LiftMaster GH GT- Logic 4 Installation Manual - Page 29

Determine And Set Wiring Type - wiring diagram

Page 29 highlights

DETERMINE AND SET WIRING TYPE Read the descriptions of the different wiring types to determine which setting will be correct for each application. Once the wiring type is determined, set the selector dial accordingly. LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP) DEVICE IS REQUIRED A LiftMaster Entrapment Protection (LMEP) device is required for the following wiring types. LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP) DEVICE IS RECOMMENDED A LiftMaster Entrapment Protection (LMEP) device is recommended for the following wiring types. B2 Momentary contact to open, close and stop, plus wiring for sensing device to reverse and auxiliary devices to open and close with open override. Programmable mid stop available with this wiring type. Compatible with 3-Button Station, 1-Button Station, 1 and 3-Button Remote Control. TS (TIMER SECURE) This mode will attempt to close the door from any position except when fully closed, or when a safety input is present. The stop button will not disable the Timer-To-Close at any position. To disable the Timer-To-Close in this mode, installation of a defeat switch is required (see wiring diagram). Momentary contact to open, close, and stop with open override and Timer-To-Close. Every device that causes door to open, including a reversing device, activates the Timer-To-Close. Auxiliary controls can be connected to open input to activate the Timer-To-Close. If the timer has been activated, the open button and radio control can recycle the timer. The Timer-To-Close will function from the programmable mid stop with this wiring type. Compatible with 3-Button Station, 1-Button Station and 1 and 3-Button Remote Control. NOTE: A Programmable "Car Dealer Mode" available. T Momentary contact to open, close, and stop, with open override and Timer-To-Close. Every device that causes the door to open, except any safety edge input device, activates the Timer-To-Close. Auxiliary controls can be connected to open input to activate the Timer-To-Close. If the Timer-To-Close has been activated, the open button and radio control can recycle the timer. The stop button will deactivate the timer until the next command input. The Timer-To-Close will function from the programmable mid stop with this wiring type. Compatible with 3-Button Station,1-Button Station and 1 and 3-Button Remote Control. NOTE: Programmable "Car Dealer Mode" available. FSTS Momentary button contact for open, close and stop programming. User set mid stop. User set Timer-To-Close. The single button station opens the door to the full open limit bypassing the mid stop and activates the Timer-To-Close, putting the operator in TS mode until the door reaches the down limit, or is stopped in travel. At which time the operator enters the B2 mode. Compatible with 3-Button Station, 1-Button Station, 1 and 3-Button Remote Control. A 1-Button remote control in FSTS mode will open only with the Timer-To-Close, bypassing a programmed mid stop. The Timer-To-Close will reset and reverse when closing. C2 Momentary contact to open and stop with constant pressure to close, open override plus wiring for sensing device to reverse. Programmable mid stop available with this wiring type. Compatible with 3-Button Station and 1-Button Station. E2 Momentary contact to open with override and constant pressure to close. Release of close button will cause door to reverse (roll-back feature) plus wiring for sensing device to reverse. Compatible with 3-Button Station. D1 Constant pressure to open and close with wiring for sensing device to stop. Compatible with 2 or 3-Button Station. SELECTOR DIAL T E2 D1 C2 B2 TS FSTS DIAG OPTN PROG IMPORTANT NOTES: 1. External interlocks may be used with all functional modes. 2. Auxiliary devices are any devices that have only dry contacts. Examples: photocell, loop detector, pneumatic or electrical treadles, radio controls, one button stations, pull cords, etc. 3. Open override means that the door may be reversed while closing by activating an opening device without the need to use the stop button first. 4. When the door is in a stopped position other than fully closed, and a safety input is activated (LMEP or EDGE), the Restricted Close (RC) feature will allow a close command when the close button is pressed and held. The operator will begin closing after 5 seconds. If the close button is released the door will stop. When in E2 mode, the door will move to the fully open position. PROGRAMMING 29 Programming - Determine and set wiring type

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

29
PROGRAMMING
DETERMINE AND SET WIRING TYPE
Read the descriptions of the different wiring types to determine which setting will be correct for each application. Once the wiring type
is determined, set the selector dial accordingly.
OPTN
PROG
DIAG
FSTS
TS
T
E2
D1
C2
B2
SELECTOR DIAL
Programming - Determine and set wiring type
IMPORTANT NOTES:
1.
External interlocks may be used with all functional modes.
2.
Auxiliary devices are any devices that have only dry contacts.
Examples: photocell, loop detector, pneumatic or electrical
treadles, radio controls, one button stations, pull cords, etc.
3.
Open override means that the door may be reversed while
closing by activating an opening device without the need to use
the stop button first.
4. When the door is in a stopped position other than fully closed,
and a safety input is activated (LMEP or EDGE), the Restricted
Close (RC) feature will allow a close command when the close
button is pressed and held. The operator will begin closing after
5 seconds. If the close button is released the door will stop.
When in E2 mode, the door will move to the fully open position.
LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP)
DEVICE IS REQUIRED
A LiftMaster Entrapment Protection (LMEP) device is
required
for
the following wiring types.
LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP)
DEVICE IS RECOMMENDED
A LiftMaster Entrapment Protection (LMEP) device is
recommended for the following wiring types.
B2
Momentary contact to open, close and stop, plus wiring for
sensing device to reverse and auxiliary devices to open and
close with open override. Programmable mid stop available
with this wiring type.
Compatible with 3-Button Station,
1-Button Station, 1 and 3-Button Remote Control.
TS (TIMER SECURE)
This mode will attempt to close the door from any position
except when fully closed, or when a safety input is present.
The stop button will not disable the Timer-To-Close at any
position. To disable the Timer-To-Close in this mode,
installation of a defeat switch is required (see wiring
diagram).
Momentary contact to open, close, and stop with open
override and Timer-To-Close. Every device that causes
door to open, including a reversing device, activates the
Timer-To-Close. Auxiliary controls can be connected to open
input to activate the Timer-To-Close. If the timer has been
activated, the open button and radio control can recycle the
timer. The Timer-To-Close will function from the
programmable mid stop with this wiring type.
Compatible
with 3-Button Station, 1-Button Station and 1 and 3-Button
Remote Control
.
NOTE:
A Programmable “Car Dealer Mode” available.
T
Momentary contact to open, close, and stop, with open
override and Timer-To-Close. Every device that causes
the door to open, except any safety edge input device,
activates the Timer-To-Close. Auxiliary controls can be
connected to open input to activate the Timer-To-Close.
If the Timer-To-Close has been activated, the open button
and radio control can recycle the timer. The stop button will
deactivate the timer until the next command input. The
Timer-To-Close will function from the programmable
mid stop with this wiring type.
Compatible with 3-Button
Station,1-Button Station and 1 and 3-Button Remote
Control
.
NOTE:
Programmable “Car Dealer Mode” available.
FSTS
Momentary button contact for open, close and stop
programming. User set mid stop. User set Timer-To-Close.
The single button station opens the door to the full
open limit bypassing the mid stop and activates the
Timer-To-Close, putting the operator in TS mode until the
door reaches the down limit, or is stopped in travel. At
which time the operator enters the B2 mode.
Compatible with 3-Button Station, 1-Button Station, 1 and
3-Button Remote Control.
A 1-Button remote control in
FSTS mode will open only with the Timer-To-Close,
bypassing a programmed mid stop. The Timer-To-Close will
reset and reverse when closing.
C2
Momentary contact to open and stop with constant pressure
to close, open override plus wiring for sensing device to
reverse. Programmable mid stop available with this wiring
type.
Compatible with 3-Button Station and 1-Button
Station.
E2
Momentary contact to open with override and constant
pressure to close. Release of close button will cause door to
reverse (roll-back feature) plus wiring for sensing device to
reverse.
Compatible with 3-Button Station.
D1
Constant pressure to open and close with wiring for sensing
device to stop.
Compatible with 2 or 3-Button Station.