Motorola V186 User Manual - Page 62

two expansion Ethernet switches on the main frame and thirteen I/O expansion frames.

Page 62 highlights

I/O Expansion Note: The number of expansion power supplies that can be cascaded to the power supply on the main frame is limited. When required, optional DC or AC power supplies should be installed on the expansion frames to meet the accumulated power consumption and voltage level requirements. In the maximal configuration, up to 110 I/Os can be connected to the ACE3600, by using two expansion Ethernet switches on the main frame and thirteen I/O expansion frames. See the figure below. Main Rack Main PS (AC/DC) CPU 3640 Expansion Switch 1 Expansion Switch 2 Communication Cables LAN Cable PS (AC) Expansion Module Radio/Batt. Chassis LAN Cable LAN Cable I/O Rack #7 I/O Rack #8 I/O Rack #13 DC Cable LAN Cable LAN Cable LAN Cable Expansion PS (DC) Expansion Module I/O Rack #1 I/O Rack #2 I/O Rack #6 ACE3600 I/O Expansion - Maximal I/O Configuration The following table shows the various configurations per required number of I/O slots: Number of I/O 0-8 9-16 17-23 24-31 32-39 40-47 48-55 56-63 64-70 71-78 79-86 87-94 95-102 103-110 Slots Main Frame 11 1 1 1 1 1 1 1 1 1 1 1 1 F75xx LAN Switch 00 1 1 1 1 1 1 2 2 2 2 2 2 option Exp. Frame 01 2 3 4 5 6 7 8 9 10 11 12 13 F7510 LAN Cable 00 2 3 4 5 6 7 8 9 10 11 12 13 LAN Crossed 0 1 0 0 0 0 0 0 0 0 0 0 0 0 Cable Note: This table assumes the main frame and expansion frames have 8 I/O slots (use option V108). 58

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185

I/O Expansion
Note: The number of expansion power supplies that can be cascaded to the power supply
on the main frame is limited. When required, optional DC or AC power supplies should
be installed on the expansion frames to meet the accumulated power consumption and
voltage level requirements.
In the maximal configuration, up to 110 I/Os can be connected to the ACE3600, by using
two expansion Ethernet switches on the main frame and thirteen I/O expansion frames.
See the figure below.
LAN Cable
I/O Rack #6
I/O Rack #2
I/O Rack #1
LAN Cable
LAN Cable
DC
Cable
Main Rack
Main PS (AC/DC)
CPU 3640
Expansion Switch 1
Expansion
PS (DC)
Expansion
Module
Radio/Batt. Chassis
Expansion Switch 2
LAN Cable
I/O Rack #13
I/O Rack #8
I/O Rack #7
LAN Cable
LAN Cable
PS (AC)
Expansion
Module
Communication
Cables
ACE3600 I/O Expansion – Maximal I/O Configuration
The following table shows the various configurations per required number of I/O slots:
Number of I/O
Slots
0-8 9-16 17-23 24-31 32-39
40-47
48-55
56-63
64-70
71-78
79-86
87-94 95-102 103-110
Main Frame
F75xx
1
1
1
1
1
1
1
1
1
1
1
1
1
1
LAN Switch
option
0
0
1
1
1
1
1
1
2
2
2
2
2
2
Exp. Frame
F7510
0
1
2
3
4
5
6
7
8
9
10
11
12
13
LAN Cable
0
0
2
3
4
5
6
7
8
9
10
11
12
13
LAN Crossed
Cable
0
1
0
0
0
0
0
0
0
0
0
0
0
0
Note: This table assumes the main frame and expansion frames have 8 I/O slots (use
option V108).
58