Intel S2600CP S2600CP/P4000CP family Service Guide - Page 68

Installing 8x3.5 Hot-swap Hard Drive Cage Assembly

Page 68 highlights

Hardware Installations and Upgrades Installing 8x3.5" Hot-swap Hard Drive Cage Assembly CAUTION It is critical that you connect the SAS/SATA data cables correctly from the SAS/SATA backplane to your server board or RAID controller card. Failure to do so may result in data loss. 1. Observe the safety and ESD precautions at the beginning of this book. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the chassis cover. For instructions, see "Removing the Chassis Cover". 4. Remove the front bezel if it is installed. For instructions, see "Removing the Front Bezel (Pedestal Only)". 5. Remove the Fixed HDD EMI Shield and Fixed HDD Tray if they are installed. For instructions, see "Removing the Fixed HDD Tray" and "Removing the Fixed HDD EMI Shield" 6. Install the 8x3.5" Hot-Swap Hard Drive Cage. A. Slide the 8x3.5" Hot-Swap Drive Cage into the slot (see letter "A"). B. Secure the Hard Drive Cage with the Screw (see letter "B"). Figure 88. Installing the 8x3.5" Hot-Swap Hard Drive Cage Assembly 7. Make the backplane and server board/RAID controller card cable connections. Refer to the documentation for your server board and/or RAID controller card for instructions on connecting backplane cables to your server board or RAID controller card. A. Connect an I2C cable (letter "A`"). B. Connect Mini SAS data cables (letter "B"). C. Connect power cable (letter "C"). 54 Intel® Server Board S2600CP Intel® Server System P4000CP Family Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187

Hardware Installations and Upgrades
54
Intel
®
Server Board S2600CP Intel
®
Server System P4000CP Family Service Guide
Installing 8x3.5” Hot-swap Hard Drive Cage Assembly
CAUTION
It is critical that you connect the SAS/SATA data cables correctly from the SAS/SATA
backplane to your server board or RAID controller card. Failure to do so may result in
data loss.
1.
Observe the safety and ESD precautions at the beginning of this book.
2.
Power down the server and unplug all peripheral devices and the AC power cable.
3.
Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4.
Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel
(Pedestal Only)”.
5.
Remove the Fixed HDD EMI Shield and Fixed HDD Tray if they are installed. For
instructions, see
Removing the Fixed HDD Tray” and
Removing the Fixed HDD EMI
Shield”
6.
Install the 8x3.5” Hot-Swap Hard Drive Cage.
A.
Slide the 8x3.5” Hot-Swap Drive Cage into the slot (see letter “A”).
B.
Secure the Hard Drive Cage with the Screw (see letter
B”).
Figure 88. Installing the 8x3.5” Hot-Swap Hard Drive Cage Assembly
7.
Make the backplane and server board/RAID controller card cable connections. Refer to the
documentation for your server board and/or RAID controller card for instructions on
connecting backplane cables to your server board or RAID controller card.
A.
Connect an I2C cable (letter “A`”).
B.
Connect Mini SAS data cables (letter “B”).
C.
Connect power cable (letter “C”).