - Vital product data
  • IBM 8479 | Hardware Maintenance Manual - Page 15
    disk drive is in use. Power-on light: This status indicator lights when you turn on the server. Power-control button: Press this button to manually turn the server on or off. See "I/O connector locations" on page 64 for the location of the input/output (I/O) connectors on the rear of the
  • IBM 8479 | Hardware Maintenance Manual - Page 16
    of the server. This starts an orderly shutdown of the operating system, if this feature is supported by your operating system, and places the server in standby mode. Note: After turning off the system to stop running. 8 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 17
    of a problem. v One short beep indicates the successful completion of POST. v More than one beep indicates that POST detected a problem. For more information, see "Beep symptoms" on page 89". POST error messages The possible types of beep codes that your system might emit are: © Copyright IBM Corp
  • IBM 8479 | Hardware Maintenance Manual - Page 18
    a problem exists; they are not intended to be used to identify a failing part. Troubleshooting and servicing of complex problems that are indicated by error messages should be performed by trained service personnel. 10 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 19
    the suggested action instructions for the first error message that appears. The following sections contain the error codes that might appear the information. is the diagnostic message that indicates the reason for the problem. Text messages The diagnostic text message format is as follows: Function
  • IBM 8479 | Hardware Maintenance Manual - Page 20
    to download the latest image of the IBM Enhanced Diagnostics from the World Wide Web and create a startable Enhanced Diagnostics diskette: 1. Go to the following World Wide Web site: http://www.ibm.com/pc/support 12 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 21
    downloaded. IBM Enhanced Diagnostics CD in the CD-ROM drive. The diagnostics will load. Follow the instructions on the screen to run the diagnostics. When the tests have completed, you can view the Test Log by selecting Utility from the top of the screen. If the hardware checks out OK but the problem
  • IBM 8479 | Hardware Maintenance Manual - Page 22
    for troubleshooting power problems is BIOS flash diskette. v Download files from the World Wide Web to make a BIOS flash diskette. Go to http://www.ibm.com/pc/support/ select IBM System Support, and then make the selections for your system. Complete the following steps to recover the BIOS code
  • IBM 8479 | Hardware Maintenance Manual - Page 23
    Therefore, you must reconfigure the server after clearing CMOS memory (see "Configuration" on page 25). If possible, record 800-465-6666 within Canada. Outside the U.S. and Canada, call your IBM reseller or IBM marketing representative. Note: After you replace the battery, you must reconfigure your
  • IBM 8479 | Hardware Maintenance Manual - Page 24
    replacing the battery, use only IBM Part Number 33F8354 or an begin" on page 40, and follow any special handling and installation instructions supplied with the replacement battery. 2. Turn off the server and server. 16 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 25
    The processor housing cover covering the processor and memory area is removed for no longer that optional adapters are routed according to the instructions provided with the adapters (ensure that Troubleshooting the Ethernet controller This section provides troubleshooting information for problems
  • IBM 8479 | Hardware Maintenance Manual - Page 26
    supports auto-negotiation. If not, try configuring the integrated Ethernet controller manually problems that have definable symptoms. Table 3. Ethernet troubleshooting chart Ethernet controller problem Suggested Action The server stops running when loading device drivers. The PCI BIOS driver
  • IBM 8479 | Hardware Maintenance Manual - Page 27
    Ethernet troubleshooting chart (continued) Ethernet controller problem Suggested Ethernet controller. another adapter was v Make sure that your PCI server BIOS is current. added to the server. v Reseat the adapter. v driver, and suggested actions to resolve each problem. Table 4. NetWare driver
  • IBM 8479 | Hardware Maintenance Manual - Page 28
    the adapters to be bound. If the problem persists, contact your network supplier. Failed to create AFT group. Make sure that the drivers for supported adapters are loaded, primary adapter is bound the primary adapter. 20 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 29
    driver for the supported adapter supported by AFT. Action: Load and bind AFT only on supported problem persists, contact your network supplier. Please unload all LAN drivers driver messages for the Ethernet controller Error code (hex) 0x00 0x01 0x02 0x03 0x0D Description Explanation: The driver memory
  • IBM 8479 | Hardware Maintenance Manual - Page 30
    or Windows 2000) driver messages for the Ethernet controller (continued) Error code (hex) Description 0x0E Explanation: Could not allocate enough memory for receive queue. Action: 1. From the Windows NT desktop, select Start "Control Panel "Networks "Adapters. 2. Select your IBM Ethernet adapter
  • IBM 8479 | Hardware Maintenance Manual - Page 31
    Table 6. NDIS (Windows NT or Windows 2000) driver teaming messages for the Ethernet controller (continued) Event ID Type Description 03 Error Explanation: Unable to read required registry parameters. Action: Reconfigure the adapter team
  • IBM 8479 | Hardware Maintenance Manual - Page 32
    Table 6. NDIS (Windows NT or Windows 2000) driver teaming messages for the Ethernet controller (continued) Event ID Type Description 19 Informational same LAN segment. Reconfigure the team if necessary. 24 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 33
    Boot Agent Utility program is part of the BIOS code that comes with the server. Depending on startup order, to select operating-system wake-up support, and to set menu wait times. See tools specifically designed for IBM xSeries servers. You can section provides the instructions for starting the
  • IBM 8479 | Hardware Maintenance Manual - Page 34
    instructions set for the system and IBM system management adapters, or in the version of BIOS code installed on the server. issue date of the BIOS stored in the flash electronically erasable programmable read-only memory (EEPROM). v Devices 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 35
    service representative. - Memory Settings If a memory error is detected during POST or memory configuration, the server can automatically disable the failing memory bank and continue operating with reduced memory capacity. If this occurs, you must manually enable the memory bank after the problem
  • IBM 8479 | Hardware Maintenance Manual - Page 36
    SCSI IDs v Locate and correct configuration conflicts The following sections provide the instructions for starting the SCSISelect Utility program and descriptions of the menu choices that SCSI Select Utility program. 28 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 37
    to its default values, press the F6 key; then, follow the on-screen instructions. You can view or change the following controller settings: - Host Adapter SCSI ID options. These options include support for large hard disk drives and support for drives with UltraSCSI speeds. Configuration 29
  • IBM 8479 | Hardware Maintenance Manual - Page 38
    , follow the instructions on the screen. Note: Hard disk drives normally contain more tracks than their stated capacity (to allow for defective tracks). A message appears on the screen if the defect limit is reached. If this happens, replace the hard disk drive. 30 xSeries 200 Type 8479 and xSeries
  • IBM 8479 | Hardware Maintenance Manual - Page 39
    the setup prompt v Set menu wait time v Select operating-system wake-up support Attention: The network startup protocols and startup order options are not supported on this product. The following sections provide instructions for starting the PXE Boot Agent Utility program and descriptions of the
  • IBM 8479 | Hardware Maintenance Manual - Page 40
    selection to Enabled to use the Wake on LAN support. 3. When using a non-ACPI operating system Web site at http://www.ibm.com/pc/coupon. The ServerGuide BIOS update program, which updates the BIOS code directly from the CD v Device drivers 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 41
    supported IBM server with an enabled startable (bootable) CD-ROM drive. Not all features are supported code (firmware) level without creating diskettes. v Checks the system BIOS code and microcode (firmware) levels of supported options and provides updated device drivers for most adapters and devices
  • IBM 8479 | Hardware Maintenance Manual - Page 42
    settings, additional device drivers, and installation after the NOS is installed. See the documentation that comes with the adapter. 2. Diagnostics for the server come in BIOS code or on a separate diagnostics CD. 34 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 43
    specific utility programs such as service processor disk operating system (DOS) utilities, system diagnostics, flash BIOS updates, and other programs to create. The diskettes that you can create are the device-driver diskettes for the installed adapters or controllers. The ServerGuide program prompts
  • IBM 8479 | Hardware Maintenance Manual - Page 44
    to use the ServerGuide program to install the NOS, download the latest NOS installation instructions: 1. Go to http://www.ibm.com/pc/support. 2. Click Servers. 3. From the Family field, and view the online Overview. 36 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 45
    instructions to help install options to the server. For a list of supported options for the server, see the ServerProven® list at http://www.pc.ibm. retaining bracket Memory modules EMC shield Microprocessor Filler panel Drive cage Adapter support bracket Front door Support bracket assembly
  • IBM 8479 | Hardware Maintenance Manual - Page 46
    3 Battery PCI 4 PCI 5 SCSI LED (J3) System board internal cable connectors The following illustration identifies system board connectors for internal cables. 38 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 47
    the system, a jumper is installed on pins 2 and 3 of the boot block jumper. Note: The boot block jumper (JROM1) should only be removed by an IBM authorized service representative. CMOS jumper Installing options 39
  • IBM 8479 | Hardware Maintenance Manual - Page 48
    v Have a small, flat-blade screwdriver available. v For a list of supported options for the xSeries 200, refer to http:// www.ibm.com/pc/compat on the World Wide Web. Working inside the server with rear of the server. 40 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 49
    v Cables for optional adapters are routed according to the instructions that are provided with the adapters. v A failed hole on the bottom of the server and place the foot between the guides as indicated. Note: The following illustration shows the rear feet located on the bottom rear of
  • IBM 8479 | Hardware Maintenance Manual - Page 50
    Guides Feet (locked position) Guides 5. Rotate the foot outward until the foot locks into place. 6. Complete steps 2 through 5 for each foot. cover removal The following illustration shows how to remove the side cover. 42 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 51
    Note: The illustrations in this document might differ slightly from your hardware. Cover-release latch Key lock Complete the following steps to remove the side cover of the server: 1. Review the information in "Before you begin" on page 40. 2. Turn off the server and peripheral devices and
  • IBM 8479 | Hardware Maintenance Manual - Page 52
    the bezel up to release the two tabs at the bottom edge of the bezel. Store the bezel in a safe place. 44 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 53
    working with some options such as hard disk drives, microprocessors, and memory modules you must first remove the support bracket assembly to access the location of the option. Complete the following steps to remove the support bracket assembly: 1. Review the information in "Before you begin" on
  • IBM 8479 | Hardware Maintenance Manual - Page 54
    instructions that come with the adapter. v You can install full-length adapters in all five PCI expansion slots. v The server supports 5.0 V and universal PCI adapters; it does not support order, if you have not 46 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 55
    . See "Configuration" on page 25 for details on using the Configuration/Setup Utility program. v For a list of supported options for the server, refer to http://www.ibm.com/pc/ compat on the World Wide Web. Adapter installation Expansion slot cover Adapter retaining bracket Adapter Adapter
  • IBM 8479 | Hardware Maintenance Manual - Page 56
    upper corners, and align it with the expansion slot guides; then, press the adapter firmly into the PCI expansion have installed a full-length adapter, rotate the front adapter support bracket to the closed (locked) position. 14. Reinstall 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 57
    If you have another adapter to install or remove, do so now. 5. If you have installed a full-length adapter, rotate the front adapter support bracket to the closed (locked) position. 6. Reinstall the rear adapter retaining bracket; then, rotate the bracket to the closed (locked) position. 7. If you
  • IBM 8479 | Hardware Maintenance Manual - Page 58
    that comes with the option for the conversion kit installation instructions. Note: Only 3.5-in. options that ship with proper mounting hardware can be supported in the 5.25-in. bays. 6. If you have option. 50 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 59
    not replace it with another. 8. For a list of supported options for the server, refer to http://www.ibm.com/ pc/us/compat on the World Wide Web. Note: You can only install a 3.5-in. device in bay 4. 3. Check the instructions that come with the drive to see if you need to set any switches or jumpers
  • IBM 8479 | Hardware Maintenance Manual - Page 60
    on page 42 for details). 3. Remove the support bracket assembly and disconnect the fan cable from the connector (SYSFA1) result in exposure to hazardous laser radiation. There are no serviceable parts inside the device. v Use of controls or 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 61
    -bracket assembly and reconnect the fan cable to the connector (SYSFA1) on the system board. See "Removing the support bracket assembly" on page 45 for details. See "System board internal cable connectors" on page 38 for the location of the fan cable connector. 12.
  • IBM 8479 | Hardware Maintenance Manual - Page 62
    the drive. 7. Attach the blue plastic guide rails to the sides of the drive using the screws and guide rails provided in the drive cage. 8. in this section for memory connector locations.) v The xSeries 200 server supports 128 MB, 256 MB, and 512 MB DIMMs. The server supports a minimum of 128 MB
  • IBM 8479 | Hardware Maintenance Manual - Page 63
    the ServerProven list at http://www.ibm.com/pc/compat for a list of memory modules for use with the server. v Installing or removing see "Side cover removal" on page 42 for details). 3. Remove the support-bracket assembly and disconnect the fan cable from the connector (SYSFA1) on the system board.
  • IBM 8479 | Hardware Maintenance Manual - Page 64
    BIOS code. The latest level of the BIOS for the server is available through the World Wide Web; see http://www.ibm.com/support/. 2. For a list of supported operating systems, see http://www.ibm. your server model. 56 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 65
    Note: The following illustration shows a heat sink installed on the microprocessor. Microprocessor connector Microprocessor Heat sink Retainer Lever Tab Microprocessor orientation indicator Installing options 57
  • IBM 8479 | Hardware Maintenance Manual - Page 66
    (see "Side cover removal" on page 42 for details). 3. Remove the support-bracket assembly and disconnect the fan cable from the connector (SYSFA1) on the system board. See " sink and lift it off the microprocessor. 58 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 67
    the fan cable from the connector (SYSFA1) on the system board. See "Removing the support bracket assembly" on page 45 and "System board internal cable connectors" on page 38 for instructions. 4. Install the microprocessor: a. Touch the static-protective package containing the new microprocessor to
  • IBM 8479 | Hardware Maintenance Manual - Page 68
    the fan cable to the connector (SYSFA1) on the system board. See "Removing the support bracket assembly" on page 45 for details. See "System board internal cable connectors" on on the peripheral devices and the server. 60 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 69
    Installing a security U-bolt To help prevent hardware theft, you can add a security U-bolt and cable to the server. After you add the security cable, make sure that it does not interfere with other cables that are connected to the server. Before you begin: v Obtain the following items: - A flat-
  • IBM 8479 | Hardware Maintenance Manual - Page 70
    and, for certain options, run the Configuration/Setup Utility program. Follow the instructions in this section. Note: If you have just plugged the power cords might differ slightly from your hardware. 2. If you removed the support-bracket assembly after you removed the cover, reinstall it before you
  • IBM 8479 | Hardware Maintenance Manual - Page 71
    latch. 3. Lock the cover. 4. If you have not done so already, make sure the stabilizing feet are in the stabilizing position so that they properly support the server. See "Stabilizing feet" on page 41 for details. 5. Reconnect the external cables and power cords to the server, and then plug the
  • IBM 8479 | Hardware Maintenance Manual - Page 72
    information about installing any required device drivers. If the server has a all peripheral devices are turned off. 3. Follow the instructions that come with the option to prepare it for installation the server cables and connector panel have color-coded connectors, match the color of the cable end
  • IBM 8479 | Hardware Maintenance Manual - Page 73
    and PCI extender board options connectors" on page 37 for the location of the PCI slots. If the server cables and connector panel have color-coded connectors, match the color of the cable end with the color of the connector. For example, match a blue cable end with a blue panel connector, a red
  • IBM 8479 | Hardware Maintenance Manual - Page 74
    connector The system board has one mouse connector that supports a mouse or other pointing device. The mouse 1 I/O Data 2 N/A Reserved 3 N/A Ground 4 N/A +5 V dc 5 I/O Keyboard clock 6 N/A Reserved 66 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 75
    parallel connector as bidirectional that is, so that data can be both read from and written to a device. In bidirectional mode, the server supports the ECP and EPP modes. Complete the following steps to view or change the parallel-connector assignment: 1. Restart the server and watch the monitor
  • IBM 8479 | Hardware Maintenance Manual - Page 76
    " on page 64 for the location of these connectors. The following table shows the pin-number assignments for the serial connectors. 1 5 6 9 68 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 77
    to enable your operating system to address the Ethernet controller. The device drivers are provided on the ServerGuide CDs. High performance Ethernet modes Your Ethernet controller supports optional modes, such as teaming, priority packets, and virtual LANs, which provide higher performance and
  • IBM 8479 | Hardware Maintenance Manual - Page 78
    and routing 802.1p tagged packets must support 802.1p. v The adapters on these devices must support 802.1p. The Ethernet controller in your xSeries 200 and all IBM 10/100 Ethernet Security Adapters support 802.1p. 70 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 79
    , or Novell NetWare 4.1x or later. Notes: 1. Windows NT versions prior to 4.0 do not support VLANs. 2. VLANs require NT 4.0 with Service Pack 3.0 and the network driver interface specification (NDIS) driver hotfix from Microsoft. 3. In Windows NT, VLANs cannot be implemented on controllers that have
  • IBM 8479 | Hardware Maintenance Manual - Page 80
    . 3. Some operating systems do not support USB devices. Refer to your operating-system documentation to determine whether your operating system supports USB devices. USB cables and hubs You page 64 for the location 72 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 81
    of the USB connectors. The following table shows the pin-number assignments for the USB connectors. 1 4 Table 12. USB connector pin-number assignments Pin Signal 1 +5 V 2 -Data 3 +Data 4 Ground Audio connectors The audio connectors are used to connect external audio equipment to the
  • IBM 8479 | Hardware Maintenance Manual - Page 82
    SCSI adapter, which supports a single Ultra160 SCSI channel in a full-featured PCI 2.1-/2.2-compliant bus master package. This configuration supports a zero wait state, 32-bit memory transfers at 160 model. If you 74 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 83
    correct cables for use with external devices, contact your IBM reseller or IBM marketing representative. For information about the maximum length of PCI adapter. Refer to the information that is provided with the device for instructions to set its SCSI ID. If a SCSI adapter is installed in the
  • IBM 8479 | Hardware Maintenance Manual - Page 84
    /Output 31 +Data 8 65 -Data 8 32 +Data 9 66 -Data9 33 +Data 10 67 -Data 10 34 +Data 11 68 -Data 11 76 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 85
    (FRUs) should be replaced by qualified service personnel only. Hard disk drive cage see "Side cover removal" on page 42). 5. Remove the support bracket (see "Removing the support bracket assembly" on page 45). 6. Remove any hard disk memory when you remove the cage. © Copyright IBM Corp. 2001 77
  • IBM 8479 | Hardware Maintenance Manual - Page 86
    the rear of the server. 6. Gently move the power supply away from the chassis and lift it out of the server. 78 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 87
    " on page 42). 4. Remove the support bracket (see "Removing the support bracket assembly" on page 45). 5. Remove position at the rear of the server. 9. Guide the rubber extensions through the apertures. 10. Use side before performing this service procedure. Rotate the feet in toward the
  • IBM 8479 | Hardware Maintenance Manual - Page 88
    the support bracket assembly" on page 45). 6. Disconnect the cables. 7. Remove the adapter cards and both adapter retaining brackets (see "Adapter installation" on page 47). 8. Remove the hard disk drive cage (see "Hard disk drive cage" on page 77). 9. Remove memory modules (see "Memory modules
  • IBM 8479 | Hardware Maintenance Manual - Page 89
    screws from the floppy disk drive cage. 6. Gently slide the floppy disk drive toward the front of the server and lift it out. FRU information (service only) 81
  • IBM 8479 | Hardware Maintenance Manual - Page 90
    the aperture. 8. Gently pinch together the upper release latches and slide the latches through the aperture and remove the button kit. 82 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 91
    bracket (see "Removing the support bracket assembly" on page 45). 6. Remove all adapter cards. 7. Unplug the speaker from the system board. 8. Gently push the two tabs of the adapter guide assembly inward until the assembly is released; lift it up and out of the server. 9. Slide the speaker up
  • IBM 8479 | Hardware Maintenance Manual - Page 92
    . 8. From the underside, grasp the bezel release latch in the center and gently pull it back and away from the server. 84 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 93
    a safe place. 7. Using a screwdriver, gently pry the cover away from the server in the rear and slide the unit away from the server. FRU information (service only) 85
  • IBM 8479 | Hardware Maintenance Manual - Page 94
    -off the server, if it is on. 2. Unplug the server. 3. Firmly grasp the handle support and slide it away from the front bezel. 4. Lift up on the handle support to remove it from the slots in the top of the chassis. 86 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 95
    the adapter retainer to the open position. 6. Grasp the adapter retainer and gently slide the top and bottom tabs out of the notches. FRU information (service only) 87
  • IBM 8479 | Hardware Maintenance Manual - Page 96
    88 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 97
    in Setup to be stored in CMOS. 3. For IBM devices not supported by index, refer to the manual for that device. 4. Always start with "General checkout have available when servicing the computer. The POST BIOS displays POST error codes and messages on the screen. Beep symptoms Beep symptoms are short
  • IBM 8479 | Hardware Maintenance Manual - Page 98
    POST No ac power No beep and no video FRU/Action 1. Check speaker cables 2. Speaker 3. System board 1. Check speaker connections 2. Speaker 3. System board 1. Check the power cord. 2. Power supply. 1. See "Undetermined problems" on page 97 Diagnostic error codes Note: In the following error
  • IBM 8479 | Hardware Maintenance Manual - Page 99
    Error Code/Symptom extended configuration status and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable 3. Adapter 075-XXX- 201-XXX-0NN (Failed Memory test, see ″Memory Settings″ on page 27.) NN = DIMM location. 1. DIMM Location J1-J4 2. Memory card 201-XXX-999 (
  • IBM 8479 | Hardware Maintenance Manual - Page 100
    Error Code/Symptom FRU/Action 206-XXX-000 disk number refers to the RAID logical array. 1. Fixed Disk 2 217-XXX-002 (Failed BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the 92 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 101
    IBM monitors have 2. Run Video Diagnostics. If diagnostics pass, the problem may be a video driver. their own self-tests. If you 3. Display Adapter / System Board suspect a problem with the monitor, refer to the information that comes with the monitor for adjusting and testing instructions
  • IBM 8479 | Hardware Maintenance Manual - Page 102
    -USB) keyboard is attached to the keyboard port, then the USB is disabled and no USB device will work during POST. 2. The correct USB device driver is installed. 3. Your operating system supports USB devices. 94 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 103
    is supported by ServerGuide. See theSetup and NOS CD. Installation CD label for a list of NOS versions supported. BIOS ROM checksum error -- system halted (BIOS code checksum in BIOS chip incorrect; BIOS may be corrupt) 1. Replace BIOS ESC to skip memory 1. Full memory test may be skipped by pressing
  • IBM 8479 | Hardware Maintenance Manual - Page 104
    detected an error during memory testing) 1. Note additional information about specific error that appears on the screen 2. DIMM Override enabled -- Defaults 1. Run Configuration/Setup loaded (system cannot boot using current CMOS 2. Battery configuration; BIOS has 3. System board overridden
  • IBM 8479 | Hardware Maintenance Manual - Page 105
    codes and procedures, refer to the Hardware Maintenance Manual for the particular RAID adapter in the system being serviced. Undetermined problems Any external devices v Modem, printer, mouse, or non-IBM devices v Each adapter v Drives v Memory Modules (Minimum requirement = one 128 MB DIMM) Note:
  • IBM 8479 | Hardware Maintenance Manual - Page 106
    98 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 107
    Parts listing © Copyright IBM Corp. 2001 25 26 24 23 22 21 31 29 30 27 28 1 32 2 3 4 5 67 8 9 10 20 19 18 17 16 14 13 12 11 15 99
  • IBM 8479 | Hardware Maintenance Manual - Page 108
    System This parts listing supports: Type 8479 models 10X, 11X, 13X, 3AX, 31X, 40X, 41X, 42X, 50X, 51X, 52X, 60X, 61X, 62X; and Type 8481 model 31X. Index 1 1 2 3 4 5 5 5 6 7 7 8 9 10 11 12 13 14 15 16 17 18 19 19 20 20 21 22 22 23 24 24
  • IBM 8479 | Hardware Maintenance Manual - Page 109
    (1); isolator support (4); key service label (all models) SCSI U160 adapter (all models) ATI video card (all models) Bezel kit (all models) Door, bezel (all models) Cable, SCSI 5-drop (models 10X, 13X, 40X, 42X, 52X, 60X, 62X) Cable, IDE 2-drop (models 10X, 11X, 21X, 31X, 40X, 41X, 50X, 51X, 60X, 61X
  • IBM 8479 | Hardware Maintenance Manual - Page 110
    America FRU No. 01K9851 01K9853 12J5120 12J5122 12J5124 12J5126 12J5128 12J5987 55H6643 55H6646 76H4865 6952301 (110) 1838574 (220) 36L8886 (220V/15A) 102 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 111
    are designed to help you isolate problems. They are written with the assumption that you have model-specific training on all computers, or that are familiar with the computers, functions, terminology, and service information provided in this manual. Safety information The following section contains
  • IBM 8479 | Hardware Maintenance Manual - Page 112
    and modems before you open the server covers, unless instructed otherwise in the installation and configuration procedures. Observe the the special safety precautions when you work with very high voltages; these instructions are in the safety sections of maintenance information. Use extreme care
  • IBM 8479 | Hardware Maintenance Manual - Page 113
    users and service personnel from injury. This guide addresses only -IBM features or options not covered by this inspection guide. If any unsafe conditions are present, you must determine how serious the apparent hazard could be and whether you can continue without first correcting the problem
  • IBM 8479 | Hardware Maintenance Manual - Page 114
    Check for any obvious non-IBM alterations. Use good judgment as to the safety of any non-IBM alterations. 6. Check inside listed below, to provide protection that meets the specific service requirement. Note: The use of a grounding system 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 115
    Important: All caution and danger statements in this IBM documentation begin with a number. This number is and danger statements before performing any of the instructions. v Statement 1 DANGER Electrical current from power open the device covers, unless instructed otherwise in the installation and
  • IBM 8479 | Hardware Maintenance Manual - Page 116
    . CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by in exposure to hazardous laser radiation. There are no serviceable parts inside the device. v Use of controls or 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 117
    the power source. 2 1 v Statement 10 CAUTION: Do not place any object weighing more than 82 kg (180 lbs.) on top of rack-mounted devices. Related service information 109
  • IBM 8479 | Hardware Maintenance Manual - Page 118
    Importante: Todas as instruções de cuidado e perigo da IBM documentation começam com um número. Este número é utilizado para fazer referê os cabos de sinal dos conectores. 4. Remova todos os cabos dos dispositivos. 110 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 119
    (011) 889-8986, para obter informações sobre como enviar a bateria pelo correio para a IBM. Instrução 3 PRECAUCIÓN: Quando produtos a laser (unidades de CD-ROM, unidades de DVD, dispositivos nu ou com instrumentos íticos, e evite exposição direta ao raio. Instrução 4 Related service information 111
  • IBM 8479 | Hardware Maintenance Manual - Page 120
    elétrica. 2 1 CUIDADO: Instrução 10 CUIDADO: Não coloque nenhum objeto com peso superior a 82 kg (180 lbs.) sobre dispositivos montados em rack. 112 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 121
    Related service information 113
  • IBM 8479 | Hardware Maintenance Manual - Page 122
    114 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 123
    Related service information 115
  • IBM 8479 | Hardware Maintenance Manual - Page 124
    116 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 125
    Related service information 117
  • IBM 8479 | Hardware Maintenance Manual - Page 126
    118 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 127
    Related service information 119
  • IBM 8479 | Hardware Maintenance Manual - Page 128
    120 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 129
    indiquées dans la bibliothèque IBM documentation sont précédées d'un num réseaux, aux systèmes de télécommunication et aux modems (sauf instruction contraire mentionnée dans les procédures d'installation et de configuration). v Débranchez tous les câbles des unités. Related service information 121
  • IBM 8479 | Hardware Maintenance Manual - Page 130
    au lithium usagée par une pile de référence identique exclusivement - voir la référence IBM - ou par une pile équivalente recommandée par le fabricant. Si votre système une exposition directe au rayon. Notice n° 4 122 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 131
    de prise de courant. 2 1 Notice n° 10 ATTENTION: Ne posez pas d'objet dont le poids dépasse 82 kg sur les unités montées en armoire. Related service information 123
  • IBM 8479 | Hardware Maintenance Manual - Page 132
    Wichtig: Alle Sicherheitshinweise in dieser IBM documentation beginnen mit einer Nummer. Diese Nummer verweist auf einen englischen en. 4. Netzstecker an Steckdose anschließen. 5. Gerät einschalten. Hinweis 2 124 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 133
    ACHTUNG: Eine verbrauchte Batterie nur durch eine Batterie mit der IBM Teilenummer 33F8354 oder durch eine vom Hersteller empfohlene Batterie ersetzen. Wenn Ihr sehen, nicht direkt mit optischen Instrumenten betrachten und den Strahlungsbereich meiden. Hinweis 4 Related service information 125
  • IBM 8479 | Hardware Maintenance Manual - Page 134
    aus den Netzsteckdosen herausgezogen wurden. 2 1 Hinweis 10 ACHTUNG: Keine Gegenstände, die mehr als 82 kg wiegen, auf Rack-Einheiten ablegen. 126 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 135
    Tutti gli avvisi di attenzione e di pericolo riportati nella pubblicazione IBM documentation iniziano con un numero. Questo numero viene utilizzato per confrontare . 3. Rimuovere i cavi di segnale dai connettori. 4. Rimuovere tutti i cavi dalle unità. Avviso 2 Related service information 127
  • IBM 8479 | Hardware Maintenance Manual - Page 136
    ATTENZIONE: Quando si sostituisce la batteria al litio, utilizzare solo una batteria IBM con numero parte 33F8354 o batterie dello stesso tipo o di tipo equivalente ed evitare l'esposizione diretta al fascio. Avviso 4 128 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 137
    dalla sorgente di alimentazione. 2 1 Avviso 10 ATTENZIONE: Non poggiare oggetti che pesano più di 82 kg sulla parte superiore delle unità montate in rack. Related service information 129
  • IBM 8479 | Hardware Maintenance Manual - Page 138
    130 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 139
    Related service information 131
  • IBM 8479 | Hardware Maintenance Manual - Page 140
    132 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 141
    Importante: Todas las declaraciones de precauciín de esta IBM documentation empiezan con un número. Dicho número se emplea para establecer una referencia cruzada de una declaraci Retire los cables de señal de los conectores. 4. Retire los cables de los dispositivos. Related service information 133
  • IBM 8479 | Hardware Maintenance Manual - Page 142
    sustituir la batería de litio, utilice únicamente el número de pieza 33F8354 de IBM o cualquier tipo de batería equivalente que recomiende el fabricante. Si el sistema tiene exposiciín directa al rayo. Declaración 4 134 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 143
    fuente de alimentaciín. 2 1 Declaración 10 PRECAUCIÓN: No coloque ningún objeto que pese más de 82 kg (180 libras) encima de los dispositivos montados en bastidor. Related service information 135
  • IBM 8479 | Hardware Maintenance Manual - Page 144
    this survey, complete it, and then fax it to IBM HMM Survey at 919-543-8167 (USA). Name Phone number 1. Do you like this manual? h Yes h No 2. What would you like to see added, changed, or deleted in this manual 3. What is your service experience level? h Less than five years h More than five
  • IBM 8479 | Hardware Maintenance Manual - Page 145
    problem determination. If possible, have this information available when requesting assistance from Service Support BIOS IBM operates. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Subject to IBM
  • IBM 8479 | Hardware Maintenance Manual - Page 146
    on operating environments. IBM makes no warranties, express or implied, regarding non-IBM products and services that are ServerProven, product, and service names may be trademarks or service marks of others. 138 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
  • IBM 8479 | Hardware Maintenance Manual - Page 147
  • IBM 8479 | Hardware Maintenance Manual - Page 148
    Part Number: 24P2927 (1P) P/N: 24P2927
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

xSeries
200
Type
8479
and
xSeries
200VL
Type
8481
Hardware
Maintenance
Manual
±²³