Motorola V186 User Manual - Page 50

Digital Output and Digital Input FET Modules, Parameter, Selection, Default, Setup, Per Module, Input

Page 50 highlights

Digital Output and Digital Input FET Modules Each DI can be set in the Application Programmer I/O link table to trigger recording of time tagged events upon any input change of state. The time tagged events are recorded in the CPU memory and can be retrieved for various purposes. Each input can be configured to KLV or to a PDV (0, 1) in the Application Programmer I/O link table. This value is shown to the user application program in the event of DI module failure. Also, the predefined value can be used during normal operation to force a value that masks the actual input value. In this case the user application program will get the PDV instead of the actual input value. Each output can be configured to "Keep Last Value" KLV or to a "Predefined Value" PDV (0, 1). This value is executed when the user application program stops or when the module has no communication with the CPU module. Also, the predefined value can be used during normal operation to force a value on the output by ignoring the user application program value. The DO/DI FET module features which can be configured are listed in the table below. Some parameters are per module and some are per input. Parameter Selection DI Fast Capture DI Filter* Disabled /Enabled 0-254 (x 0.2 mS) DI Counter Filter* 0-255 (x 0.05 mS) DI Event Time Tagging Disabled /Enabled DI Keep Last Value & Predefined Value DI Mask KLV/PDV PDV = 0/1 No /Yes DO Keep Last Value & Predefined Value KLV/PDV PDV = 0/1 Default Setup Disabled 50 (10 mS) 20 (1 ms) Disabled KLV No KLV Per Module/ Input Input Module Module Input Input Input Output Parameter Setup Location RTU configuration RTU configuration; 'C' Program RTU configuration; 'C' Program Application Programmer I/O link table Application Programmer I/O link table Application Programmer I/O link table Application Programmer I/O link table * The counters are limited to 1Khz; therefore filtering is relevant from 1mS and above. In this module the minimum relevant value for DI Filter is 5 and the minimum value for DI Counter Filter is 20. 46

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185

Digital Output and Digital Input FET Modules
Each DI can be set in the Application Programmer I/O link table to trigger recording of
time tagged events upon any input change of state. The time tagged events are recorded
in the CPU memory and can be retrieved for various purposes.
Each input can be configured to KLV or to a PDV (0, 1) in the Application Programmer
I/O link table. This value is shown to the user application program in the event of DI
module failure. Also, the predefined value can be used during normal operation to force a
value that masks the actual input value. In this case the user application program will get
the PDV instead of the actual input value.
Each output can be configured to “Keep Last Value” KLV or to a “Predefined Value”
PDV (0, 1). This value is executed when the user application program stops or when the
module has no communication with the CPU module.
Also, the predefined value can be used during normal operation to force a value on the
output by ignoring the user application program value.
The DO/DI FET module features which can be configured are listed in the table below.
Some parameters are per module and some are per input.
Parameter
Selection
Default
Setup
Per Module/
Input
Parameter Setup
Location
DI Fast Capture
Disabled /Enabled
Disabled
Input
RTU configuration
DI Filter
*
0-254 (x 0.2 mS)
50 (10 mS)
Module
RTU configuration;
‘C’ Program
DI Counter Filter
*
0-255 (x 0.05 mS)
20 (1 ms)
Module
RTU configuration;
‘C’ Program
DI Event Time
Tagging
Disabled /Enabled
Disabled
Input
Application
Programmer I/O link
table
DI Keep Last
Value &
Predefined Value
KLV/PDV
PDV = 0/1
KLV
Input
Application
Programmer I/O link
table
DI Mask
No /Yes
No
Input
Application
Programmer I/O link
table
DO Keep Last
Value &
Predefined Value
KLV/PDV
PDV = 0/1
KLV
Output
Application
Programmer I/O link
table
*
The counters are limited to 1Khz; therefore filtering is relevant from 1mS and above.
In this module the
minimum relevant value for DI Filter is 5 and the minimum value for DI Counter Filter is 20.
46