LiftMaster GH GT- Logic 4 Installation Manual - Page 13

Hoist And Jackshaft Operators - 75 11

Page 13 highlights

HOIST AND JACKSHAFT HOIST AND JACKSHAFT OPERATORS CARTON INVENTORY Before beginning your installation check that all components were provided. DESCRIPTION Powerhead assembly Owner's manual and caution labels Hardware box (includes fasteners, track spacers, trolley, door arm assembly, front idler and header mounting bracket) 3-Button control station with LED Hoist hand chain (Models H, HJ and GH ONLY) Door sprocket Door/operator drive chain Entrapment Protection Device: Model CPS-U photoelectric sensors (standard) OPERATOR SPECIFICATIONS MOTOR TYPE Continuous duty HORSEPOWER: Model J, H and HJ 1/3, 1/2, 3/4 and 1 HP Model GH 1/2, 3/4, 1, 1-1/2, 2 and 3 HP SPEED 1725 RPM VOLTAGE: Model J, H and HJ 115/230V 1 Phase 208/230/460/575V 3 Phase Model GH 115/230V 1 Phase 208/230/460/575V 3 Phase CURRENT (Amperage): Models H, HJ, and J Voltage-Phase 1/3 HP 1/2 HP 3/4 HP 1 HP 115-1Ø, 60Hz 8.5 11.2 13.6 16 230-1Ø, 60Hz 4.2 5.6 6.8 8 208/230-3Ø, 60Hz 3 3.1 4 6 460-3Ø, 60Hz 1.5 1.75 2 3 575-3Ø, 60Hz 1.3 1.4 1.6 1.8 Model GH Voltage-Phase 1/2 HP 3/4 HP 1 HP 1-1/2 HP 2 HP 3 HP 115-1Ø, 60Hz 11.2 13.6 16 20 - - 230-1Ø, 60Hz 5.6 6.8 8 10 - - 208/230-3Ø, 60Hz 3.1 4 6 7 8 10.6 460-3Ø, 60Hz 1.75 2 3 3.5 4 4.8 575-3Ø, 60Hz 1.4 1.6 1.8 2.75 3 - ELECTRICAL TRANSFORMER 24Vac Secondary CONTROL STATION NEMA 3-Button Station Open/Close/Stop w/LED WIRING TYPE C2 (Standard) Momentary contact to OPEN and STOP, constant pressure to CLOSE, plus wiring for sensing device to reverse and auxiliary devices to open and close with open override. See page 29 for optional wiring types and operating modes. LIMIT ADJUST Linear driven, fully adjustable screw type cams. Adjustable to 24 feet. SAFETY DISCONNECT: Model J . . . . .Floor level disconnect for manual door operation Model H and GH Floor level chain hoist with electrical interlock for manual door operation Model HJ Includes both floor level disconnect systems stated above ENTRAPMENT PROTECTION: LiftMaster Monitored Entrapment Protection (LMEP) Photoelectric Sensors (CPS-U Through beam used to provide non-contact safety protection. Safety Edge (Optional Electric or pneumatic sensing device attached to the bottom edge of door. 13 Carton inventory/Operator specifications - Hoist and Jackshaft

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

13
HOIST AND JACKSHAFT
Carton inventory/Operator specifications - Hoist and Jackshaft
OPERATOR SPECIFICATIONS
CARTON INVENTORY
Before beginning your installation check that all components were provided.
DESCRIPTION
Powerhead assembly
Owner’s manual and caution labels
Hardware box (includes fasteners, track spacers, trolley, door arm assembly, front idler and header mounting bracket)
3-Button control station with LED
Hoist hand chain (Models H, HJ and GH ONLY)
Door sprocket
Door/operator drive chain
Entrapment Protection Device: Model CPS-U photoelectric sensors (standard)
HOIST AND JACKSHAFT OPERATORS
MOTOR
TYPE:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous duty
HORSEPOWER:
Model J, H and HJ . . . . . . . . . . . . . . . . 1/3, 1/2, 3/4 and 1 HP
Model GH . . . . . . . . . . . . . . . . .1/2, 3/4, 1, 1-1/2, 2 and 3 HP
SPEED:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1725 RPM
VOLTAGE:
Model J, H and HJ . . . . . . . . . . . . . . . . . . . .115/230V 1 Phase
208/230/460/575V 3 Phase
Model GH . . . . . . . . . . . . . . . . . . . . . . . . . .115/230V 1 Phase
208/230/460/575V 3 Phase
CURRENT (Amperage):
Models H, HJ, and J
Voltage-Phase
1/3 HP
1/2 HP
3/4 HP
1 HP
115-1Ø, 60Hz
8.5
11.2
13.6
16
230-1Ø, 60Hz
4.2
5.6
6.8
8
208/230-3Ø, 60Hz
3
3.1
4
6
460-3Ø, 60Hz
1.5
1.75
2
3
575-3Ø, 60Hz
1.3
1.4
1.6
1.8
Model GH
Voltage-Phase
1/2 HP 3/4 HP 1 HP 1-1/2 HP 2 HP 3 HP
115-1Ø, 60Hz
11.2
13.6
16
20
-
-
230-1Ø, 60Hz
5.6
6.8
8
10
-
-
208/230-3Ø, 60Hz 3.1
4
6
7
8
10.6
460-3Ø, 60Hz
1.75
2
3
3.5
4
4.8
575-3Ø, 60Hz
1.4
1.6
1.8
2.75
3
-
ELECTRICAL
TRANSFORMER:
. . . . . . . . . . . . . . . . . . . . . . . . 24Vac Secondary
CONTROL STATION:
. . . . . . . . . . . . . . . . NEMA 3-Button Station
Open/Close/Stop w/LED
WIRING TYPE:
. . . . . . . . . . . . . . . . . . . . . . . . . . . C2 (Standard)
Momentary contact to OPEN and STOP, constant pressure to
CLOSE, plus wiring for sensing device to reverse and auxiliary
devices to open and close with open override. See page 29 for
optional wiring types and operating modes.
LIMIT ADJUST:
. . . . . . . . . . Linear driven, fully adjustable screw
type cams. Adjustable to 24 feet.
SAFETY
DISCONNECT:
Model J . . . . .Floor level disconnect for manual door operation
Model H and GH . . . . . . . Floor level chain hoist with electrical
interlock for manual door operation
Model HJ . . . . . . . . . . . . . . Includes both floor level disconnect
systems stated above
ENTRAPMENT PROTECTION:
LiftMaster Monitored Entrapment Protection (LMEP)
Photoelectric Sensors (CPS-U):
. . . . . . . . . . . . .Through beam
used to provide non-contact safety protection.
Safety Edge (Optional):
. . . . . . . Electric or pneumatic sensing
device attached to the bottom edge of door.