LiftMaster GH GT- Logic 4 Installation Manual - Page 42

Logic Ver. 4.0 3 Phase Wiring Diagram

Page 42 highlights

LOGIC (VER. 4.0) 3 PHASE WIRING DIAGRAM 230V BRAKE (WHEN PRESENT) 230V BRAKE (WHEN PRESENT) 575V BRAKE (WHEN PRESENT) T4 T7 T1 J (GY) (BR) T5 T8 T2 (PU) (BR) J (YE) T6 T9 T3 (BL/BK) T4 T7 T1 J (GY) (BR) T5 T8 T2 (PU) 1 (GY) (BR) 2 (PU) (BR) J (YE) T6 T9 T3 (BR) 3 (YE) (BL/BK) 208/230V MOTOR CONNECTION 460V MOTOR CONNECTION 575V MOTOR CONNECTION NOTE: Gray (GY) and purple (PU) motor wires are reversed for H and HJ right hand models and all GH and J models. Sensing Edge Refer to page 26 for LiftMaster Monitored Entrapment Protection (LMEP) device connections Hoist Interlock When Present TMR DEF (BL) SWITCH (YE) Maintenance Alert LED (RD) (WH) Open Close Stop OPEN CLOSE STOP 3-Button Station Open/Close Single Button Remove Jumper To Install External Door Interlock DATA SBC STOP COMMON CLOSE OPEN EDGE: LMEP: 24VAC POWER 24VAC TIMER DEFEAT COMMON MAS TIMER ENABLE 3-PHASE 1-PHASE OLS MID SLS SLOT 1 SLOT 2 REV MOTOR STD DIRECTION CLS MRT MID TTC RADIO 1 2 3 T E2 D1 C2 B2 TS FSTS DIAG OPTN PROG RELAY A RELAY B (YE) (OR) (WH) (YE) (PU) (WH) (RD) (GY) (YE) (RD) (WH) (PU) (YE) (OR) (GY) L3 L2 L1 (BK) MOV MOV (WH) (WH) COM 120 240 / 460 / VAC 575 VAC (YE) +24 VAC -24 VAC (PU) (BR) See Motor (BR) Connections (WH) NO (WH) COM D (WH) COIL (WH) NO COM C COIL 0 B1 48 (WH) 26 (GY) 208/230/460 VOLT 3PH. POWER IN NOTE: Lock Sensor is provided on Models DJ and DH only, red wire from main harness connects to NC on BYPASS L/S and to NO on LOCK SENSOR switch. White wires connect the COM on BYPASS L/S and Lock Sensor switch to NC on Open L/S. (WH) COM OPEN L/S NO NC (RD) (PU) (WH) COM NO CLOSE L/S NC (YE) NOTE: The Lock Sensor switch is located in the chassis. (WH) LOCK (RD) NO SENSOR (see note at left) NC (WH) NC SAFETY L/S NO COM (WH) (RD) NO NC COM BYPASS L/S 1 2 3 4 RPM Board 42 (WH) (RD) (YE) (GY) (WH) (OR) (YE) (WH) (WH) (WH) (WH) (WH) (PU) (OR) 01 A 48 26 (GY) (YE) See Motor Connections R1 R2 R3 Radio Wiring Diagrams WIRING DIAGRAMS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

42
WIRING DIAGRAMS
Wiring Diagrams
SLOT
1
RADIO
SLS
MRT
MID
TTC
DATA
24VAC
24VAC
LMEP:
EDGE:
OPEN
CLOSE
STOP
COMMON
RELAY
A
RELAY
B
SBC
MAS
COMMON
TIMER
DEFEAT
POWER
TIMER
ENABLE
1
2
3
FSTS
DIAG
OPTN
PROG
T
TS
E2
D1
C2
B2
CLS
OLS
MID
REV
STD
SLOT
2
MOTOR
DIRECTION
3-PHASE
1-PHASE
Remove Jumper
To Install External
Door Interlock
3-Button Station
Maintenance
Alert LED
(RD)
(WH)
Open
Close
Stop
Open/Close
Single Button
Sensing
Edge
Hoist Interlock
When Present
TMR DEF
SWITCH
MOV
MOV
NOTE:
Lock Sensor is provided on Models
DJ and DH only, red wire from main harness
connects to NC on BYPASS L/S and to NO on
LOCK SENSOR switch. White wires connect the
COM on BYPASS L/S and Lock Sensor switch to
NC on Open L/S
.
(WH)
(WH)
(WH)
(RD)
(PU)
(YE)
COM
NO
NC
NO
NC
COM
NO
NC
COM
OPEN
L/S
NO
NC
LOCK
SENSOR
(see note at left)
CLOSE
L/S
SAFETY
L/S
(WH)
(RD)
(YE)
(BL)
(YE)
(OR)
(WH)
(YE)
(PU)
(WH)
(RD)
(GY)
(YE)
(RD)
(WH)
(PU)
(YE)
(OR)
(GY)
(OR)
(PU)
(WH)
(WH)
(WH)
(WH)
(WH)
(WH)
(GY)
(YE)
(WH)
(GY)
(WH)
(WH)
(WH)
(WH)
(WH)
(PU)
(BR)
(BR)
(YE)
208/230/460
VOLT 3PH.
POWER IN
(BK)
COM
120
VAC
240 / 460 /
575
VAC
+24 VAC
-24 VAC
COIL
COIL
COM
COM
NO
NO
See Motor
Connections
See Motor
Connections
8
0
1
4
6
2
6
2
8
4
0
1
A
B
C
D
OPEN
CLOSE
STOP
NOTE:
Gray (GY) and purple (PU) motor
wires are reversed for H and HJ right hand
models and all GH and J models.
575V BRAKE
(WHEN PRESENT)
1
2
3
(GY)
(BR)
(PU)
(BR)
(BL/BK)
(BL/BK)
(YE)
230V BRAKE
(WHEN PRESENT)
J
T4
T7
T1
T5
T8
T2
T6
T9
T3
(GY)
(BR)
(PU)
(BR)
(YE)
J
230V BRAKE
(WHEN PRESENT)
J
T4
T7
T1
T5
T8
T2
T6
T9
T3
(GY)
(BR)
(PU)
(BR)
(YE)
J
208/230V MOTOR CONNECTION
460V MOTOR CONNECTION
575V MOTOR CONNECTION
(WH)
(RD)
(YE)
(GY)
(WH)
(OR)
(YE)
1
2
3
4
RPM Board
Radio
R1
R2
R3
L3
L2
L1
Refer to page 26 for
LiftMaster Monitored
Entrapment Protection (LMEP)
device connections
NOTE:
The Lock Sensor switch is
located in the chassis.
(RD)
COM
NO
NC
BYPASS
L/S
(WH)
LOGIC (VER. 4.0) 3 PHASE WIRING DIAGRAM