Icom IC-9700 Instruction Manual basic - Page 29

RF gain and SQL level, Dial Lock function, Transmit Power Limit function, Adjusting the transmit

Page 29 highlights

3 BASIC OPERATION RF gain and SQL level Rotate AF RF/SQL (outer) to adjust the RF gain and SQL level. By default, rotating left (when set to the 12 o'clock position) adjusts the RF gain, and rotating right adjusts the squelch level, as described below. Squelch is open Noise squelch (FM/DV mode) Maximum RF gain RF gain adjustable range is displayed Minimum RF gain S-meter squelch adjustable range Maximum S-meter squelch RF gain Adjust the RF gain to decrease the noise received from a nearby strong station. ••Rotate counterclockwise to reduce the RF gain, which reduces the receive sensitivity. "RFG" appears when AF RF/SQL is set to the counterclockwise from the 11 o'clock position. "RFG" indicates that the RF gain is reduced. LIf a strong signal is received and "OVF" (Overflow) appears, reduce the RF gain until "OVF" disappears. SQL level There are 2 types of SQL levels, depending on the operating mode. ••Noise squelch Rotate the AF RF/SQL (outer) until the noise just disappears and the TX/RX indicator goes OFF. ••S-meter squelch The S-meter squelch disables the audio output from the speaker or headphones when the received signal is weaker than the specified S-meter squelch level. Rotate the AF RF/SQL clockwise from the 12 o'clock position to increase the S-meter threshold level. L You can change the AF RF/SQL (outer) control type in "RF/SQL Control." (p. 3-10) MENU » SET > Function > RF/SQL Control Dial Lock function Adjusting the transmit output power Before transmitting, monitor your selected operating 1 frequency to make sure you do not cause interference to other stations on the same frequency. It is good amateur practice 2 to listen first, and then, even if nothing is heard, ask if the frequency in use once or twice, before you start operating. 3 DDAdjusting the transmit output power 4 1. Select the operating mode. (p. 3-3) (Example: USB) 2. Touch the meter to display the Po meter. (p. 3-11) 5 6 3. Open the Multi-function menu. 7 Push 8 9 4. Push TRANSMIT or hold down [PTT]. ••The Po meter level changes according to your voice level in the SSB mode. 10 11 ••The TX/RX indicator lights red and is displayed. LiLgihgthstsrerded 12 5. Touch "RF POWER." 6. Adjust the transmit output power to between 0 and 13 100%. ••The Po meter displays the RF output power in a percentage. It becomes the S-meter while receiving. 7. Push TRANSMIT or release [PTT]. ••Returns to receive. 14 15 16 Transmit Power Limit function 17 The Transmit Power Limit function limits the output 18 power to the preset level for each band. 1. On the FUNCTION set screen, touch [TX PWR LIMIT]. ••Each touch turns the function ON or OFF. 19 2. Touch [TX PWR LIMIT] for 1 second. 3. Rotate MULTI to set the maximum transmit power. 20 21 The Dial Lock function prevents frequency changes caused by accidently moving MAIN DIAL . LThis function electronically locks the dial. Hold down SPEECH for 1 second to turn the Dial Lock function ON or OFF. ••During Split Frequency operation, the Split Lock function may be turned ON. (p. 4-10) HoHlodlddodwownn MENU » SET > Function > Lock Function 4. Push MULTI to close the MENU. 3-10 Set transmit power Limited transmit power (LIMIT value) Even when set RF POWER exceeds "LIMIT," the actual output power is limited to this value.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

3
BASIC OPERATION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
3-10
RF gain and SQL level
Noise squelch (FM/DV mode)
Maximum RF gain
S-meter squelch
adjustable range
Maximum S-meter
squelch
Squelch is open
RF gain
adjustable range
Minimum RF gain
is displayed
Dial Lock function
Transmit Power Limit function
The Dial Lock function prevents frequency changes
caused by accidently moving
MAIN DIAL
.
L
This function electronically locks the dial.
The Transmit Power Limit function limits the output
power to the preset level for each band.
1.
On the FUNCTION set screen, touch [TX PWR LIMIT].
• Each touch turns the function ON or OFF.
2. Touch [
TX PWR LIMIT
] for 1 second.
3.
Rotate
MULTI
to set the maximum transmit power.
Adjusting the transmit output
power
Before transmitting, monitor your selected operating
frequency to make sure you do not cause interference to other
stations on the same frequency. It is good amateur practice
to listen first, and then, even if nothing is heard, ask if the
frequency in use once or twice, before you start operating.
D
Adjusting the transmit output power
1.
Select the operating mode. (p. 3-3) (Example: USB)
2.
Touch the meter to display the Po meter. (p. 3-11)
Push
3.
Open the Multi-function menu.
5.
Touch “RF POWER.”
6.
Adjust the transmit output power to between 0 and
100%.
• The Po meter displays the RF output power in a
percentage. It becomes the S-meter while receiving.
7. Push
TRANSMIT
or release [PTT].
• Returns to receive.
Hold down
SPEECH
for 1 second to turn the
Dial Lock function ON or OFF.
• During Split Frequency operation, the Split
Lock function may be turned ON. (p. 4-10)
MENU
»
SET > Function >
Lock Function
Hold down
Rotate
AF
RF/SQL
(outer) to adjust the RF gain and
SQL level.
By default, rotating left (when set to the 12 o’clock
position) adjusts the RF gain, and rotating right
adjusts the squelch level, as described below.
RF gain
Adjust the RF gain to decrease the noise received
from a nearby strong station.
• Rotate counterclockwise to reduce the RF gain, which
reduces the receive sensitivity. “RFG” appears when
AF
RF/SQL
is set to the counterclockwise from the 11 o’clock
position. “RFG” indicates that the RF gain is reduced.
L
If a strong signal is received and “OVF” (Overflow)
appears, reduce the RF gain until “OVF” disappears.
SQL level
There are 2 types of SQL levels, depending on the
operating mode.
Noise squelch
Rotate the
AF
RF/SQL
(outer) until the noise just
disappears and the TX/RX indicator goes OFF.
S-meter squelch
The S-meter squelch disables the audio output from
the speaker or headphones when the received signal is
weaker than the specified S-meter squelch level.
Rotate the
AF
RF/SQL
clockwise from the 12 o’clock
position to increase the S-meter threshold level.
L
You can change the
AF
RF/SQL
(outer) control type in
“RF/SQL Control.” (p. 3-10)
MENU
»
SET > Function >
RF/SQL Control
Lights red
4.
Push
TRANSMIT
or hold down [PTT].
• The Po meter level changes according
to your voice level in the SSB mode.
• The TX/RX indicator lights red and
is displayed.
4.
Push
MULTI
to close the MENU.
Set transmit power
Limited transmit power (LIMIT value)
Even when set RF POWER exceeds
“LIMIT,” the actual output power is
limited to this value.