Workaround, Status, Problem, Implication, SYSRET May Incorrectly Clear RF Resume Flag in the RFLAGS
UPC - 735858184625
View all Intel E6600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Errata Workaround: None identified. Status: For the steppings affected, see the Summary Tables of Changes. AI4. VERW/VERR/LSL/LAR Instructions May Unexpectedly Update the Last Exception Record (LER) MSR Problem: The LER MSR may be unexpectedly updated, if the resultant value of the Zero Flag (ZF) is zero after executing the following instructions 1) VERR (ZF=0 indicates unsuccessful segment read verification) 2) VERW (ZF=0 indicates unsuccessful segment write verification) 3) LAR (ZF=0 indicates unsuccessful access rights load) 4) LSL (ZF=0 indicates unsuccessful segment limit load) Implication: The value of the LER MSR may be inaccurate if VERW/VERR/LSL/LAR instructions are executed after the occurrence of an exception. Workaround: Software exception handlers that rely on the LER MSR value should read the LER MSR before executing VERW/VERR/LSL/LAR instructions. Status: For the steppings affected, see the Summary Tables of Changes. AI5. DR3 Address Match on MOVD/MOVQ/MOVNTQ Memory Store Instruction May Incorrectly Increment Performance Monitoring Count for Saturating SIMD Instructions Retired (Event CFH) Problem: Performance monitoring for Event CFH normally increments on saturating SIMD instruction retired. Regardless of DR7 programming, if the linear address of a retiring memory store MOVD/MOVQ/MOVNTQ instruction executed matches the address in DR3, the CFH counter may be incorrectly incremented. Implication: The value observed for performance monitoring count for saturating SIMD instructions retired may be too high. The size of the error is dependent on the number of occurrences of the conditions described above, while the counter is active. Workaround: None Identified. Status: For the steppings affected, see the Summary Tables of Changes. AI6. SYSRET May Incorrectly Clear RF (Resume Flag) in the RFLAGS Register Problem: In normal operation, SYSRET will restore the value of RFLAGS from R11 (the value previously saved upon execution of the SYSCALL instruction). Due to this erratum, the RFLAGS.RF bit will be unconditionally cleared after execution of the SYSRET instruction. Implication: The SYSRET instruction can not be used if the RF flag needs to be set after returning from a system call. Intel has not observed this erratum with any commercially available software. 24 Intel® Core™2 Extreme Processor X6800 and Intel® Core™2 Duo Desktop Processor E6000 and E4000 Sequence Specification Update