USB Universal Serial Bus PORT, CI-V REMOTE CONTROL JACK [REMOTE] - mods

Page 19 highlights

1 PANEL DESCRIPTION u STRAIGHT KEY JACK [KEY] (p. 2-5) Connect a straight key or external electronic keyer using a standard 3.5(d) mm/ 1⁄8 inch plug. • To use the internal electronic keyer for CW operation, connect to [ELEC-KEY] on the Front panel of the Controller. (p. 1-13) (+) (_) i ACCESSORY SOCKET [ACC] Connect control lines for external equipment such as a linear amplifier, an automatic antenna selector/ tuner, a TNC for data communications, and so on. • See page 1-16 for socket information. o DATA1 JACK [DATA1] (p. 2-6) ➥ Connect a PC through the optional OPC-1529R data communication cable, for low-speed data communication in the DV mode. (AI sec. 9) ➥ Connect a GPS receiver through the optional OPC-1529R data communication cable, for GPS operation. (AI sec. 10) !0 DATA2 SOCKET [DATA2] (p. 2-6) Connect a TNC (Terminal Node Controller), and so on, for high speed data communications. !1 C I-V REMOTE CONTROL JACK [REMOTE] (p. 2-6) ➥ Connect a PC, using the optional CT-17 ci-v level converter, for external control of the transceiver. ➥ Use for the transceive function with another Icom CI-V transceiver or receiver. When the transceive function is set to ON, changing the frequency, operating mode and so on, on the IC-7100 automatically changes those settings on other Icom transceivers or receivers, and vice versa. ➥ Connect another IC-7100, using a mini plug cable*, for transceiver to transceiver cloning. * Purchase separately !2 USB (Universal Serial Bus) PORT [USB] Using a USB cable, connect a PC to do the follow- ing: - Input modulation - Remotely control the transceiver using CI-V com- mands (AI sec. 20) - Send the received audio to the PC - S end the decoded characters to the PC - Low-speed data communication in the DV mode (AI sec. 9) - Cloning using the optional CS-7100 cloning soft- ware (AI sec. 21) - Remote control operation using the optional RSBA1 ip remote control software (AI sec. 21) • T wo COM port numbers are assigned to the [USB] connector. One of them is "USB1," used for cloning and CI-V operation. The other one is "USB2," whose function is selected in "USB2 Function" item of the "Connectors" Set mode. (p. 6-8) SET > Connectors > USB2/DATA1 Function > USB2 Function About the USB driver: The USB driver and the installation guide can be downloaded from our website. ➥ http://www.icom.co.jp/world/index.html The following items are required: PC • Microsoft® Windows® XP, Microsoft® Windows Vista®, Microsoft® Windows® 7 or Microsoft® Windows® 8 OS • A USB 1.1 or 2.0 port Other items • USB cable (supplied with the transceiver) • PC software (such as the optional RS-BA1 or CS- 7100) NEVER connect the transceiver to a PC until the USB driver installation has been completed. About the modulation input: Select "USB" in the "Connectors" Set mode item "DATA OFF MOD" or "DATA MOD." The modulation input level from the USB jack can be set in the Set mode item "USB MOD Level." (AI sec. 6) SET > Connectors > DATA OFF MOD SET > Connectors > DATA MOD SET > Connectors > USB MOD Level While cloning using the CS-7100 software, DO NOT connect anything to the [REMOTE] jack. !3 E XTERNAL SPEAKER JACK [SP] Connect to an external speaker (4 to 8 ø). !4 MICROPHONE CONNECTOR [MIC] Plug in the supplied or an optional microphone. • See AI sec. 21 for appropriate microphones. • See p. 1-17 for microphone connector information. • T he optional OPC-589 cable can be used to connect an 8-pin microphone such as the SM-30 or SM-50. • A microphone connector is also available on the Controller. DO NOT simultaneously connect two microphones. 1-15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

1
PANEL DESCRIPTION
1-15
u
STRAIGHT KEY JACK [KEY]
(p. 2-5)
Connect a straight key or external electronic keyer
using a standard 3.5(d) mm/
1
8
inch plug.
To use the internal electronic keyer for CW operation,
connect to [ELEC-KEY] on the Front panel of the Con-
troller. (p. 1-13)
(
+
)
(
_
)
i
ACCESSORY SOCKET [ACC]
Connect control lines for external equipment such
as a linear amplifier, an automatic antenna selector/
tuner, a TNC for data communications, and so on.
• See page 1-16 for socket information.
o
DATA1 JACK [DATA1]
(p. 2-6)
Connect a PC through the optional OPC-1529R
DATA
COMMUNICATION
CABLE
, for low-speed data
communication in the DV mode. (AI sec. 9)
Connect a GPS receiver through the optional
OPC-1529R
DATA
COMMUNICATION
CABLE
, for GPS
operation. (AI sec. 10)
!
0
DATA2 SOCKET [DATA2]
(p. 2-6)
Connect a TNC (Terminal Node Controller), and so
on, for high speed data communications.
!
1
CI-V REMOTE CONTROL JACK [REMOTE]
(p. 2-6)
Connect
a PC, using the optional CT-17
CI
-
V
LEVEL
CONVERTER
, for external control of the transceiver.
Use for the transceive function with another Icom
CI-V transceiver or receiver.
When the transceive function is set to ON, chang-
ing the frequency, operating mode and so on, on
the IC-7100 automatically changes those settings
on other Icom transceivers or receivers, and vice
versa.
Connect another IC-7100, using a mini plug
cable*, for transceiver to transceiver cloning.
* Purchase separately
!
2
USB (Universal Serial Bus) PORT
[USB]
Using a USB cable, connect a PC to do the follow-
ing:
- Input modulation
- Remotely control the transceiver using CI-V com-
mands (AI sec. 20)
- Send the received audio to the PC
-
Send the decoded characters to the PC
- Low-speed data communication in the DV mode
(AI sec. 9)
- Cloning using the optional CS-7100
CLONING
SOFT
-
WARE
(AI sec. 21)
- Remote control operation using the optional RS-
BA1
IP
REMOTE
CONTROL
SOFTWARE
(AI sec. 21)
• Two COM port numbers are assigned to the [USB] con
-
nector. One of them is “USB1,” used for cloning and CI-V
operation. The other one is “USB2,” whose function is se-
lected in “USB2 Function” item of the “Connectors” Set
mode. (p. 6-8)
SET
> Connectors > USB2/DATA1 Function >
USB2 Function
About the USB driver:
The USB driver and the installation guide can be
downloaded from our website.
The following items are required:
PC
• Microsoft
®
Windows
®
XP,
Microsoft
®
Windows Vista
®
,
Microsoft
®
Windows
®
7 or
Microsoft
®
Windows
®
8 OS
• A USB 1.1 or 2.0 port
Other items
• USB cable (supplied with the transceiver)
• PC software (such as the optional RS-BA1 or CS-
7100)
NEVER
connect the transceiver to a PC until the
USB driver installation has been completed.
About the modulation input:
Select “USB” in the “Connectors” Set mode item
“DATA OFF MOD” or “DATA MOD.” The modulation
input level from the USB jack can be set in the Set
mode item “USB MOD Level.” (AI sec. 6)
SET
> Connectors >
DATA OFF MOD
SET
> Connectors >
DATA MOD
SET
> Connectors >
USB MOD Level
While cloning using the CS-7100 software, DO NOT
connect anything to the [REMOTE] jack.
!
3
EXTERNAL SPEAKER JACK [SP]
Connect to an external speaker (4 to 8
ø
).
!
4
MICROPHONE CONNECTOR [MIC]
Plug in the supplied or an optional microphone.
• See AI sec. 21 for appropriate microphones.
• See p. 1-17 for microphone connector information.
• The optional OPC-589 cable can be used to connect an
8-pin microphone such as the SM-30 or SM-50.
• A microphone connector is also available on the Control
-
ler.
DO NOT