Toshiba DKT3210-SD User Guide - Page 108
Local CO Line Circuit Quick Test, indicator to go dark.
View all Toshiba DKT3210-SD manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 108 highlights
IPT2010-SDC Local CO Line Connection Local CO Line Circuit Quick Test This procedure is a quick test to verify the CO Line connection and correct IPT2010SDC ACO operation. In normal operation the ACO indicator is dark when the ACO line is not in use, red when the ACO is used by another station, and green when the ACO is in use at this station. The ACO indictor that is lit a steady red, when the ACO is not in use, indicates no CO Line connection or a faulty CO Line circuit. Note The IPT2010-SDC does not require a LAN connection for this test. 1. Apply power to the IPT2010-SDC (POE or local AC adapter). The ACO button will LED will be red. 2. Plug in the local CO Line connection. A functional line will cause the ACO indicator to go dark. 3. Lift the handset then, press the ACO button. Verify that the ACO indicator lights green and dial tone is heard. 4. Dial a local telephone number. Verify two-way speech. 5. Place the handset in the IPT2010-SDC and verify that the ACO indicator goes dark. 90 Strata CIX and CTX IPT/DKT Telephone 08/07