Panasonic AG-HMX100 Operating Instructions - Page 22

[SETUP] Menu (Setup Operation) Screen, Setting the Startup Mode [MODE], WHT

Page 22 highlights

Basic Operation [SETUP] Menu (Setup Operation) Screen When the SETUP button is pressed, the [SETUP] menu screen appears as shown below. The [SETUP] menu is used to make the basic settings for the entire unit. POS. X 128 Y 128 Z 196 EVENT ME TIME 00 E 01:00 F SETUP PATTERN 3021 INT WHT MODE POWER RESET AUDIO INPUT VIDEO SETUP AUX WFM SDI1 SDI1 VIDEO ASPECT SETUP FORMAT 1080/59i - - - - DIRECT PATTERN SETUP BUS TYPE AB MEMORY INT V TITLE 3 3 AUDIO CH L-CH R-CH OSD CH SDI1 1 2 ON AUDIO SOURCE AUX/MIC FADER CP PAIR PAIR AUDIO ALIGN. LEVEL 0dB HEAD dB*1 PC1 FORMAT ANALOG SXGA A.SET ON PC2 H POSI V POSI PHASE CLOCK 30 10 16 1688 GEN. H PHASE LOCK 1000 FILE EMPTY 1 SAVE SYSTEM1 TIME GPI SEC ME SYSTEM2 P.SAVE SCR SAVE OFF 10 HOURS M. OFF RS-232C B.RATE DATA L. PARITY 9.6k 8BITS NONE PJ 3D MODE FORMAT OFF - - Rotary 1 Rotary 2 Rotary 3 Rotary 4 Rotary 5 Scroll the screen to display. *1 20dB (AG-HMX100P) or 18dB (AG-HMX100E) Setting the Startup Mode [MODE] The [MODE] submenu of the [SETUP] menu is used to specify how to reproduce the stored settings when this unit is restarted (startup mode). Rotary 1 Rotary 2 Rotary 3 Rotary 4 Rotary 5 MODE POWER RESET RESET PRESET FACTORY To reset settings other than basic settings to the factory default settings when the unit is restarted Set [POWER] to [RESET] (reset mode) using the rotary 2 control. Settings other than [SETUP] menu settings, direct pattern settings, event memory settings, file settings, and key learn settings are reset to the factory default settings. To reset all settings to the factory default settings when the unit is restarted Reset all settings to the factory default settings. 1 Set [POWER] to [FACTORY] (factory default mode) using the rotary 2 control, and press the key. 2 When the message [OK?] appears, press the key. To cancel the file save, press the holding down the SHIFT key. key while 3 When the message "Please Wait..." appears and then "TURN POWER OFF" appears, turn off the power and restart the unit. To restore the last settings when the unit is restarted Set [POWER] to [PRESET] (preset mode) using the rotary 2 control. The following types of data are stored, and applied when the unit is started next time. • [INT VIDEO] menu setting values • [COLOR EFFECTS], [VIDEO EFFECTS], and [AUDIO EFFECTS] menu setting values • Combinations of patterns registered as direct patterns and numbers • Setting values of effects applied to the patterns registered as direct patterns 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

22
Basic Operation
[SETUP] Menu
(Setup Operation) Screen
When the SETUP button is pressed, the [SETUP] menu
screen appears as shown below.
The [SETUP] menu is used to make the basic settings for
the entire unit.
POS.
MODE
POWER
RESET
AUDIO
INPUT
SETUP
VIDEO
AUX
SDI1
WFM
SDI1
VIDEO
1080/59i
FORMAT
ASPECT
- -
SETUP
- -
DIRECT
SETUP
PATTERN
BUS
TYPE
AB
MEMORY INT V
3
TITLE
3
AUDIO
CH
SDI1
CH
L-CH
1
R-CH
2
OSD
ON
ON
AUDIO
SOURCE
CP PAIR
FADER
AUX/MIC
PAIR
AUDIO
ALIGN.
0dB
LEVEL
HEAD
dB*
1
PC1
ANALOG
FORMAT
SXGA
A.SET
PC2
H POSI
30
V POSI
10
PHASE
16
CLOCK
1688
GEN.
H PHASE
1000
LOCK
FILE
EMPTY
1
SAVE
SYSTEM1 TIME
SEC
GPI
ME
SYSTEM2 P.SAVE
OFF
SCR SAVE
10
HOURS M.
OFF
RS-232C B.RATE
9.6k
DATA L.
8BITS
PARITY
NONE
PJ
3D
MODE
OFF
FORMAT
- -
EVENT
SETUP
ME TIME
PATTERN
INT
00
E
01:00
F
3021
WHT
X
128
Z
196
Y
128
Scroll the screen to display.
Rotary 1
Rotary 2
Rotary 3
Rotary 4
Rotary 5
*
1
20dB (AG-HMX100P) or 18dB (AG-HMX100E)
Setting the Startup Mode [MODE]
The [MODE] submenu of the [SETUP] menu is used to
specify how to reproduce the stored settings when this unit
is restarted (startup mode).
Rotary 1
Rotary 2
Rotary 3
Rotary 4
Rotary 5
RESET
PRESET
FACTORY
MODE
RESET
POWER
To reset settings other than basic
settings to the factory default settings
when the unit is restarted
Set [POWER] to [RESET] (reset mode) using the rotary 2
control.
Settings other than [SETUP] menu settings, direct pattern
settings, event memory settings, file settings, and key learn
settings are reset to the factory default settings.
To reset all settings to the factory default
settings when the unit is restarted
Reset all settings to the factory default settings.
1
Set [POWER] to [FACTORY] (factory default
mode) using the rotary 2 control, and press the
key.
2
When the message [OK?] appears, press the
key.
To cancel the file save, press the
key while
holding down the SHIFT key.
3
When the message “Please Wait…” appears
and then “TURN POWER OFF” appears, turn
off the power and restart the unit.
To restore the last settings when the unit
is restarted
Set [POWER] to [PRESET] (preset mode) using the rotary 2
control.
The following types of data are stored, and applied when
the unit is started next time.
[INT VIDEO] menu setting values
[COLOR EFFECTS], [VIDEO EFFECTS], and [AUDIO
EFFECTS] menu setting values
Combinations of patterns registered as direct patterns
and numbers
Setting values of effects applied to the patterns
registered as direct patterns