IBM 8479 Hardware Maintenance Manual - Page 99

Microprocessor

Page 99 highlights

Error Code/Symptom FRU/Action 015-XXX-015 (Failed USB External Loopback test) 1. Make sure parallel port is not disabled 2. Re-run USB External Loopback test 3. System Board 015-XXX-198 (USB device connected during USB test) 1. Remove USB devices from USB1 and USB2 2. Re-run test 3. System Board 020-XXX-000 (Failed PCI Interface test) 1. System Board 030-XXX-000 1. System Board (Failed Internal SCSI interface test) 030-XXX-00N (Failed SCSI test on PCI slot N. Check system error log before replacing a FRU.) 1. Adapter in Slot N 035-XXX-099 1. No adapters were found. 2. If adapter is installed re-check connection. 035-XXX-S99 (Failed RAID test on PCI slot S. S = number of failing PCI slot. Check System Error Log before replacing a FRU.) 1. Adapter 2. SCSI Backplane 3. Cable 035-XXX-SNN (Check System Error Log 1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S. before replacing a FRU. S = number of failing PCI slot; NN = SCSI ID of failing fixed disk.) 035-253-S99 (RAID adapter initialization failure) 1. ServeRAID Adapter in slot S is not configured properly. Obtain the basic and extended configuration status and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable 3. Adapter 075-XXX-000 (Failed Power Supply test) 1. Power Supply 089-XXX-001 1. Microprocessor (Failed Microprocessor test) 180-XXX-003 (Failed System Board LED test) 1. System Board 201-XXX-0NN (Failed Memory test, see ″Memory Settings″ on page 27.) NN = DIMM location. 1. DIMM Location J1-J4 2. Memory card 201-XXX-999 (Multiple DIMM failure, see error text.) 1. See error text for failing DIMMs 202-XXX-001 (Failed System Cache test) 1. Microprocessor CPU 1 Symptom-to-FRU index 91

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

Error
Code/Symptom
FRU/Action
015-XXX-015
(Failed
USB
External
Loopback
test)
1.
Make
sure
parallel
port
is
not
disabled
2.
Re-run
USB
External
Loopback
test
3.
System
Board
015-XXX-198
(USB
device
connected
during
USB
test)
1.
Remove
USB
devices
from
USB1
and
USB2
2.
Re-run
test
3.
System
Board
020-XXX-000
(Failed
PCI
Interface
test)
1.
System
Board
030-XXX-000
(Failed
Internal
SCSI
interface
test)
1.
System
Board
030-XXX-00N
(Failed
SCSI
test
on
PCI
slot
N.
Check
system
error
log
before
replacing
a
FRU.)
1.
Adapter
in
Slot
N
035-XXX-099
1.
No
adapters
were
found.
2.
If
adapter
is
installed
re-check
connection.
035-XXX-S99
(Failed
RAID
test
on
PCI
slot
S.
S
=
number
of
failing
PCI
slot.
Check
System
Error
Log
before
replacing
a
FRU.)
1.
Adapter
2.
SCSI
Backplane
3.
Cable
035-XXX-SNN
(Check
System
Error
Log
before
replacing
a
FRU.
S
=
number
of
failing
PCI
slot;
NN
=
SCSI
ID
of
failing
fixed
disk.)
1.
Fixed
Disk
with
SCSI
ID
NN
on
RAID
adapter
in
PCI
slot
S.
035-253-S99
(RAID
adapter
initialization
failure)
1.
ServeRAID
Adapter
in
slot
S
is
not
configured
properly.
Obtain
the
basic
and
extended
configuration
status
and
refer
to
the
ServeRAID
Hardware
Maintenance
Manual
for
more
information.
2.
Cable
3.
Adapter
075-XXX-000
(Failed
Power
Supply
test)
1.
Power
Supply
089-XXX-001
(Failed
Microprocessor
test)
1.
Microprocessor
180-XXX-003
(Failed
System
Board
LED
test)
1.
System
Board
201-XXX-0NN
(Failed
Memory
test,
see
Memory
Settings
on
page
27.)
NN
=
DIMM
location.
1.
DIMM
Location
J1-J4
2.
Memory
card
201-XXX-999
(Multiple
DIMM
failure,
see
error
text.)
1.
See
error
text
for
failing
DIMMs
202-XXX-001
(Failed
System
Cache
test)
1.
Microprocessor
CPU
1
Symptom-to-FRU
index
91