Icom IC-9700 Instruction Manual basic - Page 30

Adjusting the microphone gain, Meter display

Page 30 highlights

3 BASIC OPERATION Meter display DDMeter display selection You can display one of the 6 different transmit parameters (Po, SWR, ALC, COMP, VD and ID) for your convenience. Touch the parameter to display one of the meters. DDMulti-function meter You can display all the parameters simultaneously. LThe TEMP meter is also displayed on the Multi-function meter. Hold down the parameter for 1 second to display the Multi-function meter. ALC meter ALC zone Adjusting the microphone gain Adjust the microphone gain as described below. 1. Set the operating band and mode to SSB, AM, FM or DV. (p. 3-3) Rotate 2. Push MULTI to display the Multi-function menu. 3. Touch "MIC GAIN," and rotate MULTI to adjust the microphone. LSetting "50%" can be used for most voice operations, but do following to make sure the microphone gain is properly set. ••Hold the microphone 5 to 10 cm (2 to 4 inches) from your mouth, then hold down [PTT] on the microphone and speak at your normal voice level. ••In the SSB mode, touch the TX meter to select the ALC meter, and rotate MULTI to adjust the microphone gain until the meter reading swings between 30 to 50% of the ALC scale. ••In the AM, FM or DV mode, check the audio clarity with another station, or use the Monitor function (p. 4-7). Multi-function meter TX inhibit zone When the VD meter reads on the red under line or below, the output power may decrease or transceiver power may be shut down. Displays the temperature of the final amplifier MOS-FETs. S: Displays the receiving signal strength level. Po: Displays the relative RF output power. SWR:  Displays the SWR of the antenna at the frequency. ALC: Displays the ALC level. When the meter movement shows the input signal level exceeds the allowed level, the ALC limits the RF power. In such cases, decrease the microphone gain level. COMP: Displays the compression level when the speech compressor is used. VD: Displays the drain voltage of the final amplifier MOS-FETs. ID:  Displays the drain current of the final amplifier MOS-FETs. TEMP: Displays the temperature of the final amplifier MOS-FETs. 3-11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

3
BASIC OPERATION
3-11
Rotate
Adjusting the microphone gain
Adjust the microphone gain as described below.
1.
Set the operating band and mode to SSB, AM, FM
or DV. (p. 3-3)
Meter display
D
Meter display selection
You can display one of the 6 different transmit
parameters (Po, SWR, ALC, COMP, VD and ID) for
your convenience.
Touch the parameter to display one of the meters.
D
Multi-function meter
You can display all the parameters simultaneously.
L
The TEMP meter is also displayed on the Multi-function
meter.
Hold down the parameter for 1 second to display the
Multi-function meter.
ALC meter
ALC zone
Multi-function meter
2. Push
MULTI
to display the Multi-function menu.
3.
Touch “MIC GAIN,” and rotate
MULTI
to adjust the
microphone.
L
Setting “50%” can be used for most voice operations,
but do following to make sure the microphone gain is
properly set.
Hold the microphone 5 to 10 cm (2 to 4 inches) from
your mouth, then hold down [PTT] on the microphone
and speak at your normal voice level.
• In the SSB mode, touch the TX meter to select
the ALC meter, and rotate
MULTI
to adjust the
microphone gain until the meter reading swings
between 30 to 50% of the ALC scale.
• In the AM, FM or DV mode, check the audio clarity with
another station, or use the Monitor function (p. 4-7).
S:
Displays the receiving signal strength level.
Po:
Displays the relative RF output power.
SWR:
Displays the SWR of the antenna at the
frequency.
ALC
:
Displays the ALC level. When the meter
movement shows the input signal level exceeds
the allowed level, the ALC limits the RF power.
In such cases, decrease the microphone gain
level.
COMP:
Displays the compression level when the
speech compressor is used.
VD:
Displays the drain voltage of the final amplifier
MOS-FETs.
ID:
Displays the drain current of the final amplifier
MOS-FETs.
TEMP:
Displays the temperature of the final amplifier
MOS-FETs.
When the VD meter
reads on the red under
line or below, the output
power may decrease or
transceiver power may be
shut down.
Displays the temperature of
the final amplifier MOS-FETs.
TX inhibit zone