TEAC TN-5BB Owners Manual English Francais Espanol Deutsch Italiano Nederlands - Page 8

Dust cover, Notes about record styluses, Changing the cartridge, Attaching the dust cover

Page 8 highlights

Dust cover Attaching the dust cover Dust cover Main unit Hinge 1 Insert the hinges completely into the hinge holders at the left and right ends of the back of the main unit. 2 Align the tops of the hinges with the dust cover hinge holders and insert them. oo Close the dust cover during playback. Since doing this prevents skipping caused by unintended contact and blocks external sound pressure, it makes noise less likely to occur. oo Do not open or close it when a record is playing. Doing so could, for example, cause the stylus to skip. oo Keep it closed whenever possible to keep dust out. Removing the dust cover Hold both edges of the dust cover and lift it slowly to remove it along with the hinges from the unit. Then, remove the hinges from the dust cover. Opening and closing the dust cover Opening Hold the front edge of the dust cover and gently lift it open completely until it stops. The dust cover will stay open in this position. Closing Gently lower the dust cover until it is closed. VV Be careful not to pinch your fingers, for example, when opening and closing the dust cover. 8 Notes about record styluses oo If the stylus becomes bent (damaged), it will no longer be able to accurately trace the groove. Since a bent stylus could also damage records and cause malfunction, handle styluses carefully. oo Always use a commercially-available stylus cleaner to clean a stylus. Use of anything other than a stylus cleaner could damage the stylus. Replacing the stylus If the tip of the stylus becomes worn, not only will it worsen the sound quality, it could also damage records. After about 1000 hours of playback time, replace the stylus with one that we specify. The cartridge installed in the product is an Ortofon 2M Red MM-type cartridge. When used normally, the 2M Red stylus should be replaced about every 1000 hours. Please purchase a commerciallyavailable 2M Red replacement stylus. oo Follow the replacement instructions in the manual of the replacement stylus. ATTENTION oo Since loud noises could suddenly occur, put the unit into standby before changing the stylus. oo Be careful not to hurt your hand or the equipment. oo Be careful not to allow small children to accidentally swal- low styluses. oo Be aware that bent styluses, for example, that result from insufficient customer caution or an outside cause are not covered by the warranty. Changing the cartridge To change the cartridge, first remove the headshell from the tonearm. oo The cartridge installed in the product is an Ortofon 2M Red MM-type cartridge. oo We recommend that you attach the protective cover to the cartridge before proceeding. Headshell Screws Nut (inside the cartridge) Shell leads Cartridge 1 Disconnect the shell lead terminals from the cartridge. 4 Connect the shell lead terminals to the cartridge. oo The signals and colors of the shell leads are shown below. Signal Left channel + Left channel − Right channel + Right channel − Color White Blue Red Green 5 Balance the tonearm and adjust the tracking force. Follow the procedures in "Balancing the tonearm and adjusting the tracking force" on page 5. 2 Loosen the screws and remove the cartridge. 3 Attach the new cartridge and tighten the screws. oo Use screws that are suitable for the cartridge. See the illustration below for the position of the screws when attached. 52.8 ±0.5 mm NOTE To adjust the cartridge attachment position more accurately, follow the procedures in the following "Cartridge alignment (overhang adjustment)" section.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

Changing the cartridge
To change the cartridge, first remove the headshell from the
tonearm.
o
The cartridge installed in the product is an Ortofon 2M Red
MM-type cartridge.
o
We recommend that you attach the protective cover to the
cartridge before proceeding.
Headshell
Cartridge
Shell leads
Screws
Nut
(inside the cartridge)
1
Disconnect the shell lead terminals from
the cartridge.
2
Loosen the screws and remove the
cartridge.
3
Attach the new cartridge and tighten
the screws.
o
Use screws that are suitable for the cartridge.
See the illustration below for the position of the screws
when attached.
52.8 ±0.5 mm
NOTE
To adjust the cartridge attachment position more accu-
rately, follow the procedures in the following “Cartridge
alignment (overhang adjustment)” section.
4
Connect the shell lead terminals to the
cartridge.
o
The signals and colors of the shell leads are shown
below.
Signal
Color
Left channel +
White
Left channel −
Blue
Right channel +
Red
Right channel −
Green
5
Balance the tonearm and adjust the
tracking force.
Follow the procedures in “Balancing the tonearm and
adjusting the tracking force” on page 5.
Dust cover
Attaching the dust cover
Hinge
Main unit
Dust cover
1
Insert the hinges completely into the
hinge holders at the left and right ends
of the back of the main unit.
2
Align the tops of the hinges with the
dust cover hinge holders and insert
them.
o
Close the dust cover during playback. Since doing
this prevents skipping caused by unintended contact
and blocks external sound pressure, it makes noise
less likely to occur.
o
Do not open or close it when a record is playing.
Doing so could, for example, cause the stylus to skip.
o
Keep it closed whenever possible to keep dust out.
Removing the dust cover
Hold both edges of the dust cover and lift it slowly to remove it
along with the hinges from the unit. Then, remove the hinges
from the dust cover.
Opening and closing the dust cover
Opening
Hold the front edge of the dust cover and gently lift it open
completely until it stops.
The dust cover will stay open in this position.
Closing
Gently lower the dust cover until it is closed.
V
Be careful not to pinch your fingers, for
example, when opening and closing the
dust cover.
Notes about record styluses
o
If the stylus becomes bent (damaged), it will no longer
be able to accurately trace the groove. Since a bent stylus
could also damage records and cause malfunction, handle
styluses carefully.
o
Always use a commercially-available stylus cleaner to clean
a stylus. Use of anything other than a stylus cleaner could
damage the stylus.
Replacing the stylus
If the tip of the stylus becomes worn, not only will it worsen
the sound quality, it could also damage records. After about
1000  hours of playback time, replace the stylus with one that
we specify.
The cartridge installed in the product is an Ortofon 2M Red
MM-type cartridge.
When used normally, the 2M Red stylus should be replaced
about every 1000  hours. Please purchase a commercially-
available 2M Red replacement stylus.
o
Follow the replacement instructions in the manual of the
replacement stylus.
ATTENTION
o
Since loud noises could suddenly occur, put the unit into
standby before changing the stylus.
o
Be careful not to hurt your hand or the equipment.
o
Be careful not to allow small children to accidentally swal-
low styluses.
o
Be aware that bent styluses, for example, that result from
insufficient customer caution or an outside cause are not
covered by the warranty.
8