IBM 8479 Hardware Maintenance Manual - Page 99
Microprocessor
UPC - 087944653912
View all IBM 8479 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
Error Code/Symptom FRU/Action 015-XXX-015 (Failed USB External Loopback test) 1. Make sure parallel port is not disabled 2. Re-run USB External Loopback test 3. System Board 015-XXX-198 (USB device connected during USB test) 1. Remove USB devices from USB1 and USB2 2. Re-run test 3. System Board 020-XXX-000 (Failed PCI Interface test) 1. System Board 030-XXX-000 1. System Board (Failed Internal SCSI interface test) 030-XXX-00N (Failed SCSI test on PCI slot N. Check system error log before replacing a FRU.) 1. Adapter in Slot N 035-XXX-099 1. No adapters were found. 2. If adapter is installed re-check connection. 035-XXX-S99 (Failed RAID test on PCI slot S. S = number of failing PCI slot. Check System Error Log before replacing a FRU.) 1. Adapter 2. SCSI Backplane 3. Cable 035-XXX-SNN (Check System Error Log 1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S. before replacing a FRU. S = number of failing PCI slot; NN = SCSI ID of failing fixed disk.) 035-253-S99 (RAID adapter initialization failure) 1. ServeRAID Adapter in slot S is not configured properly. Obtain the basic and extended configuration status and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable 3. Adapter 075-XXX-000 (Failed Power Supply test) 1. Power Supply 089-XXX-001 1. Microprocessor (Failed Microprocessor test) 180-XXX-003 (Failed System Board LED test) 1. System Board 201-XXX-0NN (Failed Memory test, see ″Memory Settings″ on page 27.) NN = DIMM location. 1. DIMM Location J1-J4 2. Memory card 201-XXX-999 (Multiple DIMM failure, see error text.) 1. See error text for failing DIMMs 202-XXX-001 (Failed System Cache test) 1. Microprocessor CPU 1 Symptom-to-FRU index 91