IBM 8479 Hardware Maintenance Manual - Page 100
Error, symptoms
UPC - 087944653912
View all IBM 8479 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 100 highlights
Error Code/Symptom FRU/Action 206-XXX-000 (Failed Diskette Drive test) 1. Cable 2. Diskette Drive 3. System Board 215-XXX-000 (Failed IDE CD-ROM test) 1. CD-ROM Drive Cables 2. CD-ROM Drive 3. System Board 217-198-XXX (Could not establish drive parameters) 1. Check cable and termination 2. SCSI backplane 3. Fixed disk 217-XXX-000 (Failed BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 1. Fixed Disk 1 217-XXX-001 (Failed BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 1. Fixed Disk 2 217-XXX-002 (Failed BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 1. Fixed Disk 3 301-XXX-000 (Failed Keyboard test) 1. Keyboard 302-XXX-000 (Mouse failed) 1. Mouse 305-XXX-000 (Video monitor failure) 1. Video Monitor 2. Video Adapter 405-XXX-000 (Failed Ethernet test on controller on the System Board) 1. Verify that Ethernet is not disabled in BIOS. 2. System Board 405-XXX-00N (Failed Ethernet test on adapter in PCI slot N) 1. Adapter in PCI slot N. 2. System Board 415-XXX-000 (Failed Modem test) 1. Cable 2. Modem 3. System Board Error symptoms General FRU/Action CD is not working properly. 1. Clean the CD. 2. Run CD-ROM diagnostics. 3. CD-ROM Drive 92 xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual